logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IF8H / 1756IF8H

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IF8H / 1756IF8H

China Allen Bradley PLC 1756-IF8H / 1756IF8H supplier
Allen Bradley PLC 1756-IF8H / 1756IF8H supplier Allen Bradley PLC 1756-IF8H / 1756IF8H supplier Allen Bradley PLC 1756-IF8H / 1756IF8H supplier Allen Bradley PLC 1756-IF8H / 1756IF8H supplier Allen Bradley PLC 1756-IF8H / 1756IF8H supplier Allen Bradley PLC 1756-IF8H / 1756IF8H supplier

Large Image :  Allen Bradley PLC 1756-IF8H / 1756IF8H

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IF8H / 1756IF8H

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $745.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IF8H technical data PDF download 1756-IF8H ControlLogix 8 Point HART Analog Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IF8H (also written 1756IF8H) is the 8-channel HART analog input: eight differential current inputs that carry both the 4...20 mA signal and the HART digital channel, so a transmitter's secondary variables, tag and diagnostics are readable from the controller without a separate multiplexer (1756-TD002).

The module is published in two series, and the difference is not cosmetic. A series: 300 mA at 5.1 V DC and 135 mA at 24 V DC, 4.77 W, one HART modem for the whole module, 50 V basic isolation. B series: 230 mA at 5.1 V DC and 80 mA at 24 V DC, 3.1 W, one HART modem per channel, 250 V reinforced isolation.

That single line decides most projects. One modem per module means HART instruments are polled in sequence; one modem per channel means eight simultaneous HART sessions. Fifty volts of basic isolation is not a field barrier; 250 V reinforced is.

Resolution is 16 to 21 bits depending on the range configuration, and the input is current-only — this is not the module for 0...10 V signals. Technical data 1756-TD002, user manual 1756-UM009, installation instructions 1756-IN063.

1756-IF4FXOF2F
4 high-speed differential inputs + 2 outputs, 375 mA, reinforced isolation
In stock
1756-IF6CIS
6 isolated current inputs with sourcing 24 V DC loop supply
In stock
1756-IF6I
6 isolated inputs, 16-bit, 250 mA, channel-to-channel basic isolation
In stock
1756-IF8
8 single-ended / 4 differential inputs, 200 mA, 250 V basic to backplane
In stock
1756-IF8H
8 differential HART current inputs, A and B series
In stock
1756-IF16
16 single-ended / 8 differential inputs, 200 mA, 15 Hz bandwidth
In stock
1756-IF16H
16 differential HART current inputs, A and B series
In stock
1756-IRT8I
8 isolated RTD and thermocouple inputs, 24-bit, 1756-CJC required
In stock
1756-IR6I
6 isolated RTD inputs, 20-pin block, discontinued 2017
In stock
1756-IT6I
6 thermocouple inputs, two mV ranges, one CJC sensor
In stock
1756-IT6I2
6 isolated thermocouple inputs, 16-bit, two CJC sensors
In stock

 Application
 Analog input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IF8H
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 8
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Analog Input Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN063 (analog I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IF8H HART input module product photograph 1756-IF8H terminal side product photograph 1756-IF8H label detail product photograph

Where the module sits in a typical system

The IF8H is for plants that already run HART transmitters and want the digital data in the controller: device tags, ranged values, sensor diagnostics, and the second and third variables that would otherwise need extra transmitters or a handheld.

The B series is the specification for a new installation, because per-channel modems and 250 V reinforced isolation match how modern instrument loops are actually documented. The A series is the pragmatic choice for a retrofit where eight instruments are polled on a slow cycle anyway.

