logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-CPR2 / 1756CPR2

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-CPR2 / 1756CPR2

China Allen Bradley PLC 1756-CPR2 / 1756CPR2 supplier
Allen Bradley PLC 1756-CPR2 / 1756CPR2 supplier Allen Bradley PLC 1756-CPR2 / 1756CPR2 supplier Allen Bradley PLC 1756-CPR2 / 1756CPR2 supplier Allen Bradley PLC 1756-CPR2 / 1756CPR2 supplier Allen Bradley PLC 1756-CPR2 / 1756CPR2 supplier

Large Image :  Allen Bradley PLC 1756-CPR2 / 1756CPR2

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-CPR2 / 1756CPR2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $53.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-CPR2 technical data PDF download 1756-CPR2 ControlLogix Redundant Power Supply Cable 0.91 m | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-CPR2 (also written 1756CPR2) is the cable that joins a ControlLogix redundant power supply to the 1756-PSCA2 chassis adapter. Rockwell publishes it as a 0.91 m (3 ft) cable with a 12.7 cm (5.0 in.) bend radius, ordered separately from both the supply and the adapter (1756-IN620).

It is not included with the 1756-PA75R, 1756-PB75R, 1756-PAXTR or 1756-PBXTR when those are bought as individual supplies, which is why an incomplete redundant kit usually traces back to this line item. The 1756-PAR2 and 1756-PBR2 bundles are the exception — those catalogue numbers list the connection cables as included.

Two variants exist for tight layouts: 1756-CPR2D and 1756-CPR2U. Both require 10.16 cm (4.0 in.) of clearance beside the chassis adapter, where the standard CPR2 does not. The cable carries wire category 3 on its connections, and the male end plugs into the chassis adapter.

The safety point is printed as a warning, not a note: connecting or disconnecting a 1756-CPR2 while either backplane power source is on can produce an electric arc. In a hazardous location that is an explosion risk; in any location repeated arcing wears the contact pins on the cable and the mating connector, and worn contacts introduce resistance that can disturb module operation.

1756-PA75R AC redundant supply, 120/240 V AC, 13 A at 5.1 V DC, 75 W IN STOCK
1756-PB75R DC redundant supply, 24 V DC, 13 A at 5.1 V DC, 75 W IN STOCK
1756-PAXT XT AC supply, 8 A at 5.1 V DC, 42 W at -25 to +70 C IN STOCK
1756-PBXT XT DC supply, 10 A at 5.1 V DC, 52 W at -25 to +70 C IN STOCK
1756-PAXTR XT AC redundant supply, 42 W, 0-60 C in a non-XT chassis IN STOCK
1756-PA75 Non-redundant AC supply, single, 13 A at 5.1 V DC, 75 W IN STOCK

 Application
 Chassis Power
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-CPR2
 Communication
 —
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Backplane, via 1756-PSCA2
 Mounting
 Remote, cable-connected
 Number Of Channels
 —
 Standard
 CE, UL, RCM, EAC, Morocco DOC
 Sub Brand
 ControlLogix
 Type
 Redundant Power Supply
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN620 (redundant power supply instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-CPR2 redundant supply cable product photograph 1756-CPR2 connector detail product photograph 1756-CPR2 cable run product photograph

Where the module sits in a typical system

The cable is the mechanical link between two devices that are deliberately mounted in different places: the supplies in the enclosure where heat and wiring are manageable, the adapter in the chassis where the backplane connector is. Its fixed 0.91 m length defines the enclosure layout.

In service the cable is a wear item. Every connection and disconnection under load erodes the pins, so a maintenance procedure that unplugs cables to test a supply is an expensive habit. Use the annunciator contacts to identify a failed supply instead.

Because the redundancy claim excludes the cables, a spare CPR2 belongs in the spares kit next to the spare supply. It is a low-cost part that can stop a redundant rack exactly as effectively as a failed supply.

