Allen Bradley PLC 1756-L64 / 1756L64 supplier Allen Bradley PLC 1756-L64 / 1756L64 supplier Allen Bradley PLC 1756-L64 / 1756L64 supplier Allen Bradley PLC 1756-L64 / 1756L64 supplier Allen Bradley PLC 1756-L64 / 1756L64 supplier Allen Bradley PLC 1756-L64 / 1756L64 supplier Allen Bradley PLC 1756-L64 / 1756L64 supplier

Large Image :  Allen Bradley PLC 1756-L64 / 1756L64

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-L64 / 1756L64

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $8035.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-L64 technical data PDF download ControlLogix 1756-L64 / 1756L64 16 MB Controller

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-L64 (also written 1756L64) is the 16 MB controller of the ControlLogix 5560 range: twice the user memory of the 1756-L63 and half that of the 1756-L65, in the same one-slot package with one RS-232 programming port and backplane access to the rack. Rockwell lists it as discontinued on 1 June 2017 under the functional replacement category, series B, UPC 612598330829, country of origin United States of America.

The 5560 envelope applies: 478 KB of I/O memory, 128,000 digital and 4,000 analogue I/O points as maximums, 32 tasks with 100 programs per task, 250 controller connections, 1200 mA at 5.1 V DC plus 14 mA at 24 V DC, 3.5 W and 11.9 BTU/hr (1756-TD001). Two published cautions come with the large-memory 5560 parts: a project loaded in an L64 or L65 can scan more slowly than the same project in the smaller controllers, and the L64 and L65 do not hold the ATEX certification the rest of the family carries.

1756-L61 5560 controller, 2 MB IN STOCK
1756-L62 5560 controller, 4 MB IN STOCK
1756-L63 5560 controller, 8 MB IN STOCK
1756-L63XT ControlLogix-XT 5560 controller, 8 MB, conformal coated IN STOCK
1756-L64 5560 controller, 16 MB IN STOCK
1756-L65 5560 controller, 32 MB IN STOCK
1756-L71 5570 controller, 2 MB IN STOCK
1756-L73 5570 controller, 8 MB IN STOCK

 Application
 Programmable Logic Controller
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-L64
 Communication
 Backplane (EtherNet/IP, ControlNet, DeviceNet, DH+, Remote I/O, SERCOS)
 Display
 Indicators (OK, RUN, I/O, FORCE, BATTERY, RS-232)
 Enclosure
 None (open-style)
 Interface
 1 RS-232 serial port
 Mounting
 Chassis
 Number Of Channels
 1
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Controller
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix controller user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-L64 controller product photograph 1756-L64, second view product photograph 1756-L64, third view product photograph

Where the controller sits in a typical system

16 MB is chosen where the program carries a large recipe or tag set but not the full cell-level scope of an L65: a converting line, a batch skid, a machine with heavy recipe management. It is the middle answer when 8 MB was outgrown and 32 MB is more than the application will ever use.

The scan-time caution matters more than the memory figure in most upgrades. A project written for an L63 and moved into an L64 does not automatically run faster; if the task structure and program density stay the same, the larger controller can take longer per scan, which is why the task periods are re-measured after the swap.

The same 250-connection ceiling applies, so the memory can grow without the connection count growing.

