|
Product Details:
Payment & Shipping Terms:
|
The 1794-CE1 is the 0.3 m extender cable that breaks a FLEX I/O backplane and rejoins it, so the island can turn a corner or run in two rows.
One cable per system is enough for the two-row arrangement the selection guide describes; the 1794-CE3 is the 0.9 m version for a wider offset.
| 1794-PS3 | 120/220V AC power supply, 24V DC 3.0 A | IN STOCK |
| 1794-PS13 | 120/220V AC power supply, 24V DC 1.3 A | IN STOCK |
| 1794-CE1 | 0.3 m (1 ft) extender cable for FLEX I/O | IN STOCK |
| 1794-CE3 | 0.9 m (3 ft) extender cable for FLEX I/O | IN STOCK |
| 1794-NM1 | panel mounting kit with 18 screws | IN STOCK |
| 1794-N2 | empty slot filler module, no electronics | IN STOCK |
| 1794-CJC2 | cold junction compensation kit, two parts | IN STOCK |
| 1794-LBL | label kit with die-cut sheet and five labels | IN STOCK |
Application |
FLEX I/O backplane extender cable |
Cat Num |
1794-CE1 |
Brand Name |
Rockwell |
Length |
0.3 m (1 ft) |
Use |
One cable per system, between any modules or adapter and module |
Purpose |
Splits the system into two rows or changes horizontal to vertical |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Separates the backplane at one point and reconnects it with a cable, which is what lets an island wrap a panel.
Install it between any two modules, or between the adapter and the first module.
0.3 m (1 ft) is the short version, for a fold close to the rail.
One extender per system is the guide's recommendation, not one per module.
Horizontal to vertical orientation is the other documented use, letting a run climb beside a duct.
The two rail sections still need 25 mm of air space around them for cooling.
Grounding does not travel through the cable, so each rail section needs its own chassis path.
End caps still close both ends of the split backplane.
Panels with obstructions — a duct, a terminal block, or a door hinge in the rail line.
Two-tier layouts where the second row sits below the first.
Not for long runs; the 1794-CE3 covers 0.9 m.
Not a network cable; this extends the backplane, not the fieldbus.
1794-CE1: 0.3 m (1 ft).
1794-CE3: 0.9 m (3 ft).
One per system in the documented arrangement.
Publication 1794-IN012 covers both cables and the two-row layout diagram.
Compact panels where 0.3 m is enough to clear an obstruction.
Vertical transitions on an existing rail.
Not for multiple splits; one cable per system.
Not for XT thermal extension; the cable does not change a module's temperature rating.
How long is the 1794-CE1?
0.3 m (1 ft).
How many extenders does a system use?
One, per the selection guide.
Where can it be installed?
Between any two modules, or between the adapter and a module.
What is it used for?
Splitting the system into two rows, or changing from horizontal to vertical mounting.
Is there a longer version?
Yes, the 1794-CE3 at 0.9 m (3 ft).
Does it extend the network?
No; it extends the backplane only.