logo
Home ProductsAB FlexLogix I/O 1794

Allen Bradley PLC 1794-ACNR / 1794-ACNR

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1794-ACNR / 1794-ACNR

China Allen Bradley PLC 1794-ACNR / 1794-ACNR supplier
Allen Bradley PLC 1794-ACNR / 1794-ACNR supplier Allen Bradley PLC 1794-ACNR / 1794-ACNR supplier Allen Bradley PLC 1794-ACNR / 1794-ACNR supplier Allen Bradley PLC 1794-ACNR / 1794-ACNR supplier Allen Bradley PLC 1794-ACNR / 1794-ACNR supplier Allen Bradley PLC 1794-ACNR / 1794-ACNR supplier

Large Image :  Allen Bradley PLC 1794-ACNR / 1794-ACNR

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-ACNR / 1794-ACNR

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $985.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1794-ACNR technical data PDF download 1794-ACNR15 / 1794ACNR15 Redundant ControlNet Adapter

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-ACNR15 carries two BNC connectors instead of one, so the FLEX I/O island can sit on a redundant ControlNet media pair rather than a single segment.

Connector B exists only on the R variants — that is the whole mechanical difference between this and the 1794-ACN15, plus the Comm B indicator.

1794-AENT EtherNet/IP adapter, single RJ45, 8 modules IN STOCK
1794-AENTR dual-port EtherNet/IP adapter, redundancy capable IN STOCK
1794-AENTRXT dual-port EtherNet/IP adapter, extended temperature IN STOCK
1794-ACN15 ControlNet adapter, 5 Mbps, 8 modules IN STOCK
1794-ACN15K ControlNet adapter, 5 Mbps, conformal coated IN STOCK
1794-ACNR ControlNet adapter with redundant media IN STOCK
1794-ACNR15XT ControlNet adapter, redundant media, extended temperature IN STOCK
1794-ACN ControlNet adapter module, 8 modules IN STOCK
1794-ADN DeviceNet adapter, 8 modules IN STOCK
1794-ADNK DeviceNet adapter, conformal coated IN STOCK
1794-APB Profibus DP adapter, 8 modules IN STOCK
1794-APBDPV1 Profibus DP-V1 adapter, 8 modules IN STOCK
1794-ASB Remote I/O adapter, 8 modules IN STOCK
1794-ASB2 Remote I/O adapter, extended functionality IN STOCK
1794-ASBLT Remote I/O adapter with built-in termination IN STOCK

Product Specifications 1794-ACNR (PDF)
 Application
 FLEX I/O redundant ControlNet adapter
 Cat Num
 1794-ACNR15 (listed as 1794-ACNR)
 Brand Name
 Rockwell
 I/O module capacity
 8 modules
 ControlNet connectors
 2 x BNC (A and B)
 Supply voltage, input
 19.2...31.2V DC, 400 mA
 Supply voltage, output
 5V DC, 640 mA
 Inrush current
 14 A for 2 ms
 Communication rate
 5 Mbps
 Dimensions
 87.4 x 94 x 92 mm
 Operating temperature
 -25...55 deg C

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-ACNR original product photograph, wide view 1794-ACNR original product photograph, wide view 1794-ACNR original product photograph, wide view

Redundant media

BNC connector A and BNC connector B, with Comm A and Comm B indicators.

Both cables run to the same node address, so the island is one ControlNet node on two media paths.

5 Mbps, 8 modules, the same capacity and rate as the single-media adapter.

Belden RG-6/U cable is the specified ControlNet medium.

Power

19.2...31.2V DC at 400 mA for the adapter itself.

5V DC 640 mA output feeding the Flexbus.

14 A for 2 ms inrush, which sets the supply's short-circuit capability.

22...12 AWG single or 22...16 AWG double wire at 105 deg C rating, 0.8 N*m torque.

Mechanical

87.4 x 94 x 92 mm, 220 g, with a locking tab onto 35 mm DIN rail.

-25...55 deg C operating, 55 deg C maximum ambient.

