logo
Home ProductsAB PLC-5 Systems

Allen Bradley PLC 1771-ILK / 1771ILK

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1771-ILK / 1771ILK

China Allen Bradley PLC 1771-ILK / 1771ILK supplier
Allen Bradley PLC 1771-ILK / 1771ILK supplier Allen Bradley PLC 1771-ILK / 1771ILK supplier Allen Bradley PLC 1771-ILK / 1771ILK supplier Allen Bradley PLC 1771-ILK / 1771ILK supplier Allen Bradley PLC 1771-ILK / 1771ILK supplier

Large Image :  Allen Bradley PLC 1771-ILK / 1771ILK

Product Details:

Place of Origin: Made in USA
Brand Name: PLC Module
Certification: All goods we supply with 1 year warranty!
Model Number: Allen Bradley PLC 1771-ILK / 1771ILK

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $2815.00 (USD/PCS)
Packaging Details: 100% New packaging
Delivery Time: IN STOCK; 2-4 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description

1771-ILK

This page covers catalog number 1771-ILK, the catalog number this shop lists as 1771-ILK, set against the published 1771-IL isolated analog input module data. Where a suffix on this listing is not defined by the manufacturer, the page says so and prints the documented module data; no specification has been invented for the suffix.

Published data for the module behind this catalog number

SpecificationValue
Catalog number, module1771-IL, Series C
Number of inputs8, fully isolated differential
Module location1771 I/O rack, one slot
Voltage ranges+1 to +5V DC, 0 to 5V DC, -5 to +5V DC, -10 to +10V DC
Current ranges+4 to +20 mA, 0 to +20 mA, -20 to +20 mA
Range selectionSeven ranges, two bits per channel in the block transfer write; default 1 to 5V DC and 4 to 20 mA
Resolution16-bit binary over the full range
Accuracy, voltageTypical 0.01%, maximum 0.05% of full scale at 25 °C
Accuracy, currentTypical 0.06%, maximum 0.1% of full scale at 25 °C, including 0.05% for the internal current resistor
Linearity and repeatability±1 LSB each
IsolationChannel to channel and channel to ground, 1000V; meets or exceeds UL 508 and CSA C22.2 No. 142
Overvoltage protectionVoltage mode 140V AC rms continuous; current mode 8V DC continuous
Input impedanceAbove 10 MΩ voltage ranges; 250 Ω current ranges
Common mode rejectionAbove 120 dB at 60 Hz with 1 kΩ source imbalance
Common mode impedanceAbove 50 MΩ shunted by less than 5 nF
Normal mode rejectionAbove 60 dB at 60 Hz
Open circuit detectionVoltage mode reads upscale; current mode reads zero; detected within 10 s
CalibrationAuto-calibration of offset and gain, plus zero and gain adjustment per channel; verify every six months
Data to processorUnscaled 0000 to 4095 for unipolar ranges, -4095 to 4095 for bipolar; engineering units ±9999 BCD or ±32767 binary
Scan rate50 ms for 8 channels, without scaling or digital filtering
Backplane current1.1 A at +5V
Power dissipation5.5 W maximum, 18.8 BTU/hr
Conductors14 gauge (2 mm2) stranded maximum, 3/64 in. insulation maximum
Voltage or current selectionA jumper on the functional analog block must be set before the module is inserted; voltage and current modes can be mixed
Wiring arm1771-WF, per the series B user manual, publication 1771-6.5.91
Series differencesA: 12-bit, 1.3 A, 6.5 W, 22.2 BTU/hr. B: 16-bit, 1.0 A, 5.0 W, 17.1 BTU/hr. C: 16-bit, 1.1 A, 5.5 W, 18.8 BTU/hr and common mode rejection above 150 dB
LifecycleDiscontinued 31 May 2017, Engineering Replacement category
Publication1771-IN051, and user manual 1771-6.5.91

What the published figures mean in a panel

Wiring arm and jumper are the two physical facts a spare module arrives without. The arm stays with the chassis, and the voltage or current jumper is set on the module's own analog block, so a replacement fitted with the wrong jumper mode reads a plausible number in the wrong scale on every channel at once.

Fifty milliseconds for eight channels is published as the internal scan without scaling or filtering, and block transfer cannot read it faster. A control loop that needs a faster analog update needs a different card, not a faster program, and the published figure is the ceiling the programmer inherits.

The jumper that selects voltage or current sits on the functional analog block and has to be set before the module goes into the chassis. That is an unusual instruction, and it exists because the setting is physical: a channel configured for current with the jumper on voltage reads a number in the wrong scale and looks healthy while it does it.

Fully isolated differential inputs are published as channel to channel and channel to ground at one thousand volts. That is what allows eight transmitters with different ground references to share one card without a common mode problem, and it is the reason this module costs more than the non-isolated analog cards in the same chassis.

Sixteen bit resolution is published over the full range, and the accuracy figures are what sit underneath it. A typical voltage error of one hundredth of a percent of full scale is fine resolution with real accuracy behind it; the current figure of one tenth of a percent including the internal resistor is the honest number for a 4 to 20 mA loop.

Open circuit behaviour is published by mode: voltage inputs read upscale, current inputs read zero, and detection takes up to ten seconds. Two different failure directions in one module is a design decision worth recording, because a program that checks for underrange will never see a broken voltage input.

Series A used mechanical adjustments and twelve bit resolution; series B and C are sixteen bit with auto-calibration. The published backplane currents also differ, one point three amps for A against one point one for C, and the thermal figures move with them, so a chassis planned for one series is not automatically adequate for another.

The aluminum block on the module is the analog front end, and the published instruction to mix voltage and current modes across channels follows from it. Mixing is allowed, but the jumper is shared per group of channels rather than per channel in some builds, so the published table and the physical board have to be read together rather than assumed.

Calibration is automatic for offset and gain, with per channel zero and gain adjustment available from the programming terminal, and the manual still asks for a six month verification. Auto-calibration tracks the electronics; the six month check catches the terminations and the field loop, which the electronics cannot see.

The series C common mode rejection figure of one hundred and fifty decibels is higher than the one hundred and twenty published for series A and B, which is a published difference rather than a marketing one. In a cabinet beside a drive, that thirty decibel margin is the difference between a stable reading and a wandering one.

An isolated analog input is specified by its isolation, its accuracy and its common mode behaviour, in that order. A page that leads with resolution tells an engineer nothing about whether the card can live in the panel he has, and this module's own published rows make the priority clear.

The module is discontinued, and the replacement path is a platform change rather than a card swap. The published data still matters because the installed base runs on it, and the rows that decide a replacement are the isolation, the range set, the accuracy by mode and the backplane current.

One point one amps at five volts is the highest backplane draw in this chassis family's analog cards, and it is published as such. A chassis that carries two of these and a processor is planning against a supply budget rather than a slot count, and the budget is the row to check first.

The other 1771 modules and PLC-5 chassis parts are collected in the PLC-5 category. This catalog number can be checked against the shop listing at 1771-ILK.