Product Details:
Payment & Shipping Terms:
|
1783-MS06T is a modular managed switch: fixed ports on the chassis, further ports on 8-port expansion modules — 6 ports.
The 8000 is the modular line: 117.5 mm depth, expansion in 8-port modules, and a chassis that can stay in service while ports are added around it.
| 1783-BMS20CL | Stratix 5700, 20 ports, 16 copper + 2 combo + 2 SFP | IN STOCK |
| 1783-BMS20CGP | Stratix 5700, 20 ports, gigabit combo | IN STOCK |
| 1783-BMS20CGL | Stratix 5700, 20 ports, gigabit combo, Lite firmware | IN STOCK |
| 1783-BMS20CGPK | Stratix 5700, 20 ports, gigabit combo, kit | IN STOCK |
| 1783-BMS06TA | Stratix 5700, 6 copper ports | IN STOCK |
| 1783-BMS06TL | Stratix 5700, 6 copper ports, Lite firmware | IN STOCK |
| 1783-BMS06TGA | Stratix 5700, 4 copper + 2 gigabit copper | IN STOCK |
| 1783-BMS06SA | Stratix 5700, 4 copper + 2 SFP | IN STOCK |
| 1783-BMS06SL | Stratix 5700, 4 copper + 2 SFP, Lite firmware | IN STOCK |
| 1783-BMS06SGA | Stratix 5700, 4 copper + 2 gigabit SFP | IN STOCK |
| 1783-BMS06SGL | Stratix 5700, 4 copper + 2 gigabit SFP, Lite firmware | IN STOCK |
| 1783-MS06T | Stratix 8000, 6 port chassis | IN STOCK |
| 1783-MS10T | Stratix 8000, 10 port chassis | IN STOCK |
| 1783-RMS06T | Stratix 8300, 6 port layer 3 | IN STOCK |
| 1783-RMS10T | Stratix 8300, 10 port layer 3 | IN STOCK |
| 1783-EMS04T | Stratix 6000, 4 port managed | IN STOCK |
| 1783-MX08T | Stratix 8000 copper 8 port expansion | IN STOCK |
| 1783-MX08F | Stratix 8000 fibre 8 port expansion | IN STOCK |
| 1783-MCF | Stratix 8000 CompactFlash spare card | IN STOCK |
| 1783-RMCF | Stratix 8300 CompactFlash spare card | IN STOCK |
| 1783-ETAP | EtherNet/IP tap, 3 copper ports | IN STOCK |
| 1783-ETAP2F | EtherNet/IP tap, 1 copper + 2 fibre | IN STOCK |
| 1783-SFP100FX | 100FX multimode SFP, 2 km | IN STOCK |
| 1783-SFP100LX | 100LX singlemode SFP, 10 km | IN STOCK |
| 1783-SFP1GSX | 1000SX multimode SFP, 550 m | IN STOCK |
| 1783-SFP1GLX | 1000LX singlemode SFP, 10 km | IN STOCK |
| 1783-US8T | Stratix 2000, 8 copper ports, unmanaged | IN STOCK |
| 1783-US03T01F | Stratix 2000, 3 copper + 1 fibre, unmanaged | IN STOCK |
Catalog number |
1783-MS06T |
Product family |
Stratix 8000 6 port managed switch |
Total ports |
6 ports |
Copper ports |
6 * 10/100 RJ45 |
SFP ports |
None |
Combination ports |
None |
Power input |
18…60V dc, Class 2 / SELV, 2 A switch input |
Power consumption |
Not published |
Weight |
Not published for this catalog number |
Mounting |
Panel mount |
Firmware type |
Not published for this catalog number |
Lifecycle status |
Discontinued November 30, 2020 |
Replacement category |
Functional Replacement |
Replacement product |
Not named on the product page |
Publication |
1783-UM011 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1783-UM011 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Copper: 6 * 10/100 RJ45. SFP: None. Combination: None.
A combination port accepts either an RJ45 module or a Mini-GBIC, so the copper count and the fibre count cannot both be taken at face value on a unit where both are populated.
