The 1756-CN2 (also written 1756CN2) is the ControlNet bridge module for the ControlLogix 1756 platform: one ControlNet BNC port running the network at 5 Mbps, 128 Logix communication connections, chassis mounted and one slot wide. It is the module that puts a ControlLogix chassis onto a ControlNet segment, so I/O chassis, drives, panelviews and other controllers on that segment are reachable from the controller in this chassis.
The published figures are 128 Logix communication connections, 131 connections supported in total with three reserved for redundant control, 99 nodes on the network, 1100 mA at 5.1 V DC plus 3 mA at 24 V DC, 5.6 W and 19.1 BTU/hr, and a weight of approximately 0.26 kg (1756-TD003 Table 22). Isolation is 30 V continuous basic insulation between the ControlNet network and the backplane, type tested at 500 V AC for 60 s. Operating temperature is 0…60 °C. A 12 Mbps USB port on the front is for temporary local programming, not for permanent connection.
| 1756-CN2 | ControlNet bridge, 1 BNC port, 128 Logix connections | IN STOCK |
| 1756-CN2R | Redundant ControlNet bridge, 2 BNC ports, 128 Logix connections | IN STOCK |
| 1756-CN2RXT | Redundant ControlNet bridge, -25...70 C, conformal coated | IN STOCK |
| 1756-CNB | ControlNet bridge, 1 BNC port, 40...48 Logix connections | IN STOCK |
| 1756-CNBR | Redundant ControlNet bridge, 2 BNC ports, 40...48 connections | IN STOCK |
Application |
ControlNet |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-CN2 |
Communication |
ControlNet |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
1 ControlNet BNC (5 Mbps) |
Mounting |
Chassis |
Number Of Channels |
1 |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Communication Module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix system user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.
It is the slot a retrofit starts from: an existing ControlNet segment carrying 1756 I/O chassis, PowerFlex drives or a PanelView line is brought under a ControlLogix controller through this one module, without rewiring the segment.
The 128 Logix connections are the design budget. Scheduled I/O connections to every rack and drive on the segment are drawn from that figure, so the count is checked at the schedule stage — not after the network refuses to run.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| OK | Flashing green | Power-up self-test in progress; wait for the solid state. |
| OK | Off | No chassis power at the slot, or the module failed its self-test. |
| ControlNet | Green solid | The module owns the network and is exchanging scheduled data. |
| ControlNet | Flashing green | Module is on the network but not scheduled, or not the keeper — check the schedule in Studio 5000. |
| ControlNet | Flashing red | Duplicate node address on the segment, or a configuration mismatch. |
| ControlNet | Off | No network activity: trunk not terminated, cable open, or address not set. |
Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix System User Manual) and 1756-IN050.
ControlNet is described by Rockwell as a legacy network. For replacement guidance the publication points to the ControlNet to EtherNet/IP Migration Reference Manual, CNET-RM001; it does not publish a drop-in ControlNet successor for this module.
The engineering check is the segment itself, not the module. Moving a chassis to EtherNet/IP means the partner racks, drives and panels on that segment also move, and the connection budget changes from 128 Logix connections here to the EtherNet/IP figures published for the EN2T and EN2TR. A like-for-like spares replacement stays with the CN2.
What does the 1756-CN2 do in a ControlLogix system?
It connects the chassis to a ControlNet segment at 5 Mbps, giving the controller access to the I/O chassis, drives and other devices on that network. Logix communication connections are 128, connections supported in total 131, and the network holds up to 99 nodes (1756-TD003 Table 22).
How many connections can one module carry?
128 Logix communication connections, with 131 supported in total — the extra three are reserved for redundant control. Every scheduled rack and drive connection on the segment is drawn from that budget, so it is counted when the network is scheduled.
What is its backplane current draw?
1100 mA at 5.1 V DC and 3 mA at 24 V DC, dissipating 5.6 W and 19.1 BTU/hr, one slot wide, approximately 0.26 kg (Table 22). The 5.1 V figure is what the chassis power budget is checked against.
What are its environmental limits and certifications?
Operating 0…60 °C (Table 22); isolation 30 V continuous basic insulation type tested at 500 V AC for 60 s; temperature code T4; open-style. Certifications per Table 6: c-UL-us UL E65584 and Class I Division 2 UL E194810, CSA LR54689C and LR69960C, CE to 2014/30/EU, RCM, ATEX II 3 G Ex ec IIC T4 Gc, UKEX UL22UKEX2604X, UKCA, IECEx UL 22.0063X, FM Class I Division 2, KC, ODVA conformance and CCC 2020122309111998.
Which chassis accept the module?
1756-A4, A7, A10, A13 and A17, in any slot (Table 22). One slot wide, T4, open-style.
Is a USB port available for local programming?
Yes, a full-speed USB port at 12 Mbps. Table 22 states it is for temporary local programming only, not for permanent connection, and it must not be used in hazardous locations.
Can the 1756-CN2 be replaced by an EtherNet/IP module?
Not one for one. ControlNet is a legacy network and the published migration route is CNET-RM001, which moves the whole segment to EtherNet/IP. The partner racks, drives and panels have to move with it, and the connection budget changes to the EtherNet/IP figures of the EN2T or EN2TR.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-UM001 (ControlLogix System User Manual) and CNET-RM001 (ControlNet to EtherNet/IP Migration Reference Manual) and the manufacturer's product page for 1756-CN2. Values re-checked 15 November 2026.