30 g operating shock, 5 g vibration at 10...500 Hz.

Programming terminal NAP port on the faceplate.

Application

Media redundancy on ControlNet where a cable break must not drop the island.

Series C replacement in panels already wired for two BNCs.

Not extended temperature; the 1794-ACNR15XT covers -25...70 deg C.

Not EtherNet/IP.

Where it fits

Two-cable ControlNet segments.

Critical I/O islands with documented redundancy.

Not a single-BNC drop-in where only one cable exists.

Not for DeviceNet.

FAQ — 1794-ACNR

How many BNC connectors has the 1794-ACNR15?

Two, connectors A and B, for redundant media.

How many modules can it carry?

8 FLEX I/O modules.

What is the supply requirement?

19.2...31.2V DC at 400 mA with 14 A inrush for 2 ms.

What is the data rate?

5 Mbps ControlNet.

What is the operating temperature?

-25...55 deg C, or -25...70 deg C for the XT version.

What is the Flexbus output?

5V DC at 640 mA.


Data sources. Technical values on this page come from Rockwell publication 1794-IN128 (FLEX I/O ControlNet Adapters). Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1794-ACNR15: FLEX I/O ControlNet adapter, redundant media

All values on this page are taken from Rockwell Automation publications 1794-IN101 (Series B) and 1794-IN128F-EN-P (Series D) for the FLEX I/O ControlNet adapter modules. Where the two series differ, both figures are shown rather than merged.

This page covers the redundant-media ControlNet adapter, which Rockwell catalogues as 1794-ACNR15 and which this listing shortens to ACNR. The hardware difference from the single adapter is one extra BNC port: connector A and connector B sit side by side on the front, and both are populated when the slice is wired for media redundancy.

Redundant media is not redundant nodes. The adapter still holds one node address (01...99) and one connection to the controller; the second cable carries the same network traffic over a second physical path, so a broken trunk, a bad tap or a damaged cable does not take the slice off the network. That distinction matters at specification time, because a project that asks for redundant adapters is usually asking for redundant cable, not for a second node.

There is no isolation between the two ControlNet channels. The publication states this explicitly, which means the two segments share a reference and a fault that couples onto both cables is not separated by the adapter. Isolation exists between power, ControlNet and the backplane, at 50 V continuous with an 860 V AC type test for 60 s on Series D hardware.

The LED set is the diagnostic advantage of this part: Comm A and Comm B report independently, so flashing red/off on one channel with solid green on the other is a cable fault or a redundancy warning on that path, while flashing red/green on both is a bad network configuration. A duplicate node address shows as red/off alternating on both channels at once, before the controller ever sees the adapter.

Environmentally the ACNR15 is the standard-temperature part: -25...+55 °C operating and 55 °C maximum surrounding air. If the cabinet runs hotter than that, the same redundant function is available as the 1794-ACNR15XT at -25...+70 °C rather than by derating the standard unit.

Wiring practice is identical to the single adapter: -V common on C, +V DC on D, pass-through of -V on E and +V on F, 0.8 N*m (7 lb-in) torque, 22...12 AWG single conductor, 10 m maximum power run on Series D, 2 conductors maximum on any terminal.

For Zone 2 installations the redundant adapters carry more certification than the single unit: ATEX LCIE 01 ATEX 6020 X plus DEMKO 14 ATEX 1342501X, and IECEx UL 14.0066 (the IECEx listing applies to ACNR15 and ACNR15XT only).

