Allen Bradley PLC 1756-OH8I / 1756OH8I

China Allen Bradley PLC 1756-OH8I / 1756OH8I supplier
Allen Bradley PLC 1756-OH8I / 1756OH8I supplier Allen Bradley PLC 1756-OH8I / 1756OH8I supplier Allen Bradley PLC 1756-OH8I / 1756OH8I supplier Allen Bradley PLC 1756-OH8I / 1756OH8I supplier Allen Bradley PLC 1756-OH8I / 1756OH8I supplier

Large Image :  Allen Bradley PLC 1756-OH8I / 1756OH8I

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OH8I / 1756OH8I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $378.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1756-OH8I technical data PDF download 1756-OH8I / 1756OH8I 125V DC Isolated Output Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OH8I (also written 1756OH8I) is the ControlLogix 125 V DC isolated output module: eight outputs, each individually isolated, rated 2 A per point and 8 A per module at 60 °C, operating from 90…146 V DC.

It exists for the places where 125 V DC is already the control voltage — switchgear, battery-backed substation panels, and older plant where the DC tripping supply is 125 V rather than 24 V. Sourcing and sinking are both supported, so the module can sit on either side of the load without an external interface relay.

1756-OH8I
8 isolated 125 V DC outputs, 2 A per point
In stock
1756-OB16I
16 isolated 24 V DC outputs
In stock
1756-OW16I
16 isolated relay contacts, AC or DC
In stock
1756-OB16E
16 electronically fused 24 V DC outputs
In stock
1756-TBCH
Removable terminal block, 36 terminals
In stock

 Application
 125 V DC isolated digital output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OH8I
 Type
 Digital DC output module
 Sub Brand
 ControlLogix
 Mounting
 1756 ControlLogix chassis
 Number Of Channels
 8 individually isolated
 Voltage Category
 125 V DC sink/source
 Operating Voltage
 90…146 V DC
 Current Per Point
 2 A at 60 °C
 Current Per Module
 8 A at 60 °C
 Surge Current
 4 A for 10 ms per point, every 1 s
 Minimum Load
 2 mA per point
 Backplane Current
 210 mA at 5.1 V DC, 2 mA at 24 V DC
 Backplane Power
 1.11 W
 Power Dissipation
 3.3 W at 60 °C
 Thermal Dissipation
 11.25 BTU/hr
 Off-State Leakage
 1 mA per point
 On-State Drop
 2 V DC at 2 A
 Output Delay
 2 ms maximum, off-to-on and on-to-off
 Terminal Block
 1756-TBCH or 1756-TBS6H
 Operating Temperature
 0…60 °C (32…140 °F)

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OH8I 125 V DC output module product photograph 1756-OH8I, second view product photograph 1756-OH8I, third view product photograph

Where a 125 V DC output module sits in the panel

The point of an isolated 125 V DC output card is that the field circuit is already at a voltage the controller cannot share. Eight separate outputs mean eight separate returns, and that is what allows one chassis to drive trip coils from two different battery strings without bonding them.

The 2 A per point rating at 60 °C is unusual for a 125 V DC output: most cards in this voltage class publish 1 A or less. It suits contactor coils and small DC solenoids directly, and the 4 A for 10 ms surge per point covers the inrush of a DC coil that a steady-state rating alone would not.

The published 2 V DC on-state drop at 2 A is the number to carry into the load voltage budget. A 125 V DC coil fed through this module sees about 123 V at full current, and a panel that sized its coil for exactly 125 V has to accept that difference.

Off-state leakage is 1 mA per point. On a contactor coil that is irrelevant; on a monitoring input or an intrinsic-safety barrier it can hold a circuit in the wrong state, and the design has to account for it rather than assume a perfect open.

Because the outputs are individually isolated, the module does not need a common return bus, and that changes the wiring plan: the terminal block carries eight separate DC feeds and eight separate returns rather than one group common. The drawing is longer, and the isolation is the reason.

At 3.3 W maximum dissipation and 11.25 BTU/hr the module is not a heat source in the rack, but the 210 mA at 5.1 V backplane draw has to be counted in the chassis power budget alongside every other card in the slot list.

Commissioning in five checks

  1. Check the field supply against 90…146 V DC. The module is a 125 V DC nominal device; a 110 V DC battery string sits inside the window, a 48 V DC system does not.
  2. Keep the load above 2 mA per point. Below that the output may not hold, and the symptom is a contactor that drops out on a light circuit while a loaded one works.
  3. Do not expect group commoning. All eight outputs are individually isolated, so each point needs its own return — a shared DC common defeats the module and can create a path between separate 125 V DC sources.
  4. Respect the 2 A per point and 8 A per module at 60 °C. Unlike a 24 V DC card there is no derating curve to negotiate: the published figures are the 60 °C figures.
  5. Treat the 1 mA off-state leakage as a design value. On a 125 V DC circuit it is small, but on a monitoring input with a high impedance it is enough to read as a false on.

Leakage, drop and the ratings that decide the circuit

The published off-state leakage, on-state drop and per-point current are the numbers that decide whether this module fits a 125 V DC circuit; the indicator only confirms the command.

 Indicator  State  Meaning and first action
 OUT 0…7  Will not turn off  Off-state leakage is 1 mA per point; on a high-impedance monitoring circuit that reads as a false on.
 OUT 0…7  Voltage at the load low  On-state drop is 2 V DC at 2 A; at 125 V DC that is measurable at the terminals and should be subtracted from the load voltage budget.
 OK  Green  Module operating normally.
 Several points at once  Dead  Check the chassis supply and the 5.1 V backplane draw of 210 mA per module before condemning the card.

Output ratings and environmental limits per Rockwell publication 1756-TD002N-EN-E and 1756-IN050.

Replacing a 125 V DC output module

A dead output in this voltage class is usually the field device or the field fuse, not the module. Measure the voltage at the terminal with the output commanded on before replacing the card.

Check the 125 V DC supply under load. A battery string that reads 130 V open can fall below 90 V during a trip sequence, and the module will drop out exactly when the circuit is needed.

The module uses the 1756-TBCH or 1756-TBS6H terminal block; the wiring is individual per point, so photograph the terminations before pulling the card.

Which high-voltage DC output module to specify

  • 1756-OH8I — eight individually isolated 125 V DC outputs, 2 A per point.
  • 1756-OB16I — sixteen 24 V DC isolated outputs where the field voltage is 24 V.
  • 1756-OW16I — sixteen isolated relay contacts that switch either AC or DC.
  • 1756-OB16E — electronically fused 24 V DC outputs, faster to reset after a fault.
  • 1756-TBCH / 1756-TBS6H — the terminal blocks the OH8I uses.

FAQ — 1756-OH8I / 1756OH8I 125V DC Isolated Output Module

What is the 1756-OH8I?

A ControlLogix 125 V DC isolated output module with 8 individually isolated outputs.

What is the operating voltage range?

90…146 V DC, sourcing or sinking.

What current can each point carry?

2 A at 60 °C, with 8 A per module at 60 °C.

What surge current does it allow?

4 A for 10 ms per point, repeatable every 1 s at 60 °C.

What is the minimum load?

2 mA per point.

What does it draw from the backplane?

210 mA at 5.1 V DC and 2 mA at 24 V DC, 1.11 W total, 3.3 W maximum dissipation.

How much leakage is there when the output is off?

1 mA per point maximum.

What is the output delay?

2 ms maximum off-to-on and on-to-off.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - 1756-OH8I technical, environmental and certification data; 1756-UM058 (ControlLogix Digital I/O Modules User Manual) and the manufacturer's product page for 1756-OH8I. Values re-checked 16 November 2026.