logo
Home ProductsAB Network Switches 1783

Allen Bradley PLC 1783-BMS20CGL / 1783BMS20CGL

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1783-BMS20CGL / 1783BMS20CGL

China Allen Bradley PLC 1783-BMS20CGL / 1783BMS20CGL supplier
Allen Bradley PLC 1783-BMS20CGL / 1783BMS20CGL supplier Allen Bradley PLC 1783-BMS20CGL / 1783BMS20CGL supplier Allen Bradley PLC 1783-BMS20CGL / 1783BMS20CGL supplier Allen Bradley PLC 1783-BMS20CGL / 1783BMS20CGL supplier Allen Bradley PLC 1783-BMS20CGL / 1783BMS20CGL supplier

Large Image :  Allen Bradley PLC 1783-BMS20CGL / 1783BMS20CGL

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1783-BMS20CGL / 1783BMS20CGL

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $2129.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1783-BMS20CGL technical data PDF download 1783-BMS20CGL Rockwell Stratix 5700 20 Port Managed Switch, Lite Firmware

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: Stratix 5700 / 8000 / 8300 / 2000 · 1783

1783-BMS20CGL is a DIN rail managed switch designed to sit in the control cabinet on the same 24V dc bus as the controllers — 20 ports.

The L suffix is the Lite firmware build. That matters at replacement time, because Lite and Full switches are not interchangeable in a ring that depends on features only Full provides.

1783-BMS20CL Stratix 5700, 20 ports, 16 copper + 2 combo + 2 SFP IN STOCK
1783-BMS20CGP Stratix 5700, 20 ports, gigabit combo IN STOCK
1783-BMS20CGL Stratix 5700, 20 ports, gigabit combo, Lite firmware IN STOCK
1783-BMS20CGPK Stratix 5700, 20 ports, gigabit combo, kit IN STOCK
1783-BMS06TA Stratix 5700, 6 copper ports IN STOCK
1783-BMS06TL Stratix 5700, 6 copper ports, Lite firmware IN STOCK
1783-BMS06TGA Stratix 5700, 4 copper + 2 gigabit copper IN STOCK
1783-BMS06SA Stratix 5700, 4 copper + 2 SFP IN STOCK
1783-BMS06SL Stratix 5700, 4 copper + 2 SFP, Lite firmware IN STOCK
1783-BMS06SGA Stratix 5700, 4 copper + 2 gigabit SFP IN STOCK
1783-BMS06SGL Stratix 5700, 4 copper + 2 gigabit SFP, Lite firmware IN STOCK
1783-MS06T Stratix 8000, 6 port chassis IN STOCK
1783-MS10T Stratix 8000, 10 port chassis IN STOCK
1783-RMS06T Stratix 8300, 6 port layer 3 IN STOCK
1783-RMS10T Stratix 8300, 10 port layer 3 IN STOCK
1783-EMS04T Stratix 6000, 4 port managed IN STOCK
1783-MX08T Stratix 8000 copper 8 port expansion IN STOCK
1783-MX08F Stratix 8000 fibre 8 port expansion IN STOCK
1783-MCF Stratix 8000 CompactFlash spare card IN STOCK
1783-RMCF Stratix 8300 CompactFlash spare card IN STOCK
1783-ETAP EtherNet/IP tap, 3 copper ports IN STOCK
1783-ETAP2F EtherNet/IP tap, 1 copper + 2 fibre IN STOCK
1783-SFP100FX 100FX multimode SFP, 2 km IN STOCK
1783-SFP100LX 100LX singlemode SFP, 10 km IN STOCK
1783-SFP1GSX 1000SX multimode SFP, 550 m IN STOCK
1783-SFP1GLX 1000LX singlemode SFP, 10 km IN STOCK
1783-US8T Stratix 2000, 8 copper ports, unmanaged IN STOCK
1783-US03T01F Stratix 2000, 3 copper + 1 fibre, unmanaged IN STOCK

Product Specifications 1783-BMS20CGL (PDF)
 Catalog number
 1783-BMS20CGL
 Product family
 Stratix 5700 20 port managed switch
 Total ports
 20 ports
 Copper ports
 16 * 10/100 RJ45
 SFP ports
 2 * 10/100 SFP
 Combination ports
 2 * 10/100/1000 RJ45 / Mini-GBIC
 Power input
 12…48V dc, Class 2 / SELV, 0.5 A
 Power consumption
 30 W maximum, 21 W at 24V dc and 40 °C
 Weight
 2.04 kg
 Mounting
 DIN rail (top hat rail)
 Firmware type
 Lite
 Lifecycle status
 Discontinued September 01, 2024
 Replacement category
 Engineering Replacement
 Replacement product
 1783-CMS20DB
 Publication
 1783-UM011

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1783-UM011 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1783-BMS20CGL 1783-BMS20CGL

Ports

Copper: 16 * 10/100 RJ45. SFP: 2 * 10/100 SFP. Combination: 2 * 10/100/1000 RJ45 / Mini-GBIC.

