Product Details:
Payment & Shipping Terms:
|
1783-MCF is the CompactFlash spare card for the Stratix 8000 managed switches — the removable media that carries firmware and configuration.
It is the cheapest part in the switch and the one that decides whether a replacement chassis comes up in minutes or in an afternoon.
| 1783-BMS20CL | Stratix 5700, 20 ports, 16 copper + 2 combo + 2 SFP | IN STOCK |
| 1783-BMS20CGP | Stratix 5700, 20 ports, gigabit combo | IN STOCK |
| 1783-BMS20CGL | Stratix 5700, 20 ports, gigabit combo, Lite firmware | IN STOCK |
| 1783-BMS20CGPK | Stratix 5700, 20 ports, gigabit combo, kit | IN STOCK |
| 1783-BMS06TA | Stratix 5700, 6 copper ports | IN STOCK |
| 1783-BMS06TL | Stratix 5700, 6 copper ports, Lite firmware | IN STOCK |
| 1783-BMS06TGA | Stratix 5700, 4 copper + 2 gigabit copper | IN STOCK |
| 1783-BMS06SA | Stratix 5700, 4 copper + 2 SFP | IN STOCK |
| 1783-BMS06SL | Stratix 5700, 4 copper + 2 SFP, Lite firmware | IN STOCK |
| 1783-BMS06SGA | Stratix 5700, 4 copper + 2 gigabit SFP | IN STOCK |
| 1783-BMS06SGL | Stratix 5700, 4 copper + 2 gigabit SFP, Lite firmware | IN STOCK |
| 1783-MS06T | Stratix 8000, 6 port chassis | IN STOCK |
| 1783-MS10T | Stratix 8000, 10 port chassis | IN STOCK |
| 1783-RMS06T | Stratix 8300, 6 port layer 3 | IN STOCK |
| 1783-RMS10T | Stratix 8300, 10 port layer 3 | IN STOCK |
| 1783-EMS04T | Stratix 6000, 4 port managed | IN STOCK |
| 1783-MX08T | Stratix 8000 copper 8 port expansion | IN STOCK |
| 1783-MX08F | Stratix 8000 fibre 8 port expansion | IN STOCK |
| 1783-MCF | Stratix 8000 CompactFlash spare card | IN STOCK |
| 1783-RMCF | Stratix 8300 CompactFlash spare card | IN STOCK |
| 1783-ETAP | EtherNet/IP tap, 3 copper ports | IN STOCK |
| 1783-ETAP2F | EtherNet/IP tap, 1 copper + 2 fibre | IN STOCK |
| 1783-SFP100FX | 100FX multimode SFP, 2 km | IN STOCK |
| 1783-SFP100LX | 100LX singlemode SFP, 10 km | IN STOCK |
| 1783-SFP1GSX | 1000SX multimode SFP, 550 m | IN STOCK |
| 1783-SFP1GLX | 1000LX singlemode SFP, 10 km | IN STOCK |
| 1783-US8T | Stratix 2000, 8 copper ports, unmanaged | IN STOCK |
| 1783-US03T01F | Stratix 2000, 3 copper + 1 fibre, unmanaged | IN STOCK |
Catalog number |
1783-MCF |
Description |
Stratix 8000 CompactFlash spare card |
Product type |
CompactFlash card |
For use with |
Stratix 8000 Ethernet managed switches |
Lifecycle status |
Discontinued November 30, 2020 |
Replacement category |
Functional Replacement |
UPC |
612598347704 |
Publication |
1783-UM011 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1783-UM011 (module specifications) and Rockwell literature library (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
A CompactFlash card used for firmware and configuration storage on the Stratix 8000 managed switches.
Rockwell publishes the product type and the switch family it serves; it publishes no capacity figure on the product page, so none is quoted here.
A spare switch with no configuration is a chassis, not a replacement. The card is how the configuration travels with the spare.
Refresh the card after any change to VLANs, ring settings or IP addressing — the same discipline as a program archive on a PLC.
CompactFlash media dislikes heat and careless insertion. Keep the card in its case and do not reformat it outside the switch.
Label the card with the panel it belongs to. The wrong configuration in the right switch is worse than no configuration at all.
Discontinued November 30, 2020 with the Stratix 8000 line, replacement category Functional Replacement.
Cards remain available on the secondary market, but a card with no known-good image is of little use — the value is in the image, not the media.
Stratix 8000 chassis: 1783-MS06T, 1783-MS10T; expansion modules 1783-MX08T and 1783-MX08F.
Stratix 8300 chassis: 1783-RMS06T, 1783-RMS10T, which take the 1783-RMCF card.
What is 1783-MCF?
The CompactFlash spare card for Stratix 8000 managed switches.
Does 1783-MCF store the configuration?
Yes — it is the firmware and configuration media for the switch.
Is 1783-MCF still available from Rockwell?
No. Discontinued November 30, 2020.
What capacity is 1783-MCF?
Rockwell publishes no capacity figure for this catalog number.
Why keep a spare card?
So a replacement chassis can be restored to the known-good configuration.
