Product Details:
Payment & Shipping Terms:
|
The 1756-IG16 (also written 1756IG16) is the TTL input module: 16 inputs at 0...5.5 V DC with 4.1 mA per point, and — the part that catches people out — it needs an external supply of 4.5...5.5 V DC at 160 mA, in addition to a backplane load of 140 mA at 5.1 V DC and 2 mA at 24 V DC (1756-IN062).
TTL inputs are not 24 V field signals. They come from encoders, counting circuits, TTL-level sensors and from other equipment's logic outputs, and they are referenced to a 5 V rail that the module does not generate. The 160 mA external supply requirement is a panel design item, not a detail.
Isolation is 250 V continuous basic from inputs to backplane and between input groups, with no isolation between the individual inputs of a group. The module therefore protects the backplane from the field, but it does not separate TTL channels from one another.
Signal integrity matters more here than on a 24 V module. TTL edges are fast and the logic thresholds are narrow, so cable length, screening and the 0...5.5 V window all have to be respected. A 5.5 V ceiling leaves very little margin above a nominal 5 V logic rail.
1756-IB16 |
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293 |
In stock |
1756-IB16D |
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA |
In stock |
1756-IB16I |
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA |
In stock |
1756-IB16IF |
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA |
In stock |
1756-IB16ISOE |
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA |
In stock |
1756-IB32 |
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309 |
In stock |
1756-IC16 |
16 inputs, 30...60 V DC, backplane per 1756-IN062 |
In stock |
1756-IG16 |
16 TTL inputs, backplane per 1756-IN062 |
In stock |
1756-IV16 |
16 inputs, 48 V DC, backplane per 1756-IN062 |
In stock |
Application |
Discrete input |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-IG16 |
Communication |
Backplane (producer/consumer) |
Display |
— |
Enclosure |
None (open-style) |
Interface |
Removable terminal block |
Mounting |
Chassis slot |
Number Of Channels |
16 |
Standard |
CE, UL, CSA, RCM |
Sub Brand |
ControlLogix |
Type |
Digital Input Module |
UNSPSC |
— |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The IG16 is for equipment that speaks TTL: incremental encoders with line-driver outputs, counting and positioning circuits, and older numerical controls whose logic outputs are 5 V.
It is also the module for bench and test rigs where a 24 V interface would distort the signal being measured.
Because it needs its own 4.5...5.5 V supply, the panel has one more converter or regulator to document — and that supply has to be present before the module is commissioned, not after.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | 0...5.5 V DC only | This is not a 24 V module. A 24 V signal on a TTL input is an overvoltage, not an input. |
| Check 3 | 4.1 mA per point | Source current per input, printed with the 0...5.5 V DC range. |
| Check 4 | 140 mA backplane | Above the standard DC input module, on top of the external 5 V supply. |
| Check 5 | Signal integrity | Short, screened runs and correct grounding; the TTL window is narrow compared with 24 V logic. |
Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.
For 24 V DC field signals the module is 1756-IB16, which does not need an external logic supply.
For 30 V DC and above the module is 1756-IC16, and for 90...146 V DC it is 1756-IH16I.
For mixed TTL and 24 V points in one rack, separate modules are the practical answer — there is no combined TTL/24 V input module in the family.
What is the 1756-IG16?
A 16-point TTL input module, 0...5.5 V DC at 4.1 mA per point.
Does it need an external supply?
Yes — 4.5...5.5 V DC at 160 mA, printed in the 1756-IN062 specification table.
What is the backplane current?
140 mA at 5.1 V DC and 2 mA at 24 V DC.
Can it read a 24 V DC signal?
No. The input range is 0...5.5 V DC; 24 V would exceed the module's rating.
What isolation does it provide?
250 V continuous basic inputs-to-backplane and between input groups, with no isolation between individual inputs in a group.
What are typical sources?
TTL encoders, counting circuits, 5 V logic outputs from other equipment and test rigs.
Is there a harsh-environment version?
Yes — 1756-IG16K, the conformal-coated variant listed in the same publication.
What documents cover it?
1756-IN062 for installation and specifications, 1756-TD002 for technical data and 1756-UM058 for the user manual.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IG16. Values re-checked 15 November 2026.