logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-OB16IS / 1756OB16IS

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OB16IS / 1756OB16IS

China Allen Bradley PLC 1756-OB16IS / 1756OB16IS supplier
Allen Bradley PLC 1756-OB16IS / 1756OB16IS supplier Allen Bradley PLC 1756-OB16IS / 1756OB16IS supplier Allen Bradley PLC 1756-OB16IS / 1756OB16IS supplier Allen Bradley PLC 1756-OB16IS / 1756OB16IS supplier Allen Bradley PLC 1756-OB16IS / 1756OB16IS supplier

Large Image :  Allen Bradley PLC 1756-OB16IS / 1756OB16IS

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OB16IS / 1756OB16IS

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $545.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-OB16IS technical data PDF download 1756-OB16IS ControlLogix 16 Point Isolated DC Output | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OB16IS (also written 1756OB16IS) is the 16-point DC output module: 24 V DC, 2 A pilot duty (DC-13/S0), published over 10...30 V DC for ATEX/IECEx applications, backplane 350 mA at 5.1 V DC and 2.5 mA at 24 V DC, isolation 250 V continuous basic outputs-to-backplane and 250 V basic output-to-output (1756-IN062).

The electrical ratings mirror the OB16I exactly — same 2 A pilot duty, same 350 mA on the 5.1 V rail, same 250 V pair of barriers — so the choice between them is not about current. Both are built for sixteen isolated 24 V DC outputs in one slot.

The distinction sits in the module's output timing behaviour rather than in its power stage, and that behaviour is a configuration matter: output timing, fault state and program state are set per point in the Studio 5000 project, and the module is keyed electronically rather than by jumpers.

Its 250 V output-to-output barrier is the practical feature: groups of points can be driven from separate 24 V supplies with their returns kept apart, which the OB16E cannot do beyond 125 V.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OB16IS
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OB16IS module product photograph 1756-OB16IS label product photograph 1756-OB16IS terminal side product photograph

Where the module sits in a typical system

Use the OB16IS where sixteen 24 V DC outputs must be electrically isolated from one another at 250 V — separate supplies, separate returns, or a field circuit that has to stay clear of the chassis reference.

It suits machine sections whose outputs are grouped by supply, with each group fed from its own 24 V source and the barriers doing the separating rather than a common bus.

For a plain 2 A card with only 125 V between outputs, the OB16E is the lighter and cheaper fit; for diagnostics, the OB16D.

Commissioning in five steps

  1. Compare the point current at the cabinet temperature, not at 25 °C. The OB32 publishes 500 mA at 50 °C and 350 mA at 60 °C, the OB16D 2 A at 30 °C and 1 A at 60 °C, and the fast outputs 2 A at 45 °C but only 1 A at 60 °C.
  2. Check the module total, not the sum of the point ratings. The OB32 caps at 16 A per module at 50 °C and 10 A at 60 °C no matter how many points are on.
  3. Read the isolation column per module before wiring mixed supplies. The OB8 has no output-to-output isolation, the OB16E publishes 125 V, and the OB16I and OB8EI publish 250 V.
  4. A DC output driving an inductive load needs a suppression device across the load or at the contactor coil; the module's output stage is protected against the published ratings, not against an unsuppressed coil.
  5. Where the load must be monitored, the diagnostic modules compare the commanded state with the measured output and report a mismatch; a load below the module's minimum load current will read as a fault rather than as a healthy off state.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  250 V output-to-output  Individual outputs are isolated from each other at 250 V basic.
 Check 3  24 V DC nominal  10...30 V DC range quoted for ATEX/IECEx; the standard rating is 24 V DC, 2 A.
 Check 4  350 mA on the 5.1 V rail  The highest of the 16-point DC outputs, alongside the OB16I.
 Check 5  Per-point fault state  Configured in the project. The default on a communication loss must be set deliberately.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a DC output module of an earlier generation

For load diagnostics with electronic fusing, 1756-OB16D publishes per-point monitoring at 19.2...30 V DC.

For fast outputs with a 2 A rating at 45 °C on four channels, 1756-OB16IEFS is the published option.

For 8 points with 250 V output-to-output isolation, 1756-OB8EI halves the channel count.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OB16I — 16 points at 2 A pilot duty with 250 V reinforced isolation to the backplane and 250 V output-to-output.
  • 1756-OB16E — 16 points, 10...31.2 V DC, 1 A per point and 2 A inrush, 125 V output-to-output isolation.
  • 1756-OB16D — 16 diagnostic outputs, 2 A at 30 °C derating to 1 A at 60 °C, 19.2...30 V DC.
  • 1756-OB16IS — 16 points at 24 V DC, 2 A pilot duty, 350 mA backplane.
  • 1756-OB16IEF and 1756-OB16IEFS — 16 fast outputs, 2 A at 45 °C on up to four channels, 1 A at 60 °C.
  • 1756-OB32 — 32 points, 500 mA per channel at 50 °C and 350 mA at 60 °C, 16 A module maximum.
  • 1756-OB8 and 1756-OB8EI — 8 points at 2 A pilot duty; the EI adds output-to-output isolation.
  • 1756-OG16 — 16 TTL-level outputs, 4.5...5.5 V DC, with a 5.5 V DC user supply.
  • 1756-OV16E and 1756-OV32E — sinking outputs for a shared positive supply.

FAQ — 1756-OB16IS ControlLogix 16 Point Isolated DC Output | Rockwell

What is the 1756-OB16IS?

A 16-point isolated 24 V DC output module, 2 A pilot duty, backplane 350 mA at 5.1 V DC and 2.5 mA at 24 V DC.

How does it differ from the OB16I?

The power ratings are identical; output timing behaviour is configured per point and is the practical difference between the two catalog numbers.

What isolation does it provide?

250 V continuous basic outputs-to-backplane and 250 V basic output-to-output.

What current can each point carry?

2 A pilot duty, DC-13/S0.

How much backplane current?

350 mA at 5.1 V DC and 2.5 mA at 24 V DC.

Can separate 24 V supplies drive different points?

Yes, within the 250 V output-to-output barrier.

Does it monitor the load?

No. The load-diagnostic module in this family is the 1756-OB16D.

Which document publishes the ratings?

1756-IN062, the ControlLogix DC digital I/O installation instructions.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OB16IS. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)