1784-CP6 is the complete DH+ programming cable for the 1784-KT, -KT2 and -KL interface cards: card connector on one end, PLC-5 DH+ plug on the other, no adapter needed.
Length is 10 ft (3.05 m), slightly shorter than the PCM family leads.
| 1784-U2DN | USB to DeviceNet adapter, PCMCIA-era replacement | IN STOCK |
| 1784-U2CN | USB to ControlNet adapter cable | IN STOCK |
| 1784-SD2 | Industrial 2 GB Secure Digital card | IN STOCK |
| 1784-SD1 | Industrial 1 GB Secure Digital card | IN STOCK |
| 1784-PKTXD | DH+ / RIO / DH-485 dual channel PCI card | IN STOCK |
| 1784-PKTCS | ControlNet 1.5 PC card | IN STOCK |
| 1784-PCM6 | DH+ cable, 8-pin mini-DIN | IN STOCK |
| 1784-PCM5 | PLC-5 / PCMCIA DH+ cable | IN STOCK |
| 1784-PCM4 | DH-485 cable for SLC 5/01 to 5/03 | IN STOCK |
| 1784-PCM2 | PLC-2 cable for the PCMK card | IN STOCK |
| 1784-PCIDS | DeviceNet PCI scanner card | IN STOCK |
| 1784-PCICS | ControlNet PCI scanner card | IN STOCK |
| 1784-PCIC | ControlNet PCI card, redundant media | IN STOCK |
| 1784-PCD1 | DeviceNet PCMCIA interface cable | IN STOCK |
| 1784-PCC1 | ControlNet PCMCIA interface cable | IN STOCK |
| 1784-CP8 | 62-pin D-shell to 3-pin Phoenix adapter | IN STOCK |
| 1784-CP7 | CP / CP5 to PLC-5 DIN adapter | IN STOCK |
| 1784-CP6 | KT / KT2 / KL to PLC-5 cable, 3.05 m | IN STOCK |
| 1784-CP14 | DH-485 cable, Phoenix to RJ45, 3.2 m | IN STOCK |
| 1784-CP11 | PLC-5 serial programming cable | IN STOCK |
| 1784-CP10 | PLC-5 serial programming cable | IN STOCK |
| 1784-CP | PLC-3 communication cable | IN STOCK |
Catalog number |
1784-CP6 |
Product type |
PLC-5 communication cable |
Used with |
1784-KT, 1784-KT2, 1784-KL interface cards |
Length |
10 ft (3.05 m) |
Lifecycle status |
Discontinued October 18, 2019 |
Replacement category |
Engineering Replacement |
Country of origin |
United States of America |
Warranty |
1 year |
Publication |
1784-TD029 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1784-TD029 (module specifications) and 1784-TD029 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
1784-CP6 is the complete DH+ programming cable for the 1784-KT, -KT2 and -KL interface cards: card connector on one end, PLC-5 DH+ plug on the other, no adapter needed.
That makes it the simpler alternative to CP plus CP7 — one part instead of two, which is why it is worth having when a kit is being rebuilt.
Rockwell's cable tables note that CP6 can replace a CP cable when connecting a computer to a communication interface daughterboard, so the two are alternatives rather than additions.
Discontinued October 18, 2019, replacement category Engineering Replacement.
The interface cards it serves are long withdrawn, so this cable's market is the installed base and its spares shelf.
Programming PLC-5 processors from a desktop with a KT, KT2 or KL card — the classic factory-floor programming station of the 1990s.
Rebuilding that station where the card survives and the cable does not.
Check both connector shells and run a continuity test end to end; a 3 m lead is easy to ring out with a meter.
Ask which card it was used with — KT, KT2 or KL — since the card-end connector differs between them.
What does 1784-CP6 connect?
1784-CP6 is the complete DH+ programming cable for the 1784-KT, -KT2 and -KL interface cards: card connector on one end, PLC-5 DH+ plug on the other, no adapter needed.