1783-MCF is part of the Stratix industrial Ethernet range from Allen-Bradley, and this page carries the figures from the Rockwell technical data so that a cabinet can be sized and a spare ordered without going back to a distributor datasheet.
| Specification | Value |
|---|---|
| Function | memory card for the Stratix 8000 |
| Host switch | Stratix 8000 base switches |
| Publication listing | Named as the memory card for the Stratix 8000 in the switch technical data |
| Replacement card | 1784-SD1 is the replacement memory card listed for the Stratix 5700 and 5800 ranges, not for this family |
| Card capacity | Not published in the technical data table; read the capacity from the label on the card |
| Fitting | Fitted in the switch memory card slot, read at boot |
| Purpose | Carries the stored image and configuration so a replacement switch comes up without a laptop |
| Related | 1783-MS06T, -MS10T for the 8000; -RMS06T, -RMS10T for the 8300 |
| Source | 1783-TD002D-EN-P, May 2023 |
This is a small part that decides how a failure is handled rather than how a network performs. With the card in place, a failed switch is swapped and boots from the card; without it, the replacement needs an engineer, a laptop and the right firmware revision before the line restarts. The technical data lists the card by catalog number only and does not publish a capacity figure, so the card label is the authority for what is actually fitted.
The two numbers are not interchangeable across the families. 1783-MCF is the card listed for the Stratix 8000 and 1783-RMCF for the Stratix 8300, and the 1784-SD1 that appears in the 5700 and 5800 tables is a different part. Ordering by capacity rather than by catalog number is how a card ends up in the wrong switch.
Where the Rockwell table prints a maximum rather than a typical value, this page keeps the maximum, because a power budget built on typical numbers fails on the coldest morning of the year rather than on the day it was designed.
Cybersecurity hardening starts at the switch, not at the firewall. Disabling unused ports, changing the default credentials, and keeping the management interface off the plant backbone are the three steps that close most findings in an industrial network assessment, and none of them require a licence.
Ethernet ports are rated for Category 5e cable at minimum, and the connector is the IEC 60603-7 RJ45 that every industrial patch cord already uses. Where a cabinet is wired with older Category 5 cable, the link will usually train at 100 Mbps but the error counters will climb, which is why the cable class is printed next to the port table.
For 1783-MCF the NAT variants exist for the machine builder who must hand over a cell with a fixed internal address scheme. A configurable NAT router lets the same internal IP plan be reused on every machine while the plant side sees a different address, which removes an entire class of commissioning arguments.
Spare parts strategy on a switch is driven by firmware, not by hardware. A Lite spare cannot replace a Full unit in a ring that depends on CIP Sync, so the stocking list should carry the suffix rather than the base number, and the label on the failed unit is the authority.
In a plant network the switch is usually the part that gets blamed last and fails first, because it sits between a drive that trips and a controller that logs nothing. Keeping the port count, the supply range and the temperature rating on the page means a maintenance engineer can replace a unit without opening a drawing set.
Device Level Ring is the reason many of these switches exist in a machine line. A ring built from two ports per device survives one open cable without dropping the cell, and the recovery time is a property of the ring rather than of any single switch, so a mixed vendor ring has to be checked as a whole.
The emission class is CISPR 11 Class A, which is an industrial environment statement. Mounting one of these in a light industrial or residential panel can require additional filtering, and that is a compliance question rather than a performance one, so it belongs in the quotation stage.
The distance an SFP reaches is a property of the optic and the fiber, not of the switch. Multimode runs to a few hundred meters, singlemode runs to kilometers, and the budget has to cover connectors and splices, so the link loss calculation belongs in the same document as the port list.
An unmanaged switch has no address and no configuration, so it either forwards frames or it does not. That is a feature in a machine cell where nobody wants a config file to restore after a controller swap, and it is a liability in a line where someone needs to know which port dropped a packet.
On 1783-MCF conformal coating is a suffix rather than a separate product, and it matters in washdown or sulfur bearing atmospheres. Where a cabinet sits in a food plant or near a rubber process, the coated variant is the one to quote, because condensation on an uncoated board is a failure that shows up months later.
Commissioning a switch takes an afternoon the first time and twenty minutes afterwards: address it, set the ring or the redundant path, confirm the port counters stay clean under load, and record the firmware revision on the as-built drawing. The failures that survive to production are almost always a duplicate address or a loop nobody documented.
On 1783-MCF the 24V DC input is Class 2 or SELV, which is what allows a cabinet to feed them from the same distribution as the PLC without a separate transformer. Where a site still runs 24V AC, that option exists on the unmanaged range and disappears on the managed ones, and the difference is worth checking before a retrofit order is placed.
Precision time is a separate question from data. IEEE 1588 CIP Sync is what lets a controller timestamp an input at the switch edge rather than at the scanner, and only the Full firmware variants carry it. If an application needs coordinated motion or sequence of events, the Lite part on the shelf will not do the job.
Temperature is quoted at the surrounding air rather than at the board, and the 60 degrees C ceiling on the managed units is lower than the 70 degrees C that the FLEX Ex and most I/O families allow. A cabinet that was designed around an I/O module rating will need a thermal review before a switch is added at the top of the rail.
Write the card catalog number into the spare parts list beside the switch, confirm the capacity on the label rather than in a quotation, and keep one card per critical switch rather than one in the maintenance cupboard.
Browse the Allen-Bradley 1783 network switches category for the other models, options and spare parts that share this range.