logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-L73XT / 1756L73XT

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-L73XT / 1756L73XT

China Allen Bradley PLC 1756-L73XT / 1756L73XT supplier
Allen Bradley PLC 1756-L73XT / 1756L73XT supplier Allen Bradley PLC 1756-L73XT / 1756L73XT supplier Allen Bradley PLC 1756-L73XT / 1756L73XT supplier Allen Bradley PLC 1756-L73XT / 1756L73XT supplier Allen Bradley PLC 1756-L73XT / 1756L73XT supplier Allen Bradley PLC 1756-L73XT / 1756L73XT supplier

Large Image :  Allen Bradley PLC 1756-L73XT / 1756L73XT

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-L73XT / 1756L73XT

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $8635.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description

1756-L73XT technical data PDF download ControlLogix-XT 1756-L73XT / 1756L73XT 8 MB Controller

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-L73XT (also written 1756L73XT) is the 8 MB ControlLogix 5570 controller built for the XT range: the same one-slot controller with the same memory and electrical figures, but shipped with extreme-temperature energy storage modules and rated for -25…+70 °C panel air instead of 0…60 °C.

The published controller table gives 8 MB user memory, 0.98 MB I/O memory, 128,000 digital, 4,000 analogue and 128,000 total I/O points as maximums, 800 mA at 5.1 V DC and 5 mA at 1.2 V DC, 2.5 W and 8.5 BTU/hr, and 30 V continuous basic isolation from the USB port to the backplane under IEC/UL 61010-1 (1756-TD001). The module list for this controller is the XT set: 1756-ESMCAPXT installed, 1756-ESMNSEXT and 1756-ESMNRMXT as alternatives.

1756-L71 ControlLogix 5570 controller, 2 MB user memory IN STOCK
1756-L72 ControlLogix 5570 controller, 4 MB user memory IN STOCK
1756-L73 ControlLogix 5570 controller, 8 MB user memory IN STOCK
1756-L71S GuardLogix 5570 safety controller, 2 MB / 1 MB safety IN STOCK
1756-L72S GuardLogix 5570 safety controller, 4 MB / 2 MB safety IN STOCK
1756-L73S GuardLogix 5570 safety controller, 8 MB / 4 MB safety IN STOCK
1756-L7SP GuardLogix 5570 safety partner, pairs with L71S / L72S / L73S IN STOCK
1756-L73XT ControlLogix-XT 5570 controller, 8 MB, -25 to +70 C IN STOCK
1756-L73SXT GuardLogix-XT 5570 safety controller, 8 MB / 4 MB safety IN STOCK
1756-L7SPXT GuardLogix-XT 5570 safety partner, pairs with L73SXT IN STOCK

 Application
 Programmable Logic Controller
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-L73XT
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1756-L73XT
 Mounting
 Chassis
 Number Of Channels
 1756-L73XT
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Controller
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix controller user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-L73XT controller product photograph 1756-L73XT controller, second view product photograph 1756-L73XT controller label product photograph

Where the module sits in a typical system

The XT variant is bought for the temperature range, not the memory. Cold-store, rooftop, skid and unheated outdoor enclosures are where the standard controller's 0 °C floor becomes the design constraint, and where the whole rack — chassis, modules, supplies — has to move to XT together.

Inside the panel the electrical budget does not change: 800 mA at 5.1 V DC, 2.5 W of dissipation and 8.5 BTU/hr are the same figures as the standard L73. What changes is the surrounding hardware, because an XT controller in a standard chassis only moves the temperature limit of one component.