A combination port accepts either an RJ45 module or a Mini-GBIC, so the copper count and the fibre count cannot both be taken at face value on a unit where both are populated.

Power and mounting

12…48V dc, Class 2 / SELV, 0.5 A; 30 W maximum, 21 W at 24V dc and 40 °C; DIN rail (top hat rail).

An alarm relay rated 1 A at 30V dc switches a panel lamp or a PLC input when the switch loses a supply or a monitored condition. That contact is often the only thing an operator sees when the network fails. A wide 12…48V dc range is deliberate: the switch runs from the same supply as the controllers.

Where it sits in the plant

The 20 port chassis aggregates a cell: sixteen copper devices, two combination ports and two SFP cages for the inter-cabinet fibre.

Managed switching inside a panel is about segmentation and diagnostics, not throughput. A cell/zone layout with IGMP snooping is what stops multicast I/O traffic from flooding every port in the cabinet.

Lifecycle

Discontinued September 01, 2024, replacement category Engineering Replacement, replacement product 1783-CMS20DB.

Existing units stay in service for years after a switch is retired. The practical questions are spare hardware and configuration backup — a replacement switch with no saved configuration is not a spare.

Buying used

Ask for the firmware revision, the configuration export and a photograph of the label. On a managed switch these three matter more than cosmetic condition.

A unit pulled from a working line with a documented configuration is worth more than an unconfigured identical unit, and should be priced that way.

FAQ — 1783-BMS20CGL

How many ports does 1783-BMS20CGL have?

20 ports

What power does 1783-BMS20CGL need?

12…48V dc, Class 2 / SELV, 0.5 A

Is 1783-BMS20CGL still available from Rockwell?

No. Discontinued September 01, 2024; replacement category Engineering Replacement.

What replaces 1783-BMS20CGL?

1783-CMS20DB

What is 1783-BMS20CGL used for?

Stratix 5700 20 port managed switch — a managed Ethernet switch for a control network.


Data sources. Port composition, weight, power consumption and firmware type come from the Rockwell product page data for this catalog number; the Stratix 5700 platform documentation is 1783-UM011. Any attribute a publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1783-BMS20CGL: 20 port managed switch with 2 GE SFP slots, Lite firmware

1783-BMS20CGL is a Stratix industrial Ethernet switch from the Allen-Bradley range, specified here against the Rockwell technical data rather than a distributor summary, so the port count, the supply range and the temperature ceiling are the figures an integrator can build a cabinet around.

SpecificationValue
Port configuration16 Fast Ethernet RJ45 ports plus 2 Gigabit SFP slots plus 2 Fast Ethernet ports
FirmwareLite firmware, Gigabit uplink and a full row of copper drops
Alarm relay1 A at 30V DC or 0.5 A at 48V DC
Power input12 to 48V DC, Class 2 or SELV, 0.5 to 3.0 A maximum depending on model
Power consumption9.5 to 21 W at 24V DC and 40 degrees C, 14 to 30 W maximum across the range
Ethernet rateFast Ethernet 10/100 Mbps on RJ45 ports, Gigabit on the GE ports and SFP slots
CablingRJ45 to IEC 60603-7, Category 5e minimum to TIA 568-B.1 or Category 5 to ISO/IEC 24702
Wire size, power0.5 to 0.8 mm2 (20 to 18 AWG) copper rated 75 degrees C or higher, 1.2 mm insulation maximum
Operating temperature-40 to 60 degrees C, surrounding air maximum 60 degrees C
Storage temperature-40 to 85 degrees C
Humidity5 to 95 percent noncondensing
Shock and vibration30 g operating, 55 g nonoperating, 2 g at 10 to 500 Hz
EmissionsCISPR 11 Class A, ESD 8 kV contact and 15 kV air
Enclosure ratingIP30, open style
Source1783-TD002D-EN-P, May 2023

Read the suffix rather than the base number when specifying this unit. The same six port body is sold as T, S or SG and as L or A, and the difference between an L and an A part is whether the firmware carries the ring and time synchronisation features that a coordinated cell depends on. A Lite unit is a real product, not a crippled one, and it is the right choice where the cell only needs a transparent switch with diagnostics.