Specifications printed by Rockwell

AttributeValue
I/O capacity8 FLEX I/O modules on the backplane
Input power19.2...31.2 V DC, 400 mA (Series D) / 450 mA maximum, 330 mA at 24 V (Series B)
Backplane output5 V DC, 640 mA maximum
Inrush14 A for 2 ms (Series D); 23 A for 2 ms (Series B)
Communication rate5 Mbps ControlNet
Isolation50 V continuous, basic insulation; type tested 860 V AC for 60 s power to system, power to ControlNet and ControlNet to system (Series D). No isolation between ControlNet channels.
Power dissipation3.4 W maximum at 19.2 V DC (Series D); 4.6 W maximum at 19.2 V DC (Series B)
Terminal torque0.8 N*m (7 lb-in) on terminals C, D, E, F
Wire sizeSingle wire 0.33...2.5 mm2 (22...12 AWG); double wire 0.33...1.3 mm2 (22...16 AWG, not intermixed); 75 °C rated, 1.2 mm insulation maximum
Dimensions87.4 x 94 x 92 mm (3.44 x 3.7 x 3.6 in.), Series D; 87 x 94 x 69 mm (3.4 x 3.7 x 2.7 in.), Series B
Weight220 g (7.76 oz)
Operating temperature-25...+55 °C for 1794-ACN15 and 1794-ACNR15; -25...+70 °C for 1794-ACNR15XT

Installation facts that decide field failures

  • Backplane. The adapter is the head of the slice: its Flexbus connector drives up to eight terminal bases, and the base hook on the right rear of the adapter has to engage the notch on the first base or the backplane connection is not mechanically locked.
  • Node address. Node addressing is set on the two-dial switch, valid range 01...99. The dials are read by RSNetWorx for ControlNet; a duplicate address shows up as the Comm A and Comm B LEDs flashing red/off alternately, not as a comms failure on one channel.
  • Field power. Field power lands on terminals C (-V common, upper connector) and D (+V DC, lower connector); E and F pass -V common and +V DC to the next module in the series. Series D limits the power wiring run to 10 m (32.8 ft); the earlier Series B publication stated 3 m (9.8 ft), so a panel wired to the older limit is still inside specification.
  • Grounding. Grounding is through the DIN rail: the rail must be zinc-plated chromate-passivated steel, secured about every 200 mm, with end anchors, because the adapter has no separate chassis terminal.
  • Indicators. The Status LED tells the maintenance story: off means no power, flashing green means on-line but not connected, solid green means connected, flashing red means an I/O module was removed or a wrong module was inserted or a flash update is in progress, solid red means adapter failure.
  • Supply source. Series D adds an electrical safety requirement that the earlier publication does not state: the 24 V source feeding the adapter and all connected I/O must be a SELV or PELV supply approved to EN/IEC 60950-1, EN/IEC 61010-2-201 or EN/IEC 62368-1, and the field wiring must follow the applicable installation code such as NEC article 501-4(b) in Class I locations.
  • Hazardous area. Zone 2 use requires an enclosure of at least IP54, pollution degree 2, transient excursions held to 140% of the peak rated voltage, and the ATEX marking II 3G Ex nA IIC T4 Gc (LCIE 01 ATEX 6020 X). The redundant adapters also carry DEMKO 14 ATEX 1342501X and IECEx UL 14.0066.

Mounting follows the same sequence as the terminal bases: hook the rear lip on a 35 x 7.5 x 1 mm top-hat rail (199-DR1 / EN 50022), rotate onto the rail, press down until the locking tab snaps, then push the Flexbus connector into the adapter. The first terminal base hooks into the notch on the right rear of the adapter, and that mechanical link is what keeps the backplane connection from opening under vibration.

Panel or wall mounting uses the 1794-NM1 mounting kit, covered by a separate installation instruction rather than by the adapter publication.

Catalog-name note: Rockwell also lists a legacy 1794-ACNR that predates this adapter, with its own installation instruction 1794-IN018, a 5 Mbps ControlNet v1.25 interface, 400 mA from an external 24 V supply, and a 0.8...1.01 N*m (7...9 in-lb) terminal torque range. Dimensions separate the generations: the legacy single-media 1794-ACN is 87 x 69 x 69 mm, the legacy redundant 1794-ACNR is 87 x 94 x 69 mm, and the 1794-ACNR15 on this page is 87 x 94 x 92 mm. Both redundant parts carry two BNC ports, so a spare pulled from an older bill of materials can be either generation even though the port count matches.