Product Details:
Payment & Shipping Terms:
|
The 1756-HYD02 (also written 1756HYD02) is the two-axis analog module for hydraulic servo axes: an LDT (linear displacement transducer) input on a PWM start/stop interface, and a ±10 V command to the servo valve that closes the loop on the cylinder.
Published figures are 2 axes per module, 230,000 LDT counts, selectable rates of 500 Hz to 4 kHz, a transducer that must use an external interrogation signal with a 208 kHz or 625 kHz clock, binary or gray code output, 700 mA at 5.1 V DC and 2.5 mA at 24 V DC, 5.5 W and 18.77 BTU/hr, 30 V continuous isolation, and the 1756-TBS6H terminal block (1756-TD004). The servo loop is a PID with feed-forwards and directional scaling, with the velocity loop handled by the valve or the drive.
| 1756-M02AE | 2-axis analog servo module, incremental quadrature feedback | IN STOCK |
| 1756-M02AS | 2-axis analog servo module, SSI absolute feedback 8…31 bits | IN STOCK |
| 1756-HYD02 | 2-axis analog hydraulic servo module, LDT feedback | IN STOCK |
| 1756-M03SE | SERCOS module, 3 drives, position / velocity / torque | IN STOCK |
| 1756-M08SE | SERCOS module, 8 drives, position / velocity / torque | IN STOCK |
| 1756-M16SE | SERCOS module, 16 drives, position / velocity / torque | IN STOCK |
| 1756-M08SEG | SERCOS module, 8 Extended Pack Profile drives, position only | IN STOCK |
Application |
Analog servo interface motion |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-HYD02 |
Communication |
EtherNet/IP |
Display |
Digital |
Enclosure |
None (open-style) |
Interface |
1756-HYD02 |
Mounting |
Chassis |
Number Of Channels |
1756-HYD02 |
Standard |
CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ. |
Sub Brand |
ControlLogix |
Type |
Motion control module |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Hydraulic axes are where the load is a press, an injection screw, a clamping cylinder or a heavy transfer. The analog command drives a servo valve, the LDT reports the ram position, and the loop closed in the controller replaces the mechanical cam and the limit switches that used to sequence the stroke.
The rate is the specification that decides whether the axis can follow the profile: 500 Hz to 4 kHz selectable, against 5 kHz on the 1756-M02AE and the same selectable band on the 1756-M02AS. A press profile with a fast decompression step is designed around the achievable sample rate, not around the valve alone.
These are the published signal levels and limits of the module — the figures to measure against at the terminals and in the axis configuration, taken from 1756-TD004 rather than from a generic commissioning checklist.
| Indicator | State | Meaning and first action |
| Servo output | ±10 V, 16-bit | Analog command reference with 25 mV maximum offset, ±4% gain error and a minimum 5.6 kΩ resistive load. |
| Registration input | 24 V DC, current sinking | On-state 18.5…26.4 V DC, off-state 3.5 V DC maximum; 5 V input variant on-state 3.7…5.5 V DC. |
| Relay output | 24 V DC, 75 mA | Solid-state isolated relay contact, 26.4 V DC maximum, Class 2 source. |
| Isolation | 30 V continuous | User terminals to system, the figure to quote when the panel is shared with other equipment. |
| Slot load | 700 mA at 5.1 V DC | Plus 2.5 mA at 24 V DC, 5.5 W and 18.77 BTU/hr per module. |
| Terminal block | %s | Screw torque 0.4 N·m (4.4 lb·in), screwdriver width 8 mm maximum. |
| LDT counts | 230,000 | The published absolute range for this module; it is the transducer stroke resolution that decides the practical figure. |
| Interrogation clock | 208 kHz or 625 kHz | The transducer must accept an external interrogation signal at one of these clocks, in binary or gray code. |
Signal levels, loop rates, rates and terminal block data per Rockwell publication 1756-TD004B-EN-E (1756 ControlLogix Integrated Motion Modules Specifications) and 1756-IN050.
The HYD02 is the hydraulic member of the analog motion family and shares its slot, its load and its isolation with the M02AE and M02AS: 700 mA at 5.1 V DC, 5.5 W, 30 V continuous user-to-system. Converting to a SERCOS drive removes the analog valve command, not the hydraulic circuit.
Where the axis count grows past two, a second module is added; the published limit is as many as 32 axes per controller across all analog motion modules.
What feedback does the 1756-HYD02 use?
An LDT (linear displacement transducer) with a PWM start/stop interface, rising or falling edge, binary or gray code, external interrogation at 208 kHz or 625 kHz, 230,000 counts (1756-TD004).
What is the servo loop type?
PID with feed-forwards and directional scaling for position, with the velocity loop handled by the drive or valve; 32-bit floating point gain resolution.
What update rates are selectable?
500 Hz to 4 kHz, selectable, with the practical values printed as 500 Hz, 666.7 Hz, 1 kHz, 2 kHz and 4 kHz on the SSI module of the same family.
What does the module draw?
700 mA at 5.1 V DC and 2.5 mA at 24 V DC, 5.5 W dissipation, 18.77 BTU/hr thermal load.
Which terminal block and wire size?
1756-TBS6H 36-pin spring-clamp block; 0.324…2.08 mm² (22…14 AWG) stranded, 1.2 mm insulation maximum, 1756-TBE extended housing for the largest wire.
What is the command output?
±10 V analog at 16-bit resolution, 25 mV maximum offset, ±4% gain error, minimum 5.6 kΩ load, 200 kΩ output isolation.
What does the registration input do?
Optically isolated current-sinking input, 24 V DC nominal, on-state 18.5…26.4 V DC, off-state 3.5 V DC maximum, 1.2 kΩ impedance on this module.
What environment and certifications apply?
0…60 °C, -40…85 °C storage, 5…95% RH, 2 g vibration, 30 g shock; UL Listed, CSA Class I Division 2, CE and C-Tick when marked.
Data sources. Technical values on this page come from Rockwell publications 1756-TD004 (1756 ControlLogix Integrated Motion Modules Specifications). A single specification document covers the SERCOS and analog motion families, so the numbers on this page can be checked line by line in the manufacturer's table. and the manufacturer's product page for 1756-HYD02. Values re-checked 16 November 2026.