Where the panel only needs the 4...20 mA value, the HART capability is an unused cost; the 1756-IF8 does the measurement for 200 mA backplane and 1.74 W.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's analogue I/O instructions include keying as a step, and a block keyed for a different module will not seat.
  2. Wire signal conductors to category 2 and keep them out of the same duct as the 480 V motor feeders. The analogue front end is the part of the rack that reads induced noise as measurement.
  3. Terminate the cable shield at the panel earth, not at the module terminals. A shield carried onto the RTB becomes an antenna for the next drive cabinet.
  4. Set the notch filter to the local mains frequency — 50 Hz or 60 Hz — in the Logix Designer project. The published settling time, scan time and noise rejection figures are all quoted at a selected notch frequency.
  5. Check the field range against the module's real range, not the sensor's nominal one. An IF6I accepts 0...21 mA with overrange indication, which is wider than a 4...20 mA transmitter needs and narrower than a 0...25 mA device supplies.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  One modem or eight  On the A series HART is multiplexed through a single modem, so polling eight transmitters takes eight times as long as one. Time-critical diagnostics need the B series.
 Check 3  A series isolation is 50 V basic  Not a field barrier. A panel requiring separation between field circuits needs the B series at 250 V reinforced.
 Check 4  Current input only  No voltage range. Voltage transmitters need an IF8, IF16 or IF6I, or a signal conditioner.
 Check 5  HART needs configuration  The HART channel is commissioned in the Logix Designer project; a module installed without it measures 4...20 mA and reports nothing digital.

Specifications per Rockwell publication 1756-TD002 (ControlLogix I/O Modules Specifications); module behaviour per 1756-UM009 and 1756-IN050.

Replacing a 1756-IF6I of an earlier generation

Without HART, the 1756-IF8 measures 8 single-ended channels at 200 mA backplane and 250 V basic isolation to the backplane.

For 16 HART channels, 1756-IF16H carries 16 differential current inputs with a modem per channel on the B series.

For isolated non-HART channels, 1756-IF8I provides 8 isolated inputs at 24-bit resolution with 250 V reinforced isolation.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IF4FXOF2F — 4 high-speed differential inputs plus 2 high-speed outputs in one slot, 375 mA at 5.1 V DC, 250 V reinforced isolation.
  • 1756-IF8 — 8 single-ended (or 4 differential) inputs, 200 mA at 5.1 V DC, 250 V basic isolation to the backplane.
  • 1756-IF16 — 16 single-ended inputs, 200 mA at 5.1 V DC, same ranges as the IF8 with 15 Hz channel bandwidth.
  • 1756-IF6I — 6 individually isolated inputs, 250 mA at 5.1 V DC, 16-bit resolution, channel-to-channel isolation.
  • 1756-IF6CIS — 6 isolated current inputs with per-channel 24 V DC loop sourcing for 2-wire transmitters.
  • 1756-IF8H / 1756-IF16H — the HART variants, 8 or 16 differential current inputs, one modem per module (A series) or per channel (B series).
  • 1756-IRT8I / 1756-IR12 — RTD and thermocouple measurement, 250 V reinforced isolation, 24-bit resolution.
  • 1756-TBNH / 1756-TBCH / 1756-TBSH / 1756-TBS6H — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IF8H ControlLogix 8 Point HART Analog Input | Rockwell

What is the 1756-IF8H?

An 8-channel differential current input module with HART communication, published in A and B series.

What is the backplane current?

A series 300 mA at 5.1 V DC and 135 mA at 24 V DC (4.77 W); B series 230 mA at 5.1 V DC and 80 mA at 24 V DC (3.1 W).

What is the difference between A and B series?

A series has one HART modem per module and 50 V basic isolation; B series has one modem per channel and 250 V reinforced isolation.

What resolution does it have?

16 to 21 bits, depending on the configured range.

Does it accept voltage inputs?

No. The channels are current inputs; voltage signals need a different module or a signal conditioner.

How many HART channels can be polled at once?

One on the A series — HART is multiplexed through a single modem. Eight on the B series, one modem per channel.

What isolation does the B series provide?

250 V continuous reinforced insulation, against 50 V basic on the A series.

What documents cover it?

1756-TD002 for technical data, 1756-UM009 for the user manual and 1756-IN063 for installation.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IF8H. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)