logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-CN2R / 1756CN2R

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-CN2R / 1756CN2R

China Allen Bradley PLC 1756-CN2R / 1756CN2R supplier
Allen Bradley PLC 1756-CN2R / 1756CN2R supplier Allen Bradley PLC 1756-CN2R / 1756CN2R supplier Allen Bradley PLC 1756-CN2R / 1756CN2R supplier Allen Bradley PLC 1756-CN2R / 1756CN2R supplier Allen Bradley PLC 1756-CN2R / 1756CN2R supplier

Large Image :  Allen Bradley PLC 1756-CN2R / 1756CN2R

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-CN2R / 1756CN2R

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1408.00 USD/PCS
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-CN2R technical data PDF download ControlLogix 1756-CN2R / 1756CN2R Redundant ControlNet Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-CN2R (also written 1756CN2R) is the redundant ControlNet bridge for the ControlLogix 1756 platform: two ControlNet BNC ports, 5 Mbps network rate, 128 Logix communication connections, chassis mounted and one slot wide. The second port carries the redundant trunk, so a single cable or tap failure on the segment does not remove the chassis from the network.

Table 22 publishes 128 Logix communication connections with 131 supported in total — three are reserved for redundant control — and 99 nodes on the network. Current draw is 1300 mA at 5.1 V DC plus 3 mA at 24 V DC, dissipating 6.7 W and 22.9 BTU/hr at approximately 0.293 kg. Isolation is 30 V continuous basic insulation between ControlNet A/B and the backplane and between A and B, type tested at 500 V AC for 60 s. Operating temperature is 0…60 °C and a 12 Mbps USB port serves local programming.

1756-CN2 ControlNet bridge, 1 BNC port, 128 Logix connections IN STOCK
1756-CN2R Redundant ControlNet bridge, 2 BNC ports, 128 Logix connections IN STOCK
1756-CN2RXT Redundant ControlNet bridge, -25...70 C, conformal coated IN STOCK
1756-CNB ControlNet bridge, 1 BNC port, 40...48 Logix connections IN STOCK
1756-CNBR Redundant ControlNet bridge, 2 BNC ports, 40...48 connections IN STOCK

 Application
 ControlNet
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-CN2R
 Communication
 ControlNet
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 2 ControlNet BNC (5 Mbps, redundant)
 Mounting
 Chassis
 Number Of Channels
 2
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix system user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-CN2R product photograph product photograph 1756-CN2R module product photograph 1756-CN2R module, second view product photograph

Where the module sits in a typical system

The module exists for segments where stopping is expensive: a redundant trunk pair runs from the controller chassis to the critical I/O racks, and one trunk can be lost without dropping the schedule. Media redundancy is the whole point — the connection count is unchanged from the CN2.

Two ports do not double the connection budget. The 128 Logix connections are shared across both trunks, and the three reserved connections are what the module keeps back for redundant control rather than handing to the schedule.

Commissioning in five steps

  1. Set the node address on the module before it joins the segment — the ControlNet address is the module's identity on the wire, and two modules at the same address will not both come online.
  2. Use 1786-RG6 quad-shield coax with the published connectors and terminators; control the trunk length and the number of taps against the ControlNet planning rules, not by eye.
  3. Insert the module in any 1756 chassis slot; the published chassis are 1756-A4, A7, A10, A13 and A17 (1756-TD003 Table 22).
  4. Add the module to the I/O configuration in Studio 5000 and schedule the network — an unscheduled ControlNet segment carries no I/O regardless of the wiring.
  5. Read the indicators at power-up: a module that shows no network activity on a scheduled, terminated segment is an addressing or cabling fault before it is a module fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 OK  Flashing green  Power-up self-test in progress; wait for the solid state.
 OK  Off  No chassis power at the slot, or the module failed its self-test.
 ControlNet A / B  Green solid  The port is on the network and exchanging scheduled data.
 ControlNet A / B  Flashing green  Port is connected but not scheduled, or not the keeper for that segment.
 ControlNet A / B  Flashing red  Duplicate node address, or a configuration mismatch on that port.
 ControlNet A / B  Off  No activity on that port: trunk unterminated, cable open, or the port is not used.

Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix System User Manual) and 1756-IN050.

Replacing a ControlNet segment

ControlNet is a legacy network in Rockwell's catalogue; the migration route published is CNET-RM001, the ControlNet to EtherNet/IP Migration Reference Manual, which replaces the segment rather than the module. No ControlNet successor is published for this part.

The practical reading for a spares decision: the redundant pair is a property of the segment design, so replacing a CN2R with an EtherNet/IP module means re-engineering the redundancy as a device-level ring on an EN2TR, with the connection budget of that module rather than 128 Logix connections.

Which ControlLogix ControlNet module to specify

  • 1756-CN2 — one BNC port, 128 Logix connections, 1.1 A at 5.1 V DC, 3 mA at 24 V DC. The standard bridge for a single ControlNet segment.
  • 1756-CN2R — two BNC ports for a redundant trunk, same 128 Logix connections, 1.3 A at 5.1 V DC. Three connections are reserved for redundant control.
  • 1756-CN2RXT — the redundant module in the XT range, -25…+70 °C, 1.3 A at 5.1 V DC, wired to 1786-RG6 quad-shield coax.
  • 1756-CNB — one BNC port, 40…48 Logix connections, 970 mA at 5.1 V DC. The smaller bridge for a short segment.
  • 1756-CNBR — two BNC ports, 40…48 Logix connections, 970 mA at 5.1 V DC. Redundancy at the lower connection count.
  • 1756-EN2T / EN2TR — not ControlNet parts: the EtherNet/IP equivalent when the network itself is being replaced.

FAQ — ControlLogix 1756-CN2R / 1756CN2R Redundant ControlNet Module

What is the difference between the 1756-CN2 and the 1756-CN2R?

Port count and redundancy, not capacity. Both carry 128 Logix communication connections and 99 nodes at 5 Mbps; the CN2R adds a second BNC port for a redundant trunk and draws 1300 mA at 5.1 V DC against 1100 mA on the CN2 (1756-TD003 Table 22).

How much current does it draw from the backplane?

1300 mA at 5.1 V DC and 3 mA at 24 V DC, dissipating 6.7 W and 22.9 BTU/hr, one slot wide, approximately 0.293 kg (Table 22). That is 200 mA above the non-redundant CN2, which is the figure to re-check in the chassis power budget.

How does the redundancy work?

Two ControlNet trunk ports, A and B, with isolation between them as well as to the backplane — 30 V continuous basic insulation type tested at 500 V AC for 60 s (Table 22). Three of the 131 supported connections are reserved for redundant control rather than left to the schedule.

What are its environmental limits and certifications?

Operating 0…60 °C (Table 22); T4 temperature code; open-style. Certifications per Table 6: c-UL-us UL E65584 and Class I Division 2 UL E194810, CSA LR54689C and LR69960C, CE to 2014/30/EU, RCM, ATEX II 3 G Ex ec IIC T4 Gc, UKEX UL22UKEX2604X, UKCA, IECEx UL 22.0063X, FM Class I Division 2, KC, ODVA and CCC 2020122309111998.

Which chassis and wiring are approved?

Any slot of 1756-A4, A7, A10, A13 or A17 (Table 22). ControlNet trunks use 1786-RG6 quad-shield coax with the published taps and terminators; the module's USB port is for temporary local programming only.

Does the second port increase the number of devices I can connect?

No. The connection budget stays at 128 Logix connections with 131 supported in total, and the node limit stays at 99. The second port carries the same schedule over a second trunk; it does not add connections.

Is an EtherNet/IP equivalent available?

For new installations the equivalent role is an EtherNet/IP bridge such as the 1756-EN2TR, with a device-level ring replacing the redundant trunk. Rockwell publishes that migration in CNET-RM001 rather than as a direct replacement of this catalogue number.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-UM001 (ControlLogix System User Manual) and CNET-RM001 (ControlNet to EtherNet/IP Migration Reference Manual) and the manufacturer's product page for 1756-CN2R. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)