The 1794-ACNR15 carries two BNC connectors instead of one, so the FLEX I/O island can sit on a redundant ControlNet media pair rather than a single segment.
Connector B exists only on the R variants — that is the whole mechanical difference between this and the 1794-ACN15, plus the Comm B indicator.
| 1794-AENT | EtherNet/IP adapter, single RJ45, 8 modules | IN STOCK |
| 1794-AENTR | dual-port EtherNet/IP adapter, redundancy capable | IN STOCK |
| 1794-AENTRXT | dual-port EtherNet/IP adapter, extended temperature | IN STOCK |
| 1794-ACN15 | ControlNet adapter, 5 Mbps, 8 modules | IN STOCK |
| 1794-ACN15K | ControlNet adapter, 5 Mbps, conformal coated | IN STOCK |
| 1794-ACNR | ControlNet adapter with redundant media | IN STOCK |
| 1794-ACNR15XT | ControlNet adapter, redundant media, extended temperature | IN STOCK |
| 1794-ACN | ControlNet adapter module, 8 modules | IN STOCK |
| 1794-ADN | DeviceNet adapter, 8 modules | IN STOCK |
| 1794-ADNK | DeviceNet adapter, conformal coated | IN STOCK |
| 1794-APB | Profibus DP adapter, 8 modules | IN STOCK |
| 1794-APBDPV1 | Profibus DP-V1 adapter, 8 modules | IN STOCK |
| 1794-ASB | Remote I/O adapter, 8 modules | IN STOCK |
| 1794-ASB2 | Remote I/O adapter, extended functionality | IN STOCK |
| 1794-ASBLT | Remote I/O adapter with built-in termination | IN STOCK |
Application |
FLEX I/O redundant ControlNet adapter |
Cat Num |
1794-ACNR15 (listed as 1794-ACNR) |
Brand Name |
Rockwell |
I/O module capacity |
8 modules |
ControlNet connectors |
2 x BNC (A and B) |
Supply voltage, input |
19.2...31.2V DC, 400 mA |
Supply voltage, output |
5V DC, 640 mA |
Inrush current |
14 A for 2 ms |
Communication rate |
5 Mbps |
Dimensions |
87.4 x 94 x 92 mm |
Operating temperature |
-25...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
BNC connector A and BNC connector B, with Comm A and Comm B indicators.
Both cables run to the same node address, so the island is one ControlNet node on two media paths.
5 Mbps, 8 modules, the same capacity and rate as the single-media adapter.
Belden RG-6/U cable is the specified ControlNet medium.
19.2...31.2V DC at 400 mA for the adapter itself.
5V DC 640 mA output feeding the Flexbus.
14 A for 2 ms inrush, which sets the supply's short-circuit capability.
22...12 AWG single or 22...16 AWG double wire at 105 deg C rating, 0.8 N*m torque.
87.4 x 94 x 92 mm, 220 g, with a locking tab onto 35 mm DIN rail.
-25...55 deg C operating, 55 deg C maximum ambient.
30 g operating shock, 5 g vibration at 10...500 Hz.
Programming terminal NAP port on the faceplate.
Media redundancy on ControlNet where a cable break must not drop the island.
Series C replacement in panels already wired for two BNCs.
Not extended temperature; the 1794-ACNR15XT covers -25...70 deg C.
Not EtherNet/IP.
Two-cable ControlNet segments.
Critical I/O islands with documented redundancy.
Not a single-BNC drop-in where only one cable exists.
Not for DeviceNet.
How many BNC connectors has the 1794-ACNR15?
Two, connectors A and B, for redundant media.
How many modules can it carry?
8 FLEX I/O modules.
What is the supply requirement?
19.2...31.2V DC at 400 mA with 14 A inrush for 2 ms.
What is the data rate?
5 Mbps ControlNet.
What is the operating temperature?
-25...55 deg C, or -25...70 deg C for the XT version.
What is the Flexbus output?
5V DC at 640 mA.
All values on this page are taken from Rockwell Automation publications 1794-IN101 (Series B) and 1794-IN128F-EN-P (Series D) for the FLEX I/O ControlNet adapter modules. Where the two series differ, both figures are shown rather than merged.
This page covers the redundant-media ControlNet adapter, which Rockwell catalogues as 1794-ACNR15 and which this listing shortens to ACNR. The hardware difference from the single adapter is one extra BNC port: connector A and connector B sit side by side on the front, and both are populated when the slice is wired for media redundancy.
