The 1794-CE1 is the 0.3 m extender cable that breaks a FLEX I/O backplane and rejoins it, so the island can turn a corner or run in two rows.
One cable per system is enough for the two-row arrangement the selection guide describes; the 1794-CE3 is the 0.9 m version for a wider offset.
| 1794-PS3 | 120/220V AC power supply, 24V DC 3.0 A | IN STOCK |
| 1794-PS13 | 120/220V AC power supply, 24V DC 1.3 A | IN STOCK |
| 1794-CE1 | 0.3 m (1 ft) extender cable for FLEX I/O | IN STOCK |
| 1794-CE3 | 0.9 m (3 ft) extender cable for FLEX I/O | IN STOCK |
| 1794-NM1 | panel mounting kit with 18 screws | IN STOCK |
| 1794-N2 | empty slot filler module, no electronics | IN STOCK |
| 1794-CJC2 | cold junction compensation kit, two parts | IN STOCK |
| 1794-LBL | label kit with die-cut sheet and five labels | IN STOCK |
Application |
FLEX I/O backplane extender cable |
Cat Num |
1794-CE1 |
Brand Name |
Rockwell |
Length |
0.3 m (1 ft) |
Use |
One cable per system, between any modules or adapter and module |
Purpose |
Splits the system into two rows or changes horizontal to vertical |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Separates the backplane at one point and reconnects it with a cable, which is what lets an island wrap a panel.
Install it between any two modules, or between the adapter and the first module.
0.3 m (1 ft) is the short version, for a fold close to the rail.
One extender per system is the guide's recommendation, not one per module.
Horizontal to vertical orientation is the other documented use, letting a run climb beside a duct.
The two rail sections still need 25 mm of air space around them for cooling.
Grounding does not travel through the cable, so each rail section needs its own chassis path.
End caps still close both ends of the split backplane.
Panels with obstructions — a duct, a terminal block, or a door hinge in the rail line.
Two-tier layouts where the second row sits below the first.
Not for long runs; the 1794-CE3 covers 0.9 m.
Not a network cable; this extends the backplane, not the fieldbus.
1794-CE1: 0.3 m (1 ft).
1794-CE3: 0.9 m (3 ft).
One per system in the documented arrangement.
Publication 1794-IN012 covers both cables and the two-row layout diagram.
Compact panels where 0.3 m is enough to clear an obstruction.
Vertical transitions on an existing rail.
Not for multiple splits; one cable per system.
Not for XT thermal extension; the cable does not change a module's temperature rating.
How long is the 1794-CE1?
0.3 m (1 ft).
How many extenders does a system use?
One, per the selection guide.
Where can it be installed?
Between any two modules, or between the adapter and a module.
What is it used for?
Splitting the system into two rows, or changing from horizontal to vertical mounting.
Is there a longer version?
Yes, the 1794-CE3 at 0.9 m (3 ft).
Does it extend the network?
No; it extends the backplane only.
1794-CE1 is a 1794 FLEX I/O 0.3 m flexbus extender cable, described here from the Rockwell FLEX I/O selection guide and the related publication so that the identity, the published rating and the compatibility statement are on the page for this catalog number.
| Specification | Value |
|---|---|
| Catalog number | 1794-CE1, FLEX I/O 1 ft extender cable |
| Length | 0.3 m, 1 ft |
| Function | Connects between any module, or between an adapter and a module, to split the system into two rows or into horizontal and vertical sections |
| Quantity rule | One extender cable per system, never more than one |
| Temperature rating | 0 to 60 degrees C |
| Series | A |
| UPC | 612598129072 |
| Country of origin | China |
| Compatible systems | 1794 FLEX I/O, FLEX Ex I/O, FLEX I/O-XT |
| Source | 1794-SG002D-EN-P selection guide, and the manufacturer product record for the UPC and temperature rating |
Three hundred millimetres of cable is a layout decision rather than a cable purchase. The extender allows the adapter to sit horizontally in a shallow section while the modules sit vertically in a deeper one, and the one cable limit is what keeps that legal.
Sixty degrees C on the cable sets a panel interior limit that can be tighter than the module rating. In a sealed enclosure with poor circulation the cable becomes the first part to be de-rated, and that is a mechanical finding, not an electrical one.
This page states only what the Rockwell FLEX I/O documentation publishes for 1794-CE1: the catalog identity, the published rating or dimension, the compatibility statement and the source publication. Where the manufacturer does not publish a figure, the page says so instead of estimating one.
Temperature ratings on a passive accessory are inherited from the materials. A cable rated to sixty degrees limits the panel interior temperature just as firmly as a module rated to fifty five, and a hot enclosure will fail the cable before it fails the electronics.
Every accessory on this page is sourced from the same FLEX selection guide that specifies the adapters and the terminal bases, which means the compatibility statement is the manufacturer statement rather than a distributor inference.
Panel mounting without DIN rail is a common requirement in machine tools exported to regions where the rail is not standard, and the mounting kit with its screws is cheaper than a rail plus the labour to fit it.
A filler is not a spare slot. Some integrators install a filler to reserve capacity for a later expansion, and that works only if the adapter was sized for the eventual module count at commissioning time, not at expansion time.
The extender cable rule is one per system, not one per row. A second extender in series breaks the flexbus timing assumptions the adapter was designed around, so the two row layout is a one cable layout, and a three row layout is not supported at all.
Labels matter more than they look. A terminal base that is not marked with its slot and its module type turns every future maintenance visit into a wire tracing exercise, which is exactly what the label kit exists to prevent.
Accessory part numbers are frequently the difference between a system that ships and a system that waits. A missing extender cable is a one week delay on a panel that is otherwise complete, and the order of magnitude of that delay belongs in the planning conversation.
A dummy filler module exists because an empty terminal base is an open slot in the flexbus chain. The filler carries no electronics, and its whole job is mechanical and documentation: the rail is complete, the slot is accounted for, and the drawing shows an intentional gap rather than a missing part.
Country of origin and part number structure belong on the page because procurement asks. A conformally coated variant and a standard variant share the same mechanical drawing and differ in the suffix, which is the kind of detail that only shows up at goods receipt.
Accessories are where a FLEX system stops being a catalog page and becomes a panel. The rail, the extender cable, the mounting screws and the filler module all change the drawing, and none of them appear in the module data sheet that the integrator reads first.
Screws in a mounting kit are a count, not a suggestion. Two for the adapter and two for each module means the kit covers a full eight module group, and a ninth module requires either a second kit or a sourced screw, which is a purchasing detail worth stating.
The flexbus connector is the fragile part of the assembly. It is pushed to the left to connect and retracted to disconnect, and a base installed with the connector partly extended will produce intermittent I/O that survives a power cycle and reappears under vibration.
A right angle split between horizontal and vertical orientation is the real reason the extender exists. Mounting the adapter horizontally in a shallow enclosure and the modules vertically in a deeper section is a mechanical decision that the cable makes possible without a second adapter.
One cable per system, sized to the mechanical split between the two sections, and a panel interior that stays under sixty degrees C.
Related models, options and spare parts for this range are listed in the Allen-Bradley Flex I/O 1794 modules category.