DIN rail mounting and panel mounting are both supported, and in this range the 20 port units are the ones usually chosen as the aggregation point of a line: sixteen copper drops cover a row of drives and I/O heads, two Gigabit SFP slots carry the uplink to the plant backbone, and the two remaining Fast Ethernet ports serve the local HMI or a diagnostics laptop.

Where a value in this table is a range rather than a single figure, it is a range because the Rockwell table publishes it that way across the model group; the individual unit is then fixed by its catalog suffix. Anything an engineer needs beyond this, including the certification file and the full EMC test list, is in the technical data publication named at the bottom of the table.

The distance an SFP reaches is a property of the optic and the fiber, not of the switch. Multimode runs to a few hundred meters, singlemode runs to kilometers, and the budget has to cover connectors and splices, so the link loss calculation belongs in the same document as the port list.

An unmanaged switch has no address and no configuration, so it either forwards frames or it does not. That is a feature in a machine cell where nobody wants a config file to restore after a controller swap, and it is a liability in a line where someone needs to know which port dropped a packet.

On 1783-BMS20CGL conformal coating is a suffix rather than a separate product, and it matters in washdown or sulfur bearing atmospheres. Where a cabinet sits in a food plant or near a rubber process, the coated variant is the one to quote, because condensation on an uncoated board is a failure that shows up months later.

Commissioning a switch takes an afternoon the first time and twenty minutes afterwards: address it, set the ring or the redundant path, confirm the port counters stay clean under load, and record the firmware revision on the as-built drawing. The failures that survive to production are almost always a duplicate address or a loop nobody documented.

On 1783-BMS20CGL the 24V DC input is Class 2 or SELV, which is what allows a cabinet to feed them from the same distribution as the PLC without a separate transformer. Where a site still runs 24V AC, that option exists on the unmanaged range and disappears on the managed ones, and the difference is worth checking before a retrofit order is placed.

Precision time is a separate question from data. IEEE 1588 CIP Sync is what lets a controller timestamp an input at the switch edge rather than at the scanner, and only the Full firmware variants carry it. If an application needs coordinated motion or sequence of events, the Lite part on the shelf will not do the job.

Temperature is quoted at the surrounding air rather than at the board, and the 60 degrees C ceiling on the managed units is lower than the 70 degrees C that the FLEX Ex and most I/O families allow. A cabinet that was designed around an I/O module rating will need a thermal review before a switch is added at the top of the rail.

A switch that has been in a cabinet for eight years, 1783-BMS20CGL among them, is usually still electrically sound and functionally obsolete. The practical question at replacement time is whether the firmware can still be managed by the current tool, and a unit that cannot be reached by the engineering software is a unit that will be replaced on failure rather than on schedule.

A managed switch adds the diagnostics that make a network debuggable: port level counters, spanning tree, and in the Stratix range a Device Level Ring that survives a single cable break. The catalog suffix tells you whether that firmware is present, and a Lite unit is not upgradeable into a Full one by flashing it. For 1783-BMS20CGL the suffix is the only reliable statement of which firmware set ships.

Every one of these units, 1783-BMS20CGL included, is open style, which means it belongs in an enclosure with a pollution degree 2 environment. The IP30 rating protects against fingers and tools, not against water, and a switch mounted on an open panel in a wet area is a warranty claim waiting to happen.

Cybersecurity hardening starts at the switch, not at the firewall. Disabling unused ports, changing the default credentials, and keeping the management interface off the plant backbone are the three steps that close most findings in an industrial network assessment, and none of them require a licence.

Ethernet ports are rated for Category 5e cable at minimum, and the connector is the IEC 60603-7 RJ45 that every industrial patch cord already uses. Where a cabinet is wired with older Category 5 cable, the link will usually train at 100 Mbps but the error counters will climb, which is why the cable class is printed next to the port table.

For 1783-BMS20CGL the NAT variants exist for the machine builder who must hand over a cell with a fixed internal address scheme. A configurable NAT router lets the same internal IP plan be reused on every machine while the plant side sees a different address, which removes an entire class of commissioning arguments.

Spare parts strategy on a switch is driven by firmware, not by hardware. A Lite spare cannot replace a Full unit in a ring that depends on CIP Sync, so the stocking list should carry the suffix rather than the base number, and the label on the failed unit is the authority.

Confirm the ring or uplink topology on the drawing before ordering, check the 60 degrees C surrounding air limit against the cabinet thermal calculation, and record the firmware suffix on the spare parts list.

Other catalog numbers and accessories for the same range are collected in the Allen-Bradley 1783 network switches category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)