Is 1784-CP6 still available from Rockwell?
No. Discontinued October 18, 2019; replacement category Engineering Replacement.
What replaces 1784-CP6?
Rockwell names no stocked successor; the Engineering Replacement category covers support case by case.
Where does 1784-CP6 sit in the system?
Programming PLC-5 processors from a desktop with a KT, KT2 or KL card — the classic factory-floor programming station of the 1990s.
What should I check before buying 1784-CP6?
Both connector shells and end-to-end continuity.
1784-CP6
This page documents catalog number 1784-CP6, a 1784 DH-485 / Data Highway Plus programming accessory, as published by Rockwell Automation in the installation data sheets and processor manuals cited in the table. Every value below comes from those documents; nothing is inferred.
| Specification | Value |
|---|---|
| Function | Programming cable from a 1784-KT series communication interface card to an enhanced PLC-5 processor |
| Card-side connector | 62-pin D-shell, secured with captive screws |
| Processors served | PLC-5/11, -5/20, -5/30, -5/40, -5/60, -5/80 and PLC-5/VME (1784-V40) |
| Alternative connection | 1784-CP cable plus 1784-CP7 adapter reaches the same processors |
| Publication referenced by the card manual | 1784-2.26 |
| Network served | Data Highway Plus |
| Cable length | Not published in the documents retrieved for this page |
Three things have to line up before this part does any work: the connector at the computer or card end, the connector at the processor end, and the processor family the cable was published for. The table above states all three wherever the source documents state them. Where a document is silent, the row says so rather than carrying a plausible substitute, because a plausible substitute in a cable table is how a wrong part gets ordered.
These cables were published for a generation of computers that no longer exists in most plants. What survives is the processor, so the practical question is usually whether the cable can be used with a current PC through a converter. The answer depends on the pin mapping at the computer end, which is why the connector type is stated rather than left to a photograph.
These cables were published for a generation of computers that no longer exists in most plants. What survives is the processor, so the practical question is usually whether the cable can be used with a current PC through a converter. The answer depends on the pin mapping at the computer end, which is why the connector type is stated rather than left to a photograph.
The processor list is the specification that matters most on this page, because a programming cable is bought against a processor rather than against a network. A cable that reaches a PLC-5/25 does not reach a PLC-5/40 without the adapter that the manual names, and the two part numbers are easy to confuse at a distributor's counter.
Only values that appear in the cited Rockwell Automation publications are printed here. Cable length is listed only where the document states it; a length that is not published is marked as not published rather than taken from a distributor listing. Where two Rockwell publications describe the same catalog number differently, both statements are shown with their source, and no attempt is made to decide between them. Pin-level wiring is not reproduced on this page: it belongs to the publication for the specific cable, and a supplier page is not the right place to reconstruct it.
The processors named on this page are the ones the cable was published for, and the list is narrow on purpose. A cable built for a PLC-5 serial port does not serve a PLC-2 program panel connector, and the DH+ cables do not serve a DH-485 port even though both are eight-pin round connectors on some processors. Compatibility is a published statement, and a page that repeats it saves a purchase order that would otherwise be returned.
An obsolete cable still has a function in a plant that has not migrated: it keeps a processor programmable. The economics are simple, because the alternative is an interface upgrade that touches the network, the software and the procedures. What the plant needs from the supplier is certainty about which catalog number fits which processor, and that certainty comes from the compatibility table rather than from a photograph.
Serial programming on these processors is a null modem connection in the physical sense: transmit crosses to receive and the handshake lines are strapped. A cable wired straight through will not communicate, and no amount of port configuration will fix it. When a site has lost the original cable and a substitute is being made, the pin mapping has to come from the publication for the specific cable rather than from a generic serial diagram, because the processor side uses a different pin count and a different strapping pattern.