18…60V dc, Class 2 / SELV, 2 A switch input; Not published; Panel mount.
An alarm relay rated 1 A at 30V dc switches a panel lamp or a PLC input when the switch loses a supply or a monitored condition. That contact is often the only thing an operator sees when the network fails.
A six port chassis with the option to add 8-port blocks later is how a panel grows without a second switch to manage.
Managed switching inside a panel is about segmentation and diagnostics, not throughput. A cell/zone layout with IGMP snooping is what stops multicast I/O traffic from flooding every port in the cabinet.
Discontinued November 30, 2020, replacement category Functional Replacement; the product page names no specific replacement product for this catalog number.
Existing units stay in service for years after a switch is retired. The practical questions are spare hardware and configuration backup — a replacement switch with no saved configuration is not a spare.
Ask for the firmware revision, the configuration export and a photograph of the label. On a managed switch these three matter more than cosmetic condition.
A unit pulled from a working line with a documented configuration is worth more than an unconfigured identical unit, and should be priced that way.
How many ports does 1783-MS06T have?
6 ports
What power does 1783-MS06T need?
18…60V dc, Class 2 / SELV, 2 A switch input
Is 1783-MS06T still available from Rockwell?
No. Discontinued November 30, 2020; replacement category Functional Replacement.
What replaces 1783-MS06T?
The product page lists Engineering Replacement without naming a specific replacement product.
What is 1783-MS06T used for?
Stratix 8000 6 port managed switch — a managed Ethernet switch for a control network.
1783-MS06T is part of the Stratix industrial Ethernet range from Allen-Bradley, and this page carries the figures from the Rockwell technical data so that a cabinet can be sized and a spare ordered without going back to a distributor datasheet.
| Specification | Value |
|---|---|
| Description | Stratix 8000 Layer 2 managed switch, 6 ports |
| Ports | 6 RJ45 ports |
| Layer | Layer 2 switching |
| Power input | 18 to 60V DC, 2 A maximum, Class 2 or SELV; inrush 2.0 A |
| Alarm relay | 1 A maximum at 30V DC, Class 2 or SELV |
| Power consumption | 15.1 maximum, expansion module power not included |
| Power dissipation | 15.1 |
| Isolation | 75V continuous basic insulation, power to ground, to network channels and to alarm; no isolation between Ethernet ports; type tested 1000V AC for 60 s |
| Wire size, power and alarm | 0.5 to 0.8 mm2 (20 to 18 AWG) copper rated 90 degrees C or higher, 1.2 mm insulation maximum |
| Wire size, ground | 3.3 to 5.3 mm2 (12 to 10 AWG) copper rated 75 degrees C or higher |
| Terminal torque | 0.23 N m (2.0 in lb) on power and alarm terminals |
| Operating temperature | -40 to 60 degrees C, surrounding air maximum 60 degrees C |
| Storage temperature | -40 to 85 degrees C, 5 to 95 percent noncondensing |
| Clearances | 105 mm top and bottom, 90 mm left and right, 65 mm front for unrestricted airflow |
| Expansion | Six expansion modules available: 1783-MX08T, -MX08F, -MX04S, -MX08S, -MX04E, -MX04T04E |
| SFP support | SFP modules only in switches with combo ports or SFP slots |
| Certification | UL file E65584 and E194810, Class I Division 2 and Zone 2, Ex nA nC IIC T4 Gc X |
| Memory card | 1783-MCF |
| Source | 1783-TD002D-EN-P, May 2023 |
The difference between the 8000 and the 8300 is the layer, not the port count: the 8000 switches at Layer 2 and the 8300 routes at Layer 3, and that decides whether a cell can be segmented into subnets at the switch or must go back to a router. Both bodies exist in a 6 port and a 10 port version with the same 15.1 or 15.7 W consumption, so the choice is a network design choice rather than a power budget choice.
