Allen Bradley PLC 1756-IA16I / 1756IA16I

China Allen Bradley PLC 1756-IA16I / 1756IA16I supplier
Allen Bradley PLC 1756-IA16I / 1756IA16I supplier Allen Bradley PLC 1756-IA16I / 1756IA16I supplier Allen Bradley PLC 1756-IA16I / 1756IA16I supplier Allen Bradley PLC 1756-IA16I / 1756IA16I supplier Allen Bradley PLC 1756-IA16I / 1756IA16I supplier Allen Bradley PLC 1756-IA16I / 1756IA16I supplier Allen Bradley PLC 1756-IA16I / 1756IA16I supplier Allen Bradley PLC 1756-IA16I / 1756IA16I supplier

Large Image :  Allen Bradley PLC 1756-IA16I / 1756IA16I

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IA16I / 1756IA16I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $318.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description


1756-IA16I technical data PDF download 1756-IA16I ControlLogix 16 Point Isolated 120V AC Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IA16I (also written 1756IA16I) is the individually isolated 16-point AC input module: 120 V AC at 50/60 Hz, 15 mA per point, backplane 125 mA at 5.1 V DC and 3 mA at 24 V DC, isolation 125 V continuous basic, inputs to backplane and input to input (1756-IN064).

Read the isolation line carefully, because it is where this module differs from what its name suggests. Every input is isolated from every other input — sixteen separate barriers — but the barrier voltage is 125 V, the lowest in the AC input family, not the 250 V of the IA16 or the IM16I. It is a 120 V module with point-to-point isolation, not a general-purpose isolated input.

The individual barriers are what make it useful: each point can have its own return, its own circuit, or its own reference, and a fault on one field circuit cannot reach the others. That is the practical meaning of input-to-input isolation and the reason this module exists alongside the cheaper group-isolated IA16.

At 15 mA per point and 125 mA on the 5.1 V rail, it costs more backplane current than the IA16 for the same sixteen channels. The premium is the isolation, and the arithmetic is straightforward: sixteen isolated barriers in one slot instead of two.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IA16I
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IA16I module product photograph 1756-IA16I label product photograph 1756-IA16I terminal side product photograph

Where the module sits in a typical system

This is the module for a panel where the field circuits genuinely differ: several 120 V sources, more than one return, or signals from equipment supplied by different transformers that must not be tied together at the I/O card.

It also suits troubleshooting-driven designs. With point-to-point isolation a single field fault cannot pull a group of inputs to a false state, so a faulted sensor shows up as one bad reading rather than as a bank of them.

Where all signals come from one 120 V feed, the IA16 is cheaper and draws less backplane current, and the group isolation is sufficient. The IA16I is bought for the topology, not for the count.

Commissioning in five steps

  1. Check the module's published input current against the field device's leakage. A 120 V AC input at 13 mA will hold off a two-wire sensor that leaks a few milliamps; a low-current module will not. Input current is an immunity figure, not a burden.
  2. Decide the common arrangement before wiring, because the isolation table is per module and not per family. The IA16 has two groups of eight with 125 V between them, the IA8D has no isolation between its inputs at all, and the IA16I isolates every point — but only at 125 V.
  3. Confirm the nominal voltage against the published window, not against the panel label. The IA32 accepts 74...132 V AC, so it works on a 110 V nominal supply with deep brownout; a 240 V circuit needs the IM16I.
  4. Respect 60 °C as the surrounding-air limit and mount the module in a slot where the chassis airflow is unobstructed; every rating in 1756-IN064 is quoted at that ambient.
  5. Terminate on the 1756-TBNH or 1756-TBSH removable terminal block with 0.33...2.1 mm² (22...14 AWG) wire rated 90 °C or better, and 1.2 mm maximum insulation.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator State Meaning and first action
 Check 2 Sixteen separate returns Each input stands alone. Use that: separate circuits, separate sensors, a fault contained to one point.
 Check 3 15 mA per point Higher than the IA16's 13 mA and the highest of the 120 V group apart from the IA8D's 16 mA — more leakage immunity per point.
 Check 4 125 mA backplane A quarter more 5.1 V DC current than the group-isolated IA16 for the same channel count.
 Check 5 T4A temperature code 60 °C maximum surrounding air, same as the rest of the 120 V AC inputs.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a AC input module of an earlier generation

For group-isolated 16-point 120 V AC inputs at lower backplane current, use 1756-IA16.

For 240 V AC with input-to-input isolation at 250 V, use 1756-IM16I.

For 32 points of 74...132 V AC with group isolation, use 1756-IA32.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IA16 — 16 inputs at 120 V AC, 13 mA per point, two groups of eight with 125 V group-to-group isolation.
  • 1756-IA16I — 16 inputs individually isolated from each other, 120 V AC at 15 mA.
  • 1756-IA32 — 32 inputs in one slot, 74...132 V AC at 15 mA, the widest input window in the family.
  • 1756-IA8D — 8 inputs at 120 V AC with the highest input current, 16 mA per point.
  • 1756-IM16I — 16 isolated inputs at 240 V AC, the only 240 V AC input module published.
  • 1756-IN16 — 16 inputs at 10...30 V AC, 25 mA maximum per point.

FAQ — 1756-IA16I ControlLogix 16 Point Isolated 120V AC Input | Rockwell

What is the 1756-IA16I?

A 16-point 120 V AC input module with each input isolated from the others, 15 mA per point, backplane 125 mA at 5.1 V DC and 3 mA at 24 V DC.

What is the isolation rating?

125 V continuous basic, both inputs to backplane and input to input, as published in 1756-IN064.

Why only 125 V if every point is isolated?

The published barrier for this module is 125 V. The 250 V input-to-input rating belongs to the 240 V IM16I, which is a different module.

Can I mix different 120 V sources on one module?

Yes — that is the point of input-to-input isolation. Each point has its own barrier to the backplane and to its neighbours.

How much current does each input draw?

15 mA at 120 V AC.

How does its backplane current compare with the IA16?

125 mA against 100 mA at 5.1 V DC, for the same sixteen channels; the difference is the sixteen individual barriers.

What is the maximum ambient temperature?

60 °C surrounding air, temperature code T4A.

What wire size does the terminal block accept?

0.33...2.1 mm² (22...14 AWG) copper rated 90 °C or better, 1.2 mm maximum insulation.

Which document should I quote?

1756-IN064 for the installation and ratings table.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IA16I. Values re-checked 15 November 2026.