logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-OG16 / 1756OG16

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OG16 / 1756OG16

China Allen Bradley PLC 1756-OG16 / 1756OG16 supplier
Allen Bradley PLC 1756-OG16 / 1756OG16 supplier Allen Bradley PLC 1756-OG16 / 1756OG16 supplier Allen Bradley PLC 1756-OG16 / 1756OG16 supplier Allen Bradley PLC 1756-OG16 / 1756OG16 supplier Allen Bradley PLC 1756-OG16 / 1756OG16 supplier Allen Bradley PLC 1756-OG16 / 1756OG16 supplier

Large Image :  Allen Bradley PLC 1756-OG16 / 1756OG16

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OG16 / 1756OG16

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $255.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1756-OG16 technical data PDF download 1756-OG16 ControlLogix 16 Point TTL Output Module | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OG16 (also written 1756OG16) is the 16-point TTL-level DC output module: 4.5...5.5 V DC, 24 mA per point, with a user supply of 5.5 V DC at 384 mA maximum (60 °C), backplane 210 mA at 5.1 V DC and 2 mA at 24 V DC, isolation 250 V continuous basic outputs-to-backplane and 250 V basic output group-to-group (1756-IN062).

This is the only output in the family that does not switch a field voltage. It switches 5 V logic levels, 24 mA per point, and it needs the user to supply 5.5 V DC — up to 384 mA at 60 °C — on the field side. Without that supply the module has nothing to switch.

Backplane draw is 210 mA at 5.1 V DC, modest for sixteen points, and the isolation arrangement is 250 V to the backplane and 250 V between output groups, with the points inside a group sharing a return.

Its place in a ControlLogix panel is the interface to another logic family: a TTL input card on a third-party controller, a solid-state relay board, or a drive's discrete input block that expects 5 V levels. It is a level translator, not a power output.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OG16
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OG16 module product photograph 1756-OG16 label product photograph 1756-OG16 terminal side product photograph

Where the module sits in a typical system

Use the OG16 where a ControlLogix chassis must hand on/off commands to 5 V logic: a TTL input card, a solid-state relay board, or a drive's discrete interface that is not 24 V tolerant.

Because the module switches only 24 mA, it is also the way to keep a high-count, low-current output list inside the chassis — indicator LEDs, logic gates, or opto inputs — with 384 mA of user supply covering sixteen points many times over.

Keep the 5 V runs short and away from contactor wiring. The module's isolation protects the backplane; it cannot protect the signal from noise injected downstream.

Commissioning in five steps

  1. Compare the point current at the cabinet temperature, not at 25 °C. The OB32 publishes 500 mA at 50 °C and 350 mA at 60 °C, the OB16D 2 A at 30 °C and 1 A at 60 °C, and the fast outputs 2 A at 45 °C but only 1 A at 60 °C.
  2. Check the module total, not the sum of the point ratings. The OB32 caps at 16 A per module at 50 °C and 10 A at 60 °C no matter how many points are on.
  3. Read the isolation column per module before wiring mixed supplies. The OB8 has no output-to-output isolation, the OB16E publishes 125 V, and the OB16I and OB8EI publish 250 V.
  4. A DC output driving an inductive load needs a suppression device across the load or at the contactor coil; the module's output stage is protected against the published ratings, not against an unsuppressed coil.
  5. Where the load must be monitored, the diagnostic modules compare the commanded state with the measured output and report a mismatch; a load below the module's minimum load current will read as a fault rather than as a healthy off state.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  User supply required  5.5 V DC at up to 384 mA on the field side, supplied externally.
 Check 3  24 mA per point  A TTL load budget, not a pilot duty rating — the number to use when counting solid-state relay inputs.
 Check 4  Group isolation only  250 V between output groups; the points inside a group share a common.
 Check 5  Logic-level wiring  Short, screened runs, because 5 V levels are far more sensitive to noise than 24 V circuits.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a DC output module of an earlier generation

For 24 V DC pilot duty outputs, 1756-OB16E publishes 1 A per point with 2 A inrush.

For 24 V DC at 2 A, 1756-OB16I carries 250 V reinforced isolation.

For a 24 V DC sinking arrangement, 1756-OV16E publishes 10...30 V DC at 1 A pilot duty.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OB16I — 16 points at 2 A pilot duty with 250 V reinforced isolation to the backplane and 250 V output-to-output.
  • 1756-OB16E — 16 points, 10...31.2 V DC, 1 A per point and 2 A inrush, 125 V output-to-output isolation.
  • 1756-OB16D — 16 diagnostic outputs, 2 A at 30 °C derating to 1 A at 60 °C, 19.2...30 V DC.
  • 1756-OB16IS — 16 points at 24 V DC, 2 A pilot duty, 350 mA backplane.
  • 1756-OB16IEF and 1756-OB16IEFS — 16 fast outputs, 2 A at 45 °C on up to four channels, 1 A at 60 °C.
  • 1756-OB32 — 32 points, 500 mA per channel at 50 °C and 350 mA at 60 °C, 16 A module maximum.
  • 1756-OB8 and 1756-OB8EI — 8 points at 2 A pilot duty; the EI adds output-to-output isolation.
  • 1756-OG16 — 16 TTL-level outputs, 4.5...5.5 V DC, with a 5.5 V DC user supply.
  • 1756-OV16E and 1756-OV32E — sinking outputs for a shared positive supply.

FAQ — 1756-OG16 ControlLogix 16 Point TTL Output Module | Rockwell

What is the 1756-OG16?

A 16-point TTL-level output module, 4.5...5.5 V DC at 24 mA per point, with a 5.5 V DC user supply of 384 mA.

Can it switch a 24 V DC load?

No. The output range is 4.5...5.5 V DC; 24 V loads belong on a standard DC output module.

Does it need an external supply?

Yes — 5.5 V DC at up to 384 mA at 60 °C on the user-supply terminals.

What is the per-point current?

24 mA.

How is it isolated?

250 V basic outputs-to-backplane and 250 V basic between output groups.

What is the backplane current?

210 mA at 5.1 V DC and 2 mA at 24 V DC.

What is its temperature code?

T4A under the North American classification.

Which document covers it?

1756-IN062, the ControlLogix DC digital I/O installation instructions.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OG16. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)