logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IC16 / 1756IC16

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IC16 / 1756IC16

China Allen Bradley PLC 1756-IC16 / 1756IC16 supplier
Allen Bradley PLC 1756-IC16 / 1756IC16 supplier Allen Bradley PLC 1756-IC16 / 1756IC16 supplier Allen Bradley PLC 1756-IC16 / 1756IC16 supplier Allen Bradley PLC 1756-IC16 / 1756IC16 supplier Allen Bradley PLC 1756-IC16 / 1756IC16 supplier

Large Image :  Allen Bradley PLC 1756-IC16 / 1756IC16

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IC16 / 1756IC16

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $315.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IC16 technical data PDF download 1756-IC16 ControlLogix 16 Point 30-60V DC Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IC16 (also written 1756IC16) is the 16-point DC input module for higher-voltage DC circuits: 30...55 V DC at 60 °C and 30...60 V DC at 55 °C, both at 7 mA, with a backplane load of 135 mA at 5.1 V DC and 3 mA at 24 V DC (1756-IN062).

Read the two rows together and the module's real constraint appears: the top of the voltage range depends on the ambient temperature. 60 V DC is allowed at 55 °C, not at 60 °C — the derating is printed in the same cell, and a design that quotes '30...60 V DC' without the temperature is quoting half the specification.

Isolation is 250 V continuous basic from inputs to backplane and 125 V basic between input groups, with no isolation between the individual inputs of a group — the group boundary is where the 125 V stops.

This is the module for 48 V DC control circuits and for 24 V systems that sit well above the 31.2 V ceiling of the IB family. Where a panel already runs 48 V DC, the IC16 avoids a voltage converter per channel.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IC16
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IC16 module product photograph 1756-IC16 terminal side product photograph 1756-IC16 module view product photograph

Where the module sits in a typical system

The IC16 belongs on 48 V DC control circuits — older machine tools, some marine and heavy-vehicle systems, and plant where 48 V DC is the house standard. It reads those circuits directly without a per-channel converter.

It also handles 24 V systems that run high: a battery-backed 24 V rail can sit above 31 V during equalise charging, outside the IB16 window but inside the IC16's.

Because the top of its range moves with ambient, a panel that runs hot needs the 55 °C row, not the 60 °C one. Check the enclosure temperature, not the datasheet ceiling.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's DC digital I/O instructions include keying as a step, and a wrongly keyed block will not seat.
  2. Wire to conductor category 1 and keep the field wiring separated from the analogue and communication classes in the panel (1770-4.1).
  3. Check the sinking or sourcing convention against the field device before terminating. The IB family is sinking input; a sourcing sensor wired as if it were sinking gives a channel that never turns on.
  4. Verify the input voltage range against the actual field supply, not against the nominal 24 V. 10...31.2 V DC on the IB16 means a 32 V rail is outside the published range.
  5. Set the module's input filter and change-of-state configuration in the Logix Designer project before commissioning, so the first fault report is not a filtering artefact.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  7 mA per point  Higher than the IB family's 5...10 mA range, so the field burden is not the lightest option.
 Check 3  135 mA backplane  Comparable to the IB16I, and 35 % above the standard IB16.
 Check 4  125 V group isolation  Group-to-group is basic at 125 V, and there is no isolation inside a group.
 Check 5  24 V systems do not need it  For a 24 V DC field supply the IB16 covers the range at lower input current; the IC16 is for 30 V DC and above.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a 16-point input module of an earlier generation

The 10...31.2 V DC standard module is 1756-IB16 for 24 V DC circuits.

The wide-window 10...55 V DC module is 1756-IB16ISOE, which covers both 24 V and 48 V DC in one catalogue number.

For 90...146 V DC circuits the equivalent is 1756-IH16I, whose derating is expressed in channels-on versus ambient.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IB16 — 16 sinking inputs, 10...31.2 V DC, 10 mA max, backplane 100 mA at 5.1 V DC, reinforced isolation to the backplane.
  • 1756-IB16D — the diagnostic version, 10...30 V DC, 13 mA max, backplane 150 mA at 5.1 V DC, basic isolation.
  • 1756-IB16I — individually isolated inputs, 10...30 V DC, 10 mA max, backplane 135 mA at 5.1 V DC, isolation input-to-input.
  • 1756-IB32 — 32 sinking inputs in one slot, 10...31.2 V DC, 5.5 mA max, backplane 120 mA at 5.1 V DC.
  • 1756-IB16IF — fast peer-control input module, 10...30 V DC, 5 mA max, backplane 275 mA at 5.1 V DC.
  • 1756-IB16ISOE — sequence-of-events input, 10...55 V DC, 5.1 mA max, backplane 320 mA at 5.1 V DC.
  • 1756-TBNH / 1756-TBSH — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IC16 ControlLogix 16 Point 30-60V DC Input | Rockwell

What is the 1756-IC16?

A 16-point DC input module for 30...55 V DC at 60 °C and 30...60 V DC at 55 °C, at 7 mA per input.

Why are there two voltage ranges?

The published table derates the upper voltage with ambient temperature: 60 V DC is specified at 55 °C, not at 60 °C.

What is the backplane current?

135 mA at 5.1 V DC and 3 mA at 24 V DC.

What isolation does it provide?

250 V continuous basic inputs-to-backplane, 125 V basic between input groups, and no isolation between individual inputs in a group.

Can I use it on a 24 V DC system?

It would work within range, but the 1756-IB16 is the module specified for 24 V DC, with a lower input current.

Is it a 48 V DC module?

Yes — 48 V DC sits inside the 30...55 V DC range at 60 °C.

What is the input current per point?

7 mA, printed for both voltage rows.

What documents cover it?

1756-IN062 for installation and specifications, 1756-TD002 for technical data and 1756-UM058 for the user manual.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IC16. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)