Allen Bradley PLC 1756-SPESMNSEXT / 1756SPESMNSEXT supplier Allen Bradley PLC 1756-SPESMNSEXT / 1756SPESMNSEXT supplier Allen Bradley PLC 1756-SPESMNSEXT / 1756SPESMNSEXT supplier Allen Bradley PLC 1756-SPESMNSEXT / 1756SPESMNSEXT supplier Allen Bradley PLC 1756-SPESMNSEXT / 1756SPESMNSEXT supplier Allen Bradley PLC 1756-SPESMNSEXT / 1756SPESMNSEXT supplier

Large Image :  Allen Bradley PLC 1756-SPESMNSEXT / 1756SPESMNSEXT

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-SPESMNSEXT / 1756SPESMNSEXT

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $143.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-SPESMNSEXT technical data PDF download 1756-SPESMNSEXT / 1756SPESMNSEXT XT Safety Partner ESM

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-SPESMNSEXT (also written 1756SPESMNSEXT) is the extreme-temperature version of the removable safety-partner energy storage module: capacitor-based, no WallClockTime backup, 300 mA at 5.1 V DC, temperature code T4.

It is the part for GuardLogix-XT panels, where the controller and the safety partner operate outside the standard 0…60 °C enclosure rating.

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 Energy storage module for safety partner
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-SPESMNSEXT
 Current Draw
 300 mA at 5.1 V DC
 Removable
 Yes
 WallClockTime Backup
 No
 Memory Limit
 1756-L73 (8 MB) or smaller
 Type
 Capacitor energy storage module
 Sub Brand
 GuardLogix
 Enclosure
 None (open-style)
 Temperature Code
 T4
 Operating Temperature
 0…60 °C (32…140 °F)
 Non-Operating Temperature
 -40…85 °C (-40…185 °F)
 Relative Humidity
 5…95%, non-condensing
 Vibration
 2 g @ 10…500 Hz
 Shock, Operating
 30 g
 Shock, Non-Operating
 50 g
 Certification
 c-UL-us, CE, RCM, ATEX/IECEx zone 2, UKEx, UKCA, KC, CCC

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-SPESMNSEXT energy storage module product photograph 1756-SPESMNSEXT, second view product photograph 1756-SPESMNSEXT, third view product photograph

Where the ESM sits on the safety partner

The XT suffix is not cosmetic. It marks the variant that belongs in a ControlLogix-XT or GuardLogix-XT chassis, and the standard SPESMNSE is not the substitute for it in a -25…+70 °C installation.

The transport rule is identical to the standard version: residual stored energy must fall to 40 µJ or less, which the publication sets at a wait of at least 20 minutes before the module or the controller is taken out of the application.

The same memory restriction applies — a 1756-L73 (8 MB) or smaller controller. In an XT panel that usually means the 1756-L73XT, which is the 8 MB XT controller.

Current draw is 300 mA at 5.1 V, identical to the non-XT removable module; the extreme-temperature qualification changes the environmental envelope, not the electrical figure.

There is no WallClockTime backup in this ESM either. An application that depends on the clock surviving a power cycle needs the capacitor ESM supplied with the controller, not this part.

Certification follows the safety-partner ESM family: c-UL-us with Class I Division 2, CE to EN 61326-1 and EN 61131-2, RCM, ATEX and IECEx zone 2 (Ex ec IIC T4 Gc), UKEx, UKCA, KC and CCC, with temperature code T4 and an open-style enclosure.

Commissioning in five checks

  1. Decide the transport rule at project level, not at the machine. If the site requires residual energy to be 40 µJ or less before the controller leaves the panel, only the NSE (removable) ESM lets you comply by waiting.
  2. Allow the full 20 minutes. The publication gives no shorter interval, and a controller moved sooner is the classic cause of a 'dead' chassis at the receiving end.
  3. Choose the NRM version only where security beats serviceability. It permanently disables the USB port and SD card use, and an SD card fitted before it becomes non-removable.
  4. Check the controller memory limit before fitting an NSE ESM: it is published for 1756-L73 (8 MB) or smaller memory controllers only.
  5. Confirm XT or standard at the same time as the controller. The XT variants exist for the -XT chassis and are not a cosmetic difference.

Transport rules, access control and ESM faults

An energy storage module has no status display; the relevant facts are the depletion wait before transport, whether the part is removable, and whether USB and SD access are blocked.

 Indicator  State  Meaning and first action
 Safety partner reports no partner after a swap  —  The ESM belongs to the L7SP safety partner, not to the standard controller; a standard 1756-ESM in that slot is the wrong part.
 USB port dead after maintenance  —  1756-SPESMNRM and SPESMNRMXT permanently disable the USB connection and SD card use by design.
 SD card will not come out  —  An SD card installed before the NRM ESM was fitted remains functional but is no longer removable.

Description, current draw and environmental figures per Rockwell publication 1756-TD001-EN-P and 1756-IN050.

Replacing an energy storage module

Match the XT suffix to the chassis. A standard ESM in an XT panel is outside the published envelope.

Observe the 20 minute depletion wait before removal from the application.

Verify the controller memory size; the L73 8 MB limit is published for this family.

Which energy storage module to specify

  • 1756-SPESMNSE — removable capacitor ESM for the L7SP safety partner.
  • 1756-SPESMNRM — the same energy storage with USB and SD access permanently blocked.
  • 1756-SPESMNSEXT / SPESMNRMXT — extreme-temperature versions for GuardLogix-XT.
  • 1756-ESMNSE / ESMNRM — the standard-side equivalents for 1756-L6x and L7x controllers.
  • 1756-ESMCAP — the capacitor ESM shipped with a new controller with WallClockTime backup retained.

FAQ — 1756-SPESMNSEXT / 1756SPESMNSEXT XT Safety Partner ESM

What is the 1756-SPESMNSEXT?

The extreme-temperature removable capacitor ESM for the 1756-L7SPXT safety partner.

What current does it draw?

300 mA at 5.1 V DC.

Does it back up the WallClockTime?

No.

How long before removal?

At least 20 minutes, until residual energy is 40 µJ or less.

Which chassis is it for?

ControlLogix-XT and GuardLogix-XT chassis and their -XT controllers.

Is it the same as 1756-SPESMNSE?

Electrically similar, but the XT variant covers the extended temperature envelope.

What is the temperature code?

T4.

Which controller memory size is supported?

1756-L73 (8 MB) or smaller.


Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) - GuardLogix 5570 safety partner energy storage modules, current draw, environmental and certification data for 1756-SPESMNSEXT and the manufacturer's product page for 1756-SPESMNSEXT. Values re-checked 16 November 2026.