Commissioning in five steps

  1. Confirm the chassis supply budget before insertion: every 5570 controller draws 800 mA at 5.1 V DC plus 5 mA at 1.2 V DC, so a rack that was planned around a 5560 controller has headroom, and a rack planned tight does not.
  2. Read the four-character status display at power-up before touching anything: TEST then PASS is a completed self-test, CHRG is the capacitor energy storage module charging, and any message other than PASS belongs in the fault log, not in a re-seat.
  3. The controller ships with a 1756-ESMCAP energy storage module already installed and with a 1 GB 1784-SD1 card in the slot. Both are removable, and a controller that will be shipped or stored needs the residual energy question answered before the ESM comes out.
  4. Load the project only after the firmware revision matches the project, then check the SD indicator: a LOAD or UPDT message means the card is being read at power-up and the card must stay in until the display clears.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 RUN  Steady green  Controller is in Run mode.
 FORCE  Off  No tags contain I/O force values, or forces are disabled.
 FORCE  Steady yellow  I/O forces are enabled. A field wiring check made now is not valid.
 FORCE  Flashing yellow  Forced addresses exist but forces are not enabled; enabling them applies every stored force at once.
 OK  Off  No power applied to the controller.
 OK  Flashing red  New controller that needs a firmware update, or a major fault on a controller in service.
 OK  Steady red  Power-up diagnostics, ESM discharge at power-down, project transfer to nonvolatile memory, or a controller that is powered but inoperable.
 OK  Steady green  Controller operating normally.
 Status display  TEST / PASS  Power-up tests running, then completed.
 Status display  CHRG  Capacitor energy storage module charging; do not remove the ESM.
 Status display  BUSY  I/O modules in the project are not yet fully powered.
 Status display  No Project  Controller memory is empty; download the project or load it from the SD card.
 Status display  Rev XX.xxx  Firmware major and minor revision currently installed.

Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and 1756-IN050.

Replacing a 1756-ENBT

As a functional replacement for a 5560 controller in an extreme-temperature panel, the L73XT takes the same slot and the same I/O. The chassis and the supply have to be the XT parts, and the energy storage modules are the XT catalogue numbers.

Within the XT range the GuardLogix equivalent is the 1756-L73SXT, which adds the safety partner pair for SIL 3 applications in the same temperature envelope.

Which ControlLogix 5570 controller to specify

  • 1756-L71 — 2 MB. Entry point of the 5570 range; the memory size that fits a single machine or a small line with no motion.
  • 1756-L72 — 4 MB. The usual minimum for a line controller with an HMI, produced/consumed tags and some recipe data.
  • 1756-L73 — 8 MB. The volume part of the family and the size most 5570 racks are built around.
  • 1756-L71S / L72S / L73S — GuardLogix versions with a separate safety memory (1 / 2 / 4 MB) alongside the standard memory.
  • 1756-L7SP — the safety partner that pairs with a GuardLogix 5570 controller to reach SIL 3 / PLe.
  • 1756-L73XT / L73SXT / L7SPXT — the same controllers and partner in the XT range for -25…+70 °C panels.

FAQ — ControlLogix-XT 1756-L73XT / 1756L73XT 8 MB Controller

What temperature range does the 1756-L73XT cover?

The XT (extreme temperature) range is rated -25…+70 °C; the standard 5570 controller is 0…60 °C. The controller must be installed with XT chassis and XT modules so the whole rack shares the rating.

Does the XT version have different memory?

No. 8 MB user memory, 0.98 MB I/O memory and the same 128,000 / 4,000 / 128,000 I/O maximums as the standard 1756-L73 (1756-TD001).

Which energy storage modules are used?

1756-ESMCAPXT, shipped installed in every XT controller; 1756-ESMNSEXT as the removable module without residual wall-clock backup; 1756-ESMNRMXT as the non-removable module that prevents USB connection and SD card removal.

Are the current draw and dissipation different?

No. 800 mA at 5.1 V DC, 5 mA at 1.2 V DC, 2.5 W and 8.5 BTU/hr are the published figures for 1756-L73XT, identical to the standard controller (1756-TD001).

What isolation does it provide?

30 V continuous, basic insulation type, from the USB port to the backplane, compliant and tested according to IEC/UL 61010-1.

Can a standard L73 simply be swapped for an XT part?

Only after the rest of the rack is checked: XT chassis, XT I/O and XT supplies. A single XT controller in a standard chassis does not extend the assembly's temperature rating.

How is firmware handled in a cold panel?

Through the SD card at power-up (UPDT on the display) or over USB in the panel. The card and the controller share the same temperature rating, so an update performed at -25 °C is inside the published envelope.

What does the status display report?

TEST then PASS at power-up, CHRG while the capacitor module charges, the firmware revision, the project name or No Project, and SAVE / LOAD / UPDT during SD card activity (1756-UM001).


Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) and 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and the manufacturer's product page for 1756-L73XT. Values re-checked 16 November 2026.

Related numbers

Contact Details