logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT

China Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT supplier
Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT supplier Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT supplier Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT supplier Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT supplier Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT supplier Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT supplier Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT supplier

Large Image :  Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-EN2TRXT / 1756EN2TRXT

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $2388.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 3 PCS
Detailed Product Description

1756-EN2TRXT technical data PDF download ControlLogix-XT 1756-EN2TRXT / 1756EN2TRXT EtherNet/IP Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-EN2TRXT (also written 1756EN2TRXT) is the dual-port EtherNet/IP module of the ControlLogix-XT range: two copper RJ45 ports rated Category 5 at 10/100 Mbps, conformal coated, rated for -25…+70 °C, chassis mounted and one slot wide. It is the harsh-environment counterpart of the 1756-EN2TR and keeps the ring function of the second port.

The XT range is a system rating, not a module rating: pairing this module with a standard 0…60 °C chassis derates the whole system to 60 °C, which is the derating rule stated in 1756-TD003. Connection capacity is 128 TCP/IP connections and 256 Logix connections; current draw is 1 A at 5.1 V DC, 5.1 W and 17.4 BTU/hr (Table 7) — the same as the standard single-port module, lower than the standard dual-port. Firmware 5.028 or later needs Studio 5000 20.01.00 and RSLinx 2.56, and runs at 25,000 packets/s with up to eight integrated-motion axes (Table 3).

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 EtherNet/IP
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-EN2TRXT
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 2 Copper RJ45 (10/100 Mbps, Category 5)
 Mounting
 Chassis
 Number Of Channels
 2
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-EN2TRXT sealed carton product photograph 1756-EN2TRXT cartons product photograph 1756-EN2TRXT carton labels product photograph

Where the module sits in a typical system

In a panel built for an unheated enclosure, a wash-down area or a plant with corrosive gases, the module is the ring node: port 1 to the upstream device, port 2 downstream, and the ring heals inside the module when one segment is lost.

The conformal coating and the -25 °C start belong to the whole XT assembly, so the module is specified together with the XT chassis and supply; on its own it does not lift a standard chassis above its own rating.

Commissioning in five steps

  1. Set the IP address before the module is inserted — BOOTP/DHCP server, or a static address written in Studio 5000 and sent on download. Duplicate-IP detection is active at all revisions (1756-TD003 Table 2).
  2. Insert the module in any 1756 chassis slot; standard supplies 1756-PA72/PA75/PB72/PB75/PC75/PH75, redundant supplies 1756-PA75R/PB75R/PSCA2.
  3. Cable the published port type — copper twisted pair to the category listed for the module, fibre to multimode LC where the module is a fibre unit — and stay inside the channel limit.
  4. Add the module to the I/O configuration in Studio 5000. The generic Ethernet module entry is enough for messaging; an EDS or Add-on Profile is needed for ring supervision or integrated motion.
  5. Power up and read the indicators. A dark network indicator with a dark link pair is an addressing or cabling fault, not a module fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 OK  Flashing green  Power-up self-test in progress; wait for the solid state.
 OK  Off  No chassis power at the slot, or the module failed its self-test.
 NET  Green solid  CIP connections established to at least one device.
 NET  Flashing green  IP address present, no CIP connection — check the connection entry in Studio 5000.
 NET  Off  No IP address; the module is not on the network yet.
 LINK 1 / LINK 2  Green solid  Port linked at 10 or 100 Mbps.
 LINK 1 / LINK 2  Off  No link on that port: cable, connector or partner port.

Indicator behaviour per Rockwell publication 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and 1756-IN050.

Replacing a 1756-ENBT

The 1756-ENBT was discontinued on 1 November 2021. In an XT panel the substitute has to stay inside the XT rating, so the EN2TRXT replaces it rather than the standard EN2T: same one-slot footprint, 128 TCP / 256 CIP against 64 / 128 on the ENBT, plus the second port for a ring.

Two checks decide the swap. The draw rises from 700 mA to 1 A at 5.1 V DC, so the XT supply budget (1756-PAXT, PBXT or PA75XT) is re-added. And the chassis must be an XT chassis — 1756-A7XT/C, A10XT/C, A7ZXT or A10ZXT — otherwise the -25…+70 °C rating collapses to the chassis rating.

