Product Details:
Payment & Shipping Terms:
|
The 1756-SPESMNRM (also written 1756SPESMNRM) is the non-removable capacitor energy storage module for the 1756-L7SP safety partner. It secures the controller by permanently preventing USB connection and SD card use, and draws 330 mA at 5.1 V DC.
Where the NSE version is about transport compliance, this part is about access control: once fitted, the controller cannot be reached through the USB port or an SD card again.
| 1756-EN2F | CLX HI CAP EIP MOD - FBR | IN STOCK |
| 1756-EN2T | ControlLogix Hi Capacity ENET/IP | IN STOCK |
| 1756-EN2TR | 2-PORT CLX HI-CAP ENET/IP MODULE - TP | IN STOCK |
| 1756-EN2TRXT | CLX ENET/IP Module - 2TP -X Envt | IN STOCK |
| 1756-EN2TSC | EtherNet/IP Hi Prof Sngl Port VPN Bridge | IN STOCK |
| 1756-EN2TXT | CLX ENET/IP MODULE - TP, X-ENVT | IN STOCK |
| 1756-EN3TR | ControlLogix Ethernet Motion Module | IN STOCK |
| 1756-ENBT | ControlLogix Communication Module | IN STOCK |
| 1756-EWEB | ControlLogix Web Server Module | IN STOCK |
| 1756-EXT | ControlLogix Backplane Extender | IN STOCK |
| 1756-HIST1G | Historian ME 1 Gig in ControlLogix Rack | IN STOCK |
| 1756-HIST2G | Historian ME 2 Gig in ControlLogix Rack | IN STOCK |
| 1756-HSC | ControlLogix High-Speed Counter Module | IN STOCK |
| 1756-HYD02 | ControlLogix Analog Combination Module | IN STOCK |
Application |
Energy storage module for safety partner |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-SPESMNRM |
Current Draw |
330 mA at 5.1 V DC |
Removable |
No |
WallClockTime Backup |
No |
Memory Limit |
1756-L73 (8 MB) or smaller |
Type |
Capacitor energy storage module |
Sub Brand |
GuardLogix |
Enclosure |
None (open-style) |
Temperature Code |
T4 |
Operating Temperature |
0…60 °C (32…140 °F) |
Non-Operating Temperature |
-40…85 °C (-40…185 °F) |
Relative Humidity |
5…95%, non-condensing |
Vibration |
2 g @ 10…500 Hz |
Shock, Operating |
30 g |
Shock, Non-Operating |
50 g |
Certification |
c-UL-us, CE, RCM, ATEX/IECEx zone 2, UKEx, UKCA, KC, CCC |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The behaviour is deliberately irreversible. Rockwell publishes that the module permanently prevents the USB connection and SD card use — it is not a setting that can be reversed in the field, and it is the reason the part is specified at FAT rather than retrofitted casually.
One detail decides whether an existing SD card survives: if the card was installed before the NRM module was inserted, it remains functional but is no longer removable. A card fitted after the module is in place cannot be used at all.
Current draw is 330 mA at 5.1 V, slightly higher than the 300 mA of the removable NSE version. On a chassis budget that difference matters only at the margin, but it is published rather than rounded.
It is non-removable, so the 20 minute depletion wait published for the removable module does not apply to taking it out — the part stays with the controller, and the controller is replaced or serviced as a unit.
The safety-partner pairing is the same as the rest of the SP series: this ESM fits the 1756-L7SP, not the standard controller, and the standard-side equivalent is 1756-ESMNRM.
Environmental and certification data match the GuardLogix 5570 safety partner ESM family: 0…60 °C operating, -40…85 °C non-operating, 5…95% RH, 2 g vibration, 30 g/50 g shock, with c-UL-us Class I Division 2, CE, RCM, ATEX and IECEx zone 2, UKEx, UKCA, KC and CCC.
An energy storage module has no status