Allen Bradley PLC 1756-DH485 / 1756DH485

China Allen Bradley PLC 1756-DH485 / 1756DH485 supplier
Allen Bradley PLC 1756-DH485 / 1756DH485 supplier Allen Bradley PLC 1756-DH485 / 1756DH485 supplier Allen Bradley PLC 1756-DH485 / 1756DH485 supplier Allen Bradley PLC 1756-DH485 / 1756DH485 supplier Allen Bradley PLC 1756-DH485 / 1756DH485 supplier

Large Image :  Allen Bradley PLC 1756-DH485 / 1756DH485

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-DH485 / 1756DH485

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $895.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 4 PCS
Detailed Product Description

1756-DH485 technical data PDF download 1756-DH485 ControlLogix DH-485 Communications Module | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-DH485 (also written 1756DH485) is the ControlLogix DH-485 communications module: two DH-485 channels on 9-pin D-shell connectors, 850 mA at 5.1 V DC backplane load, 4.5 W maximum dissipation, isolated at 50 V and tested to withstand 750 V DC for 60 s (1756-IN587).

The installation fact that decides most projects is that the module cannot be wired to the network directly. Each channel must be cabled to a 1761-NET-AIC advanced interface converter with a 1756-CP3 cable, and the converter connects to the DH-485 trunk. So a two-channel integration is two converters and two cables beyond the module itself.

Its function is messaging: the module sends and receives messages on DH-485 and, per the ControlLogix communication module data, does not support remote programming and monitoring. That is the boundary to state up front — an engineer expecting to program a SLC 500 across it will be disappointed.

Published specifications from 1756-IN587: backplane 850 mA at +5.1 V DC and 1.7 mA at 24 V DC, power dissipation 4.5 W maximum, thermal dissipation 15.4 BTU/hr, communication rates 19.2 Kbps default and 9600, enclosure open-style, wire 20 AWG (0.519 mm2) Belden 9463 twinaxial at conductor category 2, screw torque 0.5...0.6 Nm.

Environment: 0...60 °C operating, -40...85 °C storage, 5...95% non-condensing humidity, 2 g vibration at 10...500 Hz, 30 g operating shock, 50 g non-operating, CISPR 11 Group 1 Class A emissions. Configuration requires RSLinx 2.43 or later.

1756-CP3
Logix RS-232 programmer cable, one per DH-485 channel, active mature, UPC 612598173785
In stock
1756-DH485
DH-485 communications module, 2 channels, 850 mA at 5.1 V DC, UPC per Rockwell record
In stock
1761-NET-AIC
AIC+ converter required per DH-485 channel — not a 1756 item
In stock

 Application
 DH-485 messaging / serial programming
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-DH485
 Communication
 DH-485, 2 channels
 Display
 —
 Enclosure
 None (open-style)
 Interface
 9-pin D-shell
 Mounting
 Chassis slot
 Number Of Channels
 2
 Standard
 CE, UL, CSA
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN587 (DH-485 module installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-DH485 module product photograph 1756-DH485 channel connectors product photograph 1756-DH485 module view product photograph

Where the module sits in a typical system

The module exists to bring legacy DH-485 devices — SLC 500, MicroLogix, older operator interfaces — into a ControlLogix system without replacing the field devices. It is an integration part, and its cost in a project is the module plus two converters plus two cables per two channels.

Typical use is a line where the older controllers still run the machine and the ControlLogix rack has to exchange data with them. Messaging is enough for that; remote programming is not available through the module, so the legacy controllers keep their own maintenance route.

In a new design the question is whether DH-485 is needed at all. EtherNet/IP modules remove the converter chain entirely, and the 1756-DH485 belongs to plants with an installed base worth preserving.

