logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-DHRIO / 1756DHRIO

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-DHRIO / 1756DHRIO

China Allen Bradley PLC 1756-DHRIO / 1756DHRIO supplier
Allen Bradley PLC 1756-DHRIO / 1756DHRIO supplier Allen Bradley PLC 1756-DHRIO / 1756DHRIO supplier Allen Bradley PLC 1756-DHRIO / 1756DHRIO supplier Allen Bradley PLC 1756-DHRIO / 1756DHRIO supplier Allen Bradley PLC 1756-DHRIO / 1756DHRIO supplier

Large Image :  Allen Bradley PLC 1756-DHRIO / 1756DHRIO

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-DHRIO / 1756DHRIO

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1088.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-DHRIO technical data PDF download ControlLogix 1756-DHRIO / 1756DHRIO DH+ and Remote I/O Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-DHRIO (also written 1756DHRIO) is the Data Highway Plus and remote I/O bridge for the ControlLogix 1756 platform: two ports on the front, each selectable independently as DH+ or remote I/O, chassis mounted and one slot wide. It is the module that lets a ControlLogix controller own an installed base of legacy SLC, PLC-5 and 1771 remote racks instead of replacing that wiring.

DH+ runs at 57.6, 115.2 or 230.4 kbps. In remote I/O mode the module is a scanner only, with 32 logical rack connections and 16 block transfer connections per channel; the module supports 32 connections in total (1756-TD003 Table 13). Current draw is 850 mA at 5.1 V DC plus 1.7 mA at 24 V DC, dissipating 4.5 W and 15.4 BTU/hr. Isolation is 30 V continuous basic insulation from DHRIO A and B to the backplane and from the A port to the programming port, with no isolation between port A and the programming port, type tested at 877 V DC for 60 s.

1756-DHRIO DH+ or remote I/O bridge, two selectable ports, 32 connections IN STOCK
1756-RIO Remote I/O module, scanner or adapter, 32 physical racks IN STOCK
1756-DH485 DH-485 network communication module IN STOCK
1756-SYNCH SynchLink fibre module, 5 Mbps, 50 us frame, 2 ports IN STOCK

 Application
 DH+ / Remote I/O
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-DHRIO
 Communication
 DH+ / Remote I/O
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 2 ports, each DH+ or remote I/O
 Mounting
 Chassis
 Number Of Channels
 2
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix system user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-DHRIO product photograph product photograph 1756-DHRIO module product photograph 1756-DHRIO module, second view product photograph

Where the module sits in a typical system

The module is the retrofit slot. An existing PLC-5 or SLC installation keeps its 1771 racks, its DH+ peer links and its block transfers, and the ControlLogix controller reads and writes them through this one card — no rewiring of the legacy drops.

The limits are the planning figures: 32 logical rack connections and 16 block transfer connections per channel, 32 connections in total, at 57.6/115.2/230.4 kbps. A segment that already saturates those numbers is not extended by adding a second DHRIO to the same chassis; it is re-scoped.

Commissioning in five steps

  1. Set the link parameters before the module joins the network: DH+ node address and baud rate, remote I/O rack assignment and starting quarter, or the SynchLink node role. A legacy link carries no traffic until these match the existing segment.
  2. Terminate and shield the trunk to the published rules — 1786-RG6 coax for remote I/O, Belden 9463 or equivalent for DH+, 200/230 µm HCS fibre with Versalink V-System connectors for SynchLink.
  3. Insert the module in any 1756 chassis slot; DHRIO and RIO use the standard 1756-A4 through A17 chassis, SYNCH the same range with the PA72/PA75/PB72/PB75/PC75/PH75 supplies.
  4. Add the module to the I/O configuration in Studio 5000 and, for remote I/O, schedule the racks and block transfers before the line is started.
  5. Read the indicators at power-up; on a terminated, addressed segment a dark status indicator is a configuration or wiring fault before it is a module fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 OK  Flashing green  Power-up self-test in progress; wait for the solid state.
 OK  Off  No chassis power at the slot, or the module failed its self-test.
 Port A / B  Green solid  The port is up and exchanging data on DH+ or remote I/O.
 Port A / B  Flashing green  Port configured, no data — rack assignment or node address not matching the segment.
 Port A / B  Flashing red  Communication fault on that port: duplicate node, bad baud rate or a break in the trunk.
 Port A / B  Off  Port not configured, or no activity on the link.

Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix System User Manual) and 1756-IN050.

Replacing a legacy DH+ or remote I/O link

No successor is published for this module — the DH+ and remote I/O links it serves are installed-base networks, and the replacement path is a migration of the devices on those links to EtherNet/IP, not an exchange of a catalogue number.

Two checks decide whether the module is the right answer for a given panel. One: is the legacy traffic scheduled and within 32 connections per channel. Two: does the application need DH+ peer messaging — a DHRIO configured for remote I/O only does not carry it.

Which ControlLogix DH+, remote I/O or SynchLink module to specify

  • 1756-DHRIO — two ports, each selectable between Data Highway Plus and remote I/O. 850 mA at 5.1 V DC. The one module that covers both legacy links.
  • 1756-RIO — one remote I/O port, scanner or adapter, 32 physical racks (0…76). 450 mA at 5.1 V DC.
  • 1756-DH485 — DH-485 network communication for the 1756 chassis.
  • 1756-SYNCH — SynchLink fibre, 5 Mbps at 650 nm, 50 µs frame period, 1200 mA at 5.1 V DC, 1…300 m over 200/230 µm HCS fibre.
  • 1756-EN2T / 1756-EN2TR — the EtherNet/IP destination when a legacy link is being replaced rather than maintained.

FAQ — ControlLogix 1756-DHRIO / 1756DHRIO DH+ and Remote I/O Module

What do the two ports of the 1756-DHRIO do?

Each port is selectable independently as Data Highway Plus or remote I/O (1756-TD003 Table 13), so one module can serve a DH+ peer link and a remote I/O trunk at the same time. DH+ runs at 57.6, 115.2 or 230.4 kbps.

Can it be a remote I/O adapter as well as a scanner?

No. Table 13 lists the remote I/O function as scanner only, with 32 logical rack connections and 16 block transfer connections per channel. Where adapter behaviour is required, that is the 1756-RIO in adapter mode.

How many connections does it support?

32 connections in total (Table 13). The per-channel figures are 32 logical rack connections and 16 block transfers, so the total is reached with both channels loaded.

What is its backplane draw and isolation?

850 mA at 5.1 V DC and 1.7 mA at 24 V DC, 4.5 W and 15.4 BTU/hr. Isolation is 30 V continuous basic insulation from DHRIO A and B to the backplane and from port A to the programming port, with no isolation between port A and the programming port, type tested at 877 V DC for 60 s (Table 13).

What are its environmental limits?

Operating 0…60 °C, storage -40…85 °C, 5…95% RH non-condensing, 2 g vibration at 10…500 Hz, 30 g operating and 50 g non-operating shock, CISPR 11 Class A, ESD 6 kV contact and 8 kV air, radiated RF immunity 10 V/m from 80…2000 MHz and 3 V/m from 2000…2700 MHz, EFT ±2 kV at 5 kHz and surge ±2 kV line-earth, conducted RF 10 V rms (Table 14).

Which certifications does it carry?

c-UL-us UL E65584 and Class I Division 2 UL E194810, CSA LR54689C and LR69960C, CE to 2014/30/EU, RCM, ATEX II 3 G Ex ec IIC T4 Gc, UKEX UL22UKEX2604X, UKCA, IECEx UL 22.0063X, KC, Morocco and CCC 2020122309111998 (Table 15). FM approval is not listed for this module in that table.

Which chassis accept it and how is it wired?

1756-A4, A7, A10, A13 or A17, one slot wide (Table 13). Wiring category 2 applies on the DHRIO ports and category 3 on the local programming port; the local programming port is for temporary connection, not a permanent network drop.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications) and 1756-UM001 (ControlLogix System User Manual) and the manufacturer's product page for 1756-DHRIO. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)