Commissioning in five steps

  1. Confirm the controller and chassis are on a supply that covers 1200 mA at 5.1 V DC plus 14 mA at 24 V DC, and that the battery is the one the series needs — 1756-BA1, BA1M or BATA for Series A, 1756-BA2 for Series B.
  2. Set the serial port before the first download: DF1 full duplex at the project's own settings is the default path for a programming terminal, and the port is RS-232 through a 1756-CP3 or 1747-CP3 cable.
  3. Load firmware that the project was written for, then download. A 5560 controller at an older revision rejects a project built at a newer one, so the revision is checked first.
  4. Insert the controller in any chassis slot — it is not restricted to slot 0 — and start the chassis before the I/O modules are expected online.
  5. Read the indicators after the first power-up: OK, RUN, I/O, FORCE, BATTERY and RS-232. A red I/O indicator with a running program is a module that did not come online, not a controller fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 OK  Flashing green  Power-up self-test in progress; wait for solid.
 OK  Red  Major fault or self-test failure. Read the fault in the project before any restart.
 RUN  Green solid  Program running.
 RUN  Red  Major fault latched; the program is stopped.
 I/O  Green solid  All configured I/O modules are communicating.
 I/O  Flashing green  One or more configured modules are not responding.
 I/O  Red  Faulted I/O connection; the program may still be running.
 FORCE  Amber  Forces enabled — a live wiring check is not valid while this is lit.
 BATTERY  Red  Battery low or missing; the project in RAM is not protected across a power cycle.
 RS-232  Green flashing  Serial activity on the programming port.

Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and 1756-IN050.

Replacing a controller inside an installed rack

Rockwell's notice sets the 1756-L64 discontinuation at 1 June 2017, functional replacement category. The successor families are the 5570 (1756-L71E to L73E) and the 5580 (L81E to L85E), where 16 MB of user memory sits between the L72E and L73E.

The migration is a program migration, not a module swap: the controller loses the serial port in favour of USB and Ethernet, the memory is re-sized, and every task period and motion axis is re-verified against the new scan behaviour.

Where the installed program fits a smaller memory size, an L63 or L62 replacement is simpler and keeps the enclosure budget unchanged.

Which ControlLogix 5560 controller to specify

  • 1756-L61 — 2 MB user memory. Smallest 5560 controller; enough for a line with a few I/O modules and no motion.
  • 1756-L62 — 4 MB. One step up; the usual choice where a 2 MB program left no room for edits.
  • 1756-L63 — 8 MB. The workhorse of the 5560 range, and the one most installed bases are built around.
  • 1756-L65 — 32 MB. Largest 5560 memory; scan time for a project in this controller can be slower than the same project in the smaller 5560 models.
  • 1756-L63XT — the 5560 controller in the XT range, for -25…+70 °C panels.
  • 1756-L71 / L72 / L73 (5570) — the current family, 1 MB to 32 MB with USB and higher packet rates. The functional replacement path from the 5560 controllers.

FAQ — ControlLogix 1756-L64 / 1756L64 16 MB Controller

How much user memory does the 1756-L64 have?

16 MB of user memory, with 478 KB of I/O memory and maximums of 128,000 digital and 4,000 analogue I/O points (1756-TD001).

How does it differ from the 1756-L63 and L65?

Memory only: 16 MB against 8 MB on the L63 and 32 MB on the L65. Current draw, connections and environmental limits are the same across the 5560 family.

Is the module still available new?

No — Rockwell lists the discontinuation date as 1 June 2017, replacement category functional replacement, series B.

What are the UPC and country of origin?

UPC 612598330829, country of origin United States of America, as published on the Rockwell product record.

Does a larger memory make the scan faster?

Not necessarily. Rockwell publishes the caution that a project in an L64 or L65 can scan more slowly than the same project in the smaller 5560 controllers, so task periods have to be re-measured after the swap.

Does it carry ATEX certification?

No — the L64 and L65 are the two 5560 controllers that do not hold the ATEX certification the rest of the family carries (1756-TD001).

How much current does it draw?

1200 mA at 5.1 V DC and 14 mA at 24 V DC, 3.5 W and 11.9 BTU/hr, one slot wide.

Which chassis and power supplies are approved?

1756-A4, A7, A10, A13 or A17 in any slot; standard supplies 1756-PA50, PA72, PA75, PB50, PB72, PB75, redundant 1756-PA75R / PB75R with the 1756-PSCA2 adapter.


Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) and 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and the manufacturer's product page for 1756-L64. Values re-checked 16 November 2026.

Related numbers

Contact Details