Commissioning in five steps

  1. Install the module in any slot of the chassis — 1756-IN587 states that slot 0 is the leftmost slot to the right of the power supply and that the module can go in any slot. Multiple 1756-DH485 modules may share one chassis, limited by the supply rating.
  2. Connect each channel to a 1761-NET-AIC converter with a 1756-CP3 cable: the right-angle connector end goes to the AIC+, the straight end to the module. The module cannot be wired straight to the DH-485 trunk.
  3. Configure the module from RSLinx, version 2.43 or later — 1756-IN587 names that version as the tool that sets the network parameters.
  4. Use Belden 9463 twinaxial cable, 20 AWG (0.519 mm2), with conductor category 2 routing, and tighten the connector to 0.5...0.6 Nm.
  5. Set the communication rate deliberately: the published rates are 19.2 Kbps (default) and 9600. A new module on an existing network has to match the network, not the default.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  CP3 per channel  The converter connects to the module through a 1756-CP3 cable, right-angle end at the converter. Two channels means two cables.
 Check 3  Messaging, not programming  The module sends and receives messages and does not support remote programming and monitoring — plan the DH-485 work accordingly.
 Check 4  Rate matches the network  19.2 Kbps default against an existing network's rate. Set it from RSLinx 2.43 or later, not from assumption.
 Check 5  Slot and supply  Any slot in the chassis, multiple modules per chassis, limited by the power supply rating — 850 mA at 5.1 V DC each.
 Check 6  Cable and routing  Belden 9463 twinaxial, 20 AWG, conductor category 2, connectors at 0.5...0.6 Nm. Wrong cable type is a network that intermittently drops messages.

Specifications and wiring per Rockwell publication 1756-IN587 (ControlLogix DH-485 Communications Module installation instructions); product attributes per the Rockwell product record and 1756-IN050.

Replacing a serial and DH-485 connection

The DH+ and remote I/O equivalent is 1756-DHRIO, a different network and not a substitute — DH-485, DH+ and remote I/O are three separate protocols.

For serial device integration on newer platforms, a protocol converter at the device end is often the cheaper route than adding DH-485 to a ControlLogix rack.

Where the whole segment is being modernised, 1756-EN2T or 1756-CN2 modules plus new field devices replace the module, the AIC+ converters and the twinaxial trunk in one step.

Which ControlLogix EtherNet/IP module to specify

  • 1756-CP3 — the Logix family RS-232 programmer cable; used for controller programming and, per 1756-IN587, to connect each 1756-DH485 channel to a 1761-NET-AIC converter.
  • 1756-DH485 — DH-485 communications module, two 9-pin D-shell channels, 850 mA at 5.1 V DC backplane load, isolated at 50 V.
  • 1761-NET-AIC — the AIC+ converter that each DH-485 channel needs before it can reach the network; the module has no direct DH-485 terminal.
  • 1756-DHRIO — the DH+ and remote I/O scanner; a different network, not a substitute for DH-485.
  • 1756-CN2 / 1756-EN2T — current ControlNet and EtherNet/IP modules; the migration path for a network that no longer needs DH-485.

FAQ — 1756-DH485 ControlLogix DH-485 Communications Module | Rockwell

What is the 1756-DH485?

A ControlLogix DH-485 communications module with two DH-485 channels on 9-pin D-shell connectors.

Can it connect straight to a DH-485 network?

No. Each channel must go through a 1761-NET-AIC advanced interface converter, cabled with a 1756-CP3.

What is the backplane load?

850 mA at +5.1 V DC and 1.7 mA at 24 V DC, with 4.5 W maximum power dissipation (1756-IN587).

What communication rates does it support?

19.2 Kbps as default and 9600, set through RSLinx 2.43 or later.

What is the isolation rating?

50 V isolation, tested to withstand 750 V DC for 60 s.

Does it support remote programming?

No — it sends and receives messages and does not support remote programming and monitoring.

What cable does the network use?

Belden 9463 twinaxial, 20 AWG (0.519 mm2), conductor category 2, screw torque 0.5...0.6 Nm.

What are the environmental limits?

0...60 °C operating, -40...85 °C storage, 5...95% non-condensing humidity, 2 g vibration, 30 g operating shock, open-style enclosure.

How many modules fit in a chassis?

Any slot and multiple modules, limited by the power supply rating — 850 mA at 5.1 V DC per module.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-DH485. Values re-checked 15 November 2026.