Product Details:
Payment & Shipping Terms:
|
The 1756-OB16IS (also written 1756OB16IS) is the 16-point DC output module: 24 V DC, 2 A pilot duty (DC-13/S0), published over 10...30 V DC for ATEX/IECEx applications, backplane 350 mA at 5.1 V DC and 2.5 mA at 24 V DC, isolation 250 V continuous basic outputs-to-backplane and 250 V basic output-to-output (1756-IN062).
The electrical ratings mirror the OB16I exactly — same 2 A pilot duty, same 350 mA on the 5.1 V rail, same 250 V pair of barriers — so the choice between them is not about current. Both are built for sixteen isolated 24 V DC outputs in one slot.
The distinction sits in the module's output timing behaviour rather than in its power stage, and that behaviour is a configuration matter: output timing, fault state and program state are set per point in the Studio 5000 project, and the module is keyed electronically rather than by jumpers.
Its 250 V output-to-output barrier is the practical feature: groups of points can be driven from separate 24 V supplies with their returns kept apart, which the OB16E cannot do beyond 125 V.
1756-IB16 |
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293 |
In stock |
1756-IB16D |
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA |
In stock |
1756-IB16I |
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA |
In stock |
1756-IB16IF |
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA |
In stock |
1756-IB16ISOE |
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA |
In stock |
1756-IB32 |
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309 |
In stock |
1756-IC16 |
16 inputs, 30...60 V DC, backplane per 1756-IN062 |
In stock |
1756-IG16 |
16 TTL inputs, backplane per 1756-IN062 |
In stock |
1756-IV16 |
16 inputs, 48 V DC, backplane per 1756-IN062 |
In stock |
Application |
Discrete output |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-OB16IS |
Communication |
Backplane (producer/consumer) |
Display |
— |
Enclosure |
None (open-style) |
Interface |
Removable terminal block |
Mounting |
Chassis slot |
Number Of Channels |
16 |
Standard |
CE, UL, CSA, RCM |
Sub Brand |
ControlLogix |
Type |
Digital Output Module |
UNSPSC |
— |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Use the OB16IS where sixteen 24 V DC outputs must be electrically isolated from one another at 250 V — separate supplies, separate returns, or a field circuit that has to stay clear of the chassis reference.
It suits machine sections whose outputs are grouped by supply, with each group fed from its own 24 V source and the barriers doing the separating rather than a common bus.
For a plain 2 A card with only 125 V between outputs, the OB16E is the lighter and cheaper fit; for diagnostics, the OB16D.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | 250 V output-to-output | Individual outputs are isolated from each other at 250 V basic. |
| Check 3 | 24 V DC nominal | 10...30 V DC range quoted for ATEX/IECEx; the standard rating is 24 V DC, 2 A. |
| Check 4 | 350 mA on the 5.1 V rail | The highest of the 16-point DC outputs, alongside the OB16I. |
| Check 5 | Per-point fault state | Configured in the project. The default on a communication loss must be set deliberately. |
Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.
For load diagnostics with electronic fusing, 1756-OB16D publishes per-point monitoring at 19.2...30 V DC.
For fast outputs with a 2 A rating at 45 °C on four channels, 1756-OB16IEFS is the published option.
For 8 points with 250 V output-to-output isolation, 1756-OB8EI halves the channel count.
What is the 1756-OB16IS?
A 16-point isolated 24 V DC output module, 2 A pilot duty, backplane 350 mA at 5.1 V DC and 2.5 mA at 24 V DC.
How does it differ from the OB16I?
The power ratings are identical; output timing behaviour is configured per point and is the practical difference between the two catalog numbers.
What isolation does it provide?
250 V continuous basic outputs-to-backplane and 250 V basic output-to-output.
What current can each point carry?
2 A pilot duty, DC-13/S0.
How much backplane current?
350 mA at 5.1 V DC and 2.5 mA at 24 V DC.
Can separate 24 V supplies drive different points?
Yes, within the 250 V output-to-output barrier.
Does it monitor the load?
No. The load-diagnostic module in this family is the 1756-OB16D.
Which document publishes the ratings?
1756-IN062, the ControlLogix DC digital I/O installation instructions.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OB16IS. Values re-checked 15 November 2026.