Expansion is the reason these two models still matter in a brownfield cabinet: a base switch takes one of six expansion modules, from eight additional copper ports to eight fiber ports or four to eight SFP slots. The base unit consumption figures exclude the expansion module, so the cabinet budget has to add the module figure separately, and the clearances of 105 mm above and below are larger than most other DIN rail devices.
Where the Rockwell table prints a maximum rather than a typical value, this page keeps the maximum, because a power budget built on typical numbers fails on the coldest morning of the year rather than on the day it was designed.
Every one of these units, 1783-MS06T included, is open style, which means it belongs in an enclosure with a pollution degree 2 environment. The IP30 rating protects against fingers and tools, not against water, and a switch mounted on an open panel in a wet area is a warranty claim waiting to happen.
Cybersecurity hardening starts at the switch, not at the firewall. Disabling unused ports, changing the default credentials, and keeping the management interface off the plant backbone are the three steps that close most findings in an industrial network assessment, and none of them require a licence.
Ethernet ports are rated for Category 5e cable at minimum, and the connector is the IEC 60603-7 RJ45 that every industrial patch cord already uses. Where a cabinet is wired with older Category 5 cable, the link will usually train at 100 Mbps but the error counters will climb, which is why the cable class is printed next to the port table.
For 1783-MS06T the NAT variants exist for the machine builder who must hand over a cell with a fixed internal address scheme. A configurable NAT router lets the same internal IP plan be reused on every machine while the plant side sees a different address, which removes an entire class of commissioning arguments.
Spare parts strategy on a switch is driven by firmware, not by hardware. A Lite spare cannot replace a Full unit in a ring that depends on CIP Sync, so the stocking list should carry the suffix rather than the base number, and the label on the failed unit is the authority.
In a plant network the switch is usually the part that gets blamed last and fails first, because it sits between a drive that trips and a controller that logs nothing. Keeping the port count, the supply range and the temperature rating on the page means a maintenance engineer can replace a unit without opening a drawing set.
Device Level Ring is the reason many of these switches exist in a machine line. A ring built from two ports per device survives one open cable without dropping the cell, and the recovery time is a property of the ring rather than of any single switch, so a mixed vendor ring has to be checked as a whole.
The emission class is CISPR 11 Class A, which is an industrial environment statement. Mounting one of these in a light industrial or residential panel can require additional filtering, and that is a compliance question rather than a performance one, so it belongs in the quotation stage.
The distance an SFP reaches is a property of the optic and the fiber, not of the switch. Multimode runs to a few hundred meters, singlemode runs to kilometers, and the budget has to cover connectors and splices, so the link loss calculation belongs in the same document as the port list.
An unmanaged switch has no address and no configuration, so it either forwards frames or it does not. That is a feature in a machine cell where nobody wants a config file to restore after a controller swap, and it is a liability in a line where someone needs to know which port dropped a packet.
On 1783-MS06T conformal coating is a suffix rather than a separate product, and it matters in washdown or sulfur bearing atmospheres. Where a cabinet sits in a food plant or near a rubber process, the coated variant is the one to quote, because condensation on an uncoated board is a failure that shows up months later.
Commissioning a switch takes an afternoon the first time and twenty minutes afterwards: address it, set the ring or the redundant path, confirm the port counters stay clean under load, and record the firmware revision on the as-built drawing. The failures that survive to production are almost always a duplicate address or a loop nobody documented.
On 1783-MS06T the 24V DC input is Class 2 or SELV, which is what allows a cabinet to feed them from the same distribution as the PLC without a separate transformer. Where a site still runs 24V AC, that option exists on the unmanaged range and disappears on the managed ones, and the difference is worth checking before a retrofit order is placed.
Precision time is a separate question from data. IEEE 1588 CIP Sync is what lets a controller timestamp an input at the switch edge rather than at the scanner, and only the Full firmware variants carry it. If an application needs coordinated motion or sequence of events, the Lite part on the shelf will not do the job.
Add the expansion module consumption to the base figure before the power supply is sized, check the clearances against the rail layout, and confirm the memory card part number against the model before a spare is stocked.
This part sits in the Allen-Bradley 1783 network switches category, with the other models and spare parts listed alongside it.