Redundant media is not redundant nodes. The adapter still holds one node address (01...99) and one connection to the controller; the second cable carries the same network traffic over a second physical path, so a broken trunk, a bad tap or a damaged cable does not take the slice off the network. That distinction matters at specification time, because a project that asks for redundant adapters is usually asking for redundant cable, not for a second node.
There is no isolation between the two ControlNet channels. The publication states this explicitly, which means the two segments share a reference and a fault that couples onto both cables is not separated by the adapter. Isolation exists between power, ControlNet and the backplane, at 50 V continuous with an 860 V AC type test for 60 s on Series D hardware.
The LED set is the diagnostic advantage of this part: Comm A and Comm B report independently, so flashing red/off on one channel with solid green on the other is a cable fault or a redundancy warning on that path, while flashing red/green on both is a bad network configuration. A duplicate node address shows as red/off alternating on both channels at once, before the controller ever sees the adapter.
Environmentally the ACNR15 is the standard-temperature part: -25...+55 °C operating and 55 °C maximum surrounding air. If the cabinet runs hotter than that, the same redundant function is available as the 1794-ACNR15XT at -25...+70 °C rather than by derating the standard unit.
Wiring practice is identical to the single adapter: -V common on C, +V DC on D, pass-through of -V on E and +V on F, 0.8 N*m (7 lb-in) torque, 22...12 AWG single conductor, 10 m maximum power run on Series D, 2 conductors maximum on any terminal.
For Zone 2 installations the redundant adapters carry more certification than the single unit: ATEX LCIE 01 ATEX 6020 X plus DEMKO 14 ATEX 1342501X, and IECEx UL 14.0066 (the IECEx listing applies to ACNR15 and ACNR15XT only).
| Attribute | Value |
| I/O capacity | 8 FLEX I/O modules on the backplane |
| Input power | 19.2...31.2 V DC, 400 mA (Series D) / 450 mA maximum, 330 mA at 24 V (Series B) |
| Backplane output | 5 V DC, 640 mA maximum |
| Inrush | 14 A for 2 ms (Series D); 23 A for 2 ms (Series B) |
| Communication rate | 5 Mbps ControlNet |
| Isolation | 50 V continuous, basic insulation; type tested 860 V AC for 60 s power to system, power to ControlNet and ControlNet to system (Series D). No isolation between ControlNet channels. |
| Power dissipation | 3.4 W maximum at 19.2 V DC (Series D); 4.6 W maximum at 19.2 V DC (Series B) |
| Terminal torque | 0.8 N*m (7 lb-in) on terminals C, D, E, F |
| Wire size | Single wire 0.33...2.5 mm2 (22...12 AWG); double wire 0.33...1.3 mm2 (22...16 AWG, not intermixed); 75 °C rated, 1.2 mm insulation maximum |
| Dimensions | 87.4 x 94 x 92 mm (3.44 x 3.7 x 3.6 in.), Series D; 87 x 94 x 69 mm (3.4 x 3.7 x 2.7 in.), Series B |
| Weight | 220 g (7.76 oz) |
| Operating temperature | -25...+55 °C for 1794-ACN15 and 1794-ACNR15; -25...+70 °C for 1794-ACNR15XT |
Mounting follows the same sequence as the terminal bases: hook the rear lip on a 35 x 7.5 x 1 mm top-hat rail (199-DR1 / EN 50022), rotate onto the rail, press down until the locking tab snaps, then push the Flexbus connector into the adapter. The first terminal base hooks into the notch on the right rear of the adapter, and that mechanical link is what keeps the backplane connection from opening under vibration.
Panel or wall mounting uses the 1794-NM1 mounting kit, covered by a separate installation instruction rather than by the adapter publication.
Catalog-name note: Rockwell also lists a legacy 1794-ACNR that predates this adapter, with its own installation instruction 1794-IN018, a 5 Mbps ControlNet v1.25 interface, 400 mA from an external 24 V supply, and a 0.8...1.01 N*m (7...9 in-lb) terminal torque range. Dimensions separate the generations: the legacy single-media 1794-ACN is 87 x 69 x 69 mm, the legacy redundant 1794-ACNR is 87 x 94 x 69 mm, and the 1794-ACNR15 on this page is 87 x 94 x 92 mm. Both redundant parts carry two BNC ports, so a spare pulled from an older bill of materials can be either generation even though the port count matches.
Browse the Allen-Bradley Flex I/O 1794 modules category for the other models, options and spare parts that share this range.