Commissioning in five steps

  1. Mount the two supplies remotely and land both on the 1756-PSCA2 chassis adapter: the adapter is a passive device and simply funnels power from one or two supplies into the single backplane power connector.
  2. Use the published cable — 1756-CPR2, 1756-CPR2D or 1756-CPR2U — and never connect or disconnect it while either backplane power source is energised: an arc at the connector is an explosion hazard in a classified area and wears the contacts.
  3. Wire the mains side with 2.5 mm² (14 AWG) 90 °C copper at 1.2 mm insulation maximum, tighten to 0.565 N·m (5 lb·in), and protect every ungrounded supply with a 15 A time-delay fuse.
  4. Keep annunciator wiring to 10 m (32.8 ft) maximum if you use the annunciator contacts, and note the wire categories: category 1 on the power ports and category 3 on the 1756-CPR2 connections.
  5. Commission by load: with both supplies healthy the pair shares the chassis current, so confirm the sharing before you rely on it. A single healthy supply must carry the entire chassis load — that is the design promise, not a margin.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  Clearance for D and U variants  1756-CPR2D and 1756-CPR2U need 10.16 cm beside the adapter. The bend radius rule still applies: 12.7 cm minimum on the cable.
 Check 3  Ordered separately  One cable per supply. A two-supply redundant assembly needs two CPR2 cables; the bundles include them, the individual supplies do not.
 Check 4  De-energise before connecting  Either backplane source on means an arc risk at the connector. Isolate first, especially in classified areas.
 Check 5  Connector orientation  The male end goes to the chassis adapter, the other end to the supply. Reversing the run does not work and the connector keying will not allow it.
 Check 6  Wiring category  Wire category 3 applies on the CPR2 connections — keep the routing separated from the power and signal classes around it.

Installation checks per Rockwell publication 1756-IN620, which covers adapter mounting, cable seating, load sharing, fusing and the chassis compatibility table and 1756-IN050.

Replacing a 1756-ENBT

The redundant DC and AC supplies share this cable: 1756-PA75R, 1756-PB75R, 1756-PAXTR and 1756-PBXTR all connect through 1756-CPR2 or its D/U variants to a 1756-PSCA2 or 1756-PSCA2XT adapter.

If a bundle is being renewed, the cables arrive with it: 1756-PAR2 for the AC assembly and 1756-PBR2 for the DC assembly both list connection cables as included.

There is no substitute part. 1756-CPR2 is the only cable the installation instructions list for connecting a redundant supply to the chassis adapter.

Which ControlLogix redundant power supply to specify

  • 1756-PA75R — AC redundant supply, 120/240 V AC nominal, 5.1 V DC at 13 A, 75 W maximum, pairs into chassis A4/B…A17/B.
  • 1756-PB75R — DC redundant supply, 24 V DC nominal (18 V minimum at the input), 5.1 V DC at 13 A, 75 W maximum, pairs into chassis A4/C…A17/C.
  • 1756-PAXTR / 1756-PBXTR — the XT redundant pair; rated 0…60 °C only when mounted in a non-XT chassis.
  • 1756-PSCA2 / 1756-PSCA2XT — the passive chassis adapter the supplies feed; one per chassis, two supply cables land on it.
  • 1756-CPR2 — the 0.91 m (3 ft) redundant supply cable; also offered as 1756-CPR2D and 1756-CPR2U.
  • 1756-PA75 / 1756-PB75 — the non-redundant single supplies; same 75 W class, no second supply and no adapter.

FAQ — 1756-CPR2 ControlLogix Redundant Power Supply Cable 0.91 m | Rockwell

What is the 1756-CPR2 used for?

Connecting a ControlLogix redundant power supply — 1756-PA75R, PB75R, PAXTR or PBXTR — to the 1756-PSCA2 or 1756-PSCA2XT chassis adapter (1756-IN620).

How long is it?

0.91 m (3 ft), with a 12.7 cm (5.0 in.) minimum bend radius.

Is the cable included with the power supply?

No when the supplies are ordered individually. The 1756-PAR2 and 1756-PBR2 bundles list the connection cables as included; a single 1756-PA75R or 1756-PB75R ships without one.

What are the CPR2D and CPR2U variants?

Alternative versions of the same cable for layouts that suit them, both requiring 10.16 cm (4.0 in.) of clearance beside the chassis adapter.

Can I unplug it while the system is running?

No. Connecting or disconnecting the cable while either backplane source is energised can arc — an explosion hazard in hazardous locations, and a cause of connector wear and contact resistance anywhere.

How many cables does a redundant rack need?

One per supply. A two-supply assembly needs two cables; each supply has its own run to the adapter.

Which end goes where?

The male end connects to the chassis adapter and the other end to the supply. The connector design does not permit the reverse.

What wiring category applies?

Wire category 3 on the 1756-CPR2 connections.

Does a spare cable matter?

Yes. The redundant system's coverage excludes the chassis adapter and the cables, so a damaged cable stops the rack even with both supplies healthy. Keep one in the spares kit.


Data sources. Technical values on this page come from Rockwell publications 1756-IN620 (ControlLogix Redundant Power Supply, installation instructions), 1756-IN619 (ControlLogix Power Supply installation instructions) and 1756-TD005 (ControlLogix power supply technical data) and the manufacturer's product page for 1756-CPR2. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)