Where a plant still programs a PLC-5 or an SLC from a laptop, the practical replacement path is a modern interface rather than a rebuilt cable. That path needs the same information this page carries: which port on the processor, which protocol, and what the original cable did. Keeping the original catalog number in the maintenance record is what allows that decision to be made later without pulling a panel apart to look at a connector.
Where the same catalog number turns up with a different connector count in two Rockwell publications, the honest answer is that both statements exist. One document describes the packing data for the cable, the other describes its use with a terminal family, and the difference is usually a revision rather than an error. Declaring both, with the publication each came from, is better than choosing one and being wrong for half the installed base.
The difference between a 9-pin and a 25-pin serial connector on the computer end is not cosmetic. It decides which vintage of PC the cable was made for, and a cable built for a 25-pin port will not fit a 9-pin port without an adapter whose pin mapping has to be checked. Because both cables carry the same PLC-side connector, a spare ordered by catalog number is the only reliable way to get the right combination of ends.
Cable length limits on these networks are published as a distance at a given data rate, not as a maximum cable length for the cable itself. The 10,000 ft figure at 57.6 kbaud for a DH+ link through an ISA card is a network figure that includes every node and every drop, so a longer cable does not buy a longer network. Reading the figure as a cable specification is a common mistake that shows up as intermittent faults at one end of a long trunk.
A DH-485 link built with a programming cable is a temporary connection, and treating it as permanent is how cabinets end up with a programming port hanging inside a live enclosure. The cable is not rated for continuous flexing, its connector is not a field-installable network connector, and the card it serves expects to be inside a computer that is switched off before the cable is removed.
A programming cable is the part of a control system that survives longest and gets documented least. The card it plugs into is obsolete, the software that used it is obsolete, and the cable itself is still in a drawer because it was never thrown away. That is exactly why the connector types and the compatible processor list belong on a product page: the person looking for one of these is usually matching a cable to a processor that is already running, not designing a new network.
Termination on a DH+ or DH-485 link is a property of the physical ends of the trunk, and the cable at the programming end sometimes carries a switchable resistor for exactly that reason. A programming cable with the resistor switched in, left connected to a network that is already terminated at both ends, adds a third termination and degrades the signal. The switch is there to be set for the situation, not left in the position it arrived in.
Documentation for these parts predates the web. Several of the installation data sheets were published in the early 1990s and are still the only authoritative source for connector types and processor compatibility. That is why the publication numbers are quoted on this page: an engineer verifying a claim can go to the document rather than to a distributor's description, and the two do not always agree.
The processors these cables serve are still in production in plenty of plants, and the cable is the weakest link in the chain that keeps them programmable. Publishing the connector types, the processor list and the publication number turns a cable into a documented part; leaving those out leaves a buyer comparing photographs on distributor sites and hoping the pin count matches.
Adapters exist because one card family has to reach several processor generations. The adapter carries the pin remapping and sometimes the termination, so pairing the wrong adapter with a cable produces a physical connection that appears correct and does not communicate on the network. The published pairing tables in the processor manuals are the authority here, and they name the cable and the adapter as a pair rather than as interchangeable parts.
Programming cables are handled far more often than any other part in a control panel, because they are plugged and unplugged every time somebody needs to look at a program. The failure mode is therefore mechanical: a bent shell, a cracked Phoenix connector, a broken latch. A spare kept in the panel, labelled with the catalog number, is cheaper than a production stop while somebody traces a five-dollar connector through a distributor's inventory.
Connector shells and thumb screws are part of the electrical specification on these cables, not accessories. A D-shell that is not fully seated produces a connection that passes a continuity test and fails under the load of a program upload. Any inspection procedure for a legacy programming link should include the mechanical condition of both ends, because that is where these cables fail.
Cables, cards and adapters for the same 1784 range are listed in the 1784 DH-485 category. This item itself can be checked against the shop listing at 1784-CP6.
Other catalog numbers and accessories for the same range are collected in the Allen-Bradley 1784 DH-485 and DH+ modules category.