The 1756-CN2R (also written 1756CN2R) is the redundant ControlNet bridge for the ControlLogix 1756 platform: two ControlNet BNC ports, 5 Mbps network rate, 128 Logix communication connections, chassis mounted and one slot wide. The second port carries the redundant trunk, so a single cable or tap failure on the segment does not remove the chassis from the network.
Table 22 publishes 128 Logix communication connections with 131 supported in total — three are reserved for redundant control — and 99 nodes on the network. Current draw is 1300 mA at 5.1 V DC plus 3 mA at 24 V DC, dissipating 6.7 W and 22.9 BTU/hr at approximately 0.293 kg. Isolation is 30 V continuous basic insulation between ControlNet A/B and the backplane and between A and B, type tested at 500 V AC for 60 s. Operating temperature is 0…60 °C and a 12 Mbps USB port serves local programming.
| 1756-CN2 | ControlNet bridge, 1 BNC port, 128 Logix connections | IN STOCK |
| 1756-CN2R | Redundant ControlNet bridge, 2 BNC ports, 128 Logix connections | IN STOCK |
| 1756-CN2RXT | Redundant ControlNet bridge, -25...70 C, conformal coated | IN STOCK |
| 1756-CNB | ControlNet bridge, 1 BNC port, 40...48 Logix connections | IN STOCK |
| 1756-CNBR | Redundant ControlNet bridge, 2 BNC ports, 40...48 connections | IN STOCK |
Application |
ControlNet |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-CN2R |
Communication |
ControlNet |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
2 ControlNet BNC (5 Mbps, redundant) |
Mounting |
Chassis |
Number Of Channels |
2 |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Communication Module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix system user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.
The module exists for segments where stopping is expensive: a redundant trunk pair runs from the controller chassis to the critical I/O racks, and one trunk can be lost without dropping the schedule. Media redundancy is the whole point — the connection count is unchanged from the CN2.
Two ports do not double the connection budget. The 128 Logix connections are shared across both trunks, and the three reserved connections are what the module keeps back for redundant control rather than handing to the schedule.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| OK | Flashing green | Power-up self-test in progress; wait for the solid state. |
| OK | Off | No chassis power at the slot, or the module failed its self-test. |
| ControlNet A / B | Green solid | The port is on the network and exchanging scheduled data. |
| ControlNet A / B | Flashing green | Port is connected but not scheduled, or not the keeper for that segment. |
| ControlNet A / B | Flashing red | Duplicate node address, or a configuration mismatch on that port. |
| ControlNet A / B | Off | No activity on that port: trunk unterminated, cable open, or the port is not used. |
Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix System User Manual) and 1756-IN050.
ControlNet is a legacy network in Rockwell's catalogue; the migration route published is CNET-RM001, the ControlNet to EtherNet/IP Migration Reference Manual, which replaces the segment rather than the module. No ControlNet successor is published for this part.
The practical reading for a spares decision: the redundant pair is a property of the segment design, so replacing a CN2R with an EtherNet/IP module means re-engineering the redundancy as a device-level ring on an EN2TR, with the connection budget of that module rather than 128 Logix connections.
What is the difference between the 1756-CN2 and the 1756-CN2R?
Port count and redundancy, not capacity. Both carry 128 Logix communication connections and 99 nodes at 5 Mbps; the CN2R adds a second BNC port for a redundant trunk and draws 1300 mA at 5.1 V DC against 1100 mA on the CN2 (1756-TD003 Table 22).
How much current does it draw from the backplane?
1300 mA at 5.1 V DC and 3 mA at 24 V DC, dissipating 6.7 W and 22.9 BTU/hr, one slot wide, approximately 0.293 kg (Table 22). That is 200 mA above the non-redundant CN2, which is the figure to re-check in the chassis power budget.
How does the redundancy work?
Two ControlNet trunk ports, A and B, with isolation between them as well as to the backplane — 30 V continuous basic insulation type tested at 500 V AC for 60 s (Table 22). Three of the 131 supported connections are reserved for redundant control rather than left to the schedule.
What are its environmental limits and certifications?
Operating 0…60 °C (Table 22); T4 temperature code; open-style. Certifications per Table 6: c-UL-us UL E65584 and Class I Division 2 UL E194810, CSA LR54689C and LR69960C, CE to 2014/30/EU, RCM, ATEX II 3 G Ex ec IIC T4 Gc, UKEX UL22UKEX2604X, UKCA, IECEx UL 22.0063X, FM Class I Division 2, KC, ODVA and CCC 2020122309111998.
Which chassis and wiring are approved?
Any slot of 1756-A4, A7, A10, A13 or A17 (Table 22). ControlNet trunks use 1786-RG6 quad-shield coax with the published taps and terminators; the module's USB port is for temporary local programming only.
Does the second port increase the number of devices I can connect?
No. The connection budget stays at 128 Logix connections with 131 supported in total, and the node limit stays at 99. The second port carries the same schedule over a second trunk; it does not add connections.
Is an EtherNet/IP equivalent available?
For new installations the equivalent role is an EtherNet/IP bridge such as the 1756-EN2TR, with a device-level ring replacing the redundant trunk. Rockwell publishes that migration in CNET-RM001 rather than as a direct replacement of this catalogue number.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-UM001 (ControlLogix System User Manual) and CNET-RM001 (ControlNet to EtherNet/IP Migration Reference Manual) and the manufacturer's product page for 1756-CN2R. Values re-checked 15 November 2026.