Which ControlLogix EtherNet/IP module to specify

  • 1756-EN2T — single copper port, 128 TCP / 256 CIP, 1 A at 5.1 V. Star topology, lowest slot draw.
  • 1756-EN2TR — two copper ports, same connection counts, 1.2 A. DLR ring or linear chain.
  • 1756-EN2TRXT — the dual-port module in the XT range, -25…+70 °C, conformal coated.
  • 1756-EN2TP — two ports for parallel redundancy (PRP), no ring.
  • 1756-EN3TR — two ports with integrated motion up to 128 axes.
  • 1756-EN4TR — 512 TCP / 1000 I/O connections, 1 Gbps capable, CIP Security, redundant adapters.
  • 1756-EN2F — fibre port, 100 Mbps fixed, for links beyond copper distance or through high-EMI areas.

FAQ — ControlLogix-XT 1756-EN2TRXT / 1756EN2TRXT EtherNet/IP Module

What makes the 1756-EN2TRXT different from the 1756-EN2TR?

The environment, not the network function. Both carry two RJ45 ports and 128 TCP/IP connections; the XT version is conformal coated, rated -25…+70 °C and qualified to corrosive severity G3 per ANSI/ISA 71.04-2013 and CX per IEC 60721-3-3 (Table 8). Its current draw is 1 A at 5.1 V DC against 1.2 A on the standard dual-port module (Tables 4 and 7).

How is the temperature rating of an XT system determined?

By the lowest-rated component in it. 1756-TD003 states that an XT module paired with a standard chassis or supply derates the system to the lower value — a -25…+70 °C module in a 0…60 °C chassis gives 0…60 °C. The XT chassis (1756-A7XT/C, A10XT/C, A7ZXT, A10ZXT) and XT supplies are therefore part of the specification, not options.

Does the second port support a device-level ring?

Yes. Both ports can carry a DLR ring or a linear chain and the module can act as ring supervisor in a Studio 5000 project, the same as the standard 1756-EN2TR. The published cable rating for the XT dual-port module is Category 5, not Category 5E.

Can it be installed in a standard ControlLogix chassis?

It can be inserted, but the system rating drops to the chassis rating and the conformal-coating qualification no longer covers the assembly. If the panel needs the extended temperature or the corrosive-atmosphere rating, the chassis and supplies have to be XT parts as well.

What are the environmental limits and certifications of the XT module?

Operating -25…+70 °C, non-operating -40…85 °C, 5…95% RH non-condensing, conformal coated, corrosive severity G3/CX, 2 g vibration at 10…500 Hz, 30 g shock, CISPR 11 Class A, ESD 6 kV contact and 8 kV air, radiated RF immunity to 6000 MHz, EFT ±3 kV at 5 kHz and surge ±2 kV line-earth on the Ethernet ports (Table 8). Certifications: c-UL-us UL E65584 and Class I Division 2 UL E194810, CE to 2014/30/EU, RCM, ATEX 2014/34/EU II 3 G Ex ec IIC T4 Gc, UKEX UL22UKEX2604X, UKCA, IECEx UL 22.0063X, KC, ODVA conformance, CCC 2020122309111998 (Table 9).

What is the current draw and power budget of the XT module?

1 A at 5.1 V DC, 5.1 W and 17.4 BTU/hr, one slot wide, with 30 V continuous basic isolation tested according to IEC/UL 61010-1 (1756-TD003 Table 7). Compare that with the standard EN2TR at 1.2 A — the XT part is slightly lighter, so a substitution does not overload the supply.

Which XT chassis and power supplies must it be paired with?

1756-A7XT/C, A10XT/C, A7ZXT or A10ZXT chassis with the PAXT, PBXT or PA75XT supply, or the redundant PAXTR, PBXTR pairing (Tables 7 and 8). The XT chassis is the part that carries the extended temperature range; the module cannot create it on its own.

Do the XT temperature and coating ratings apply in a standard chassis?

No. The -25…+70 °C range, conformal coating and G3/CX corrosion rating are properties of the whole XT assembly (Tables 7 and 9). Fitted to a standard 1756-A7/A10 chassis the module sits inside that chassis rating, so the extended range is lost.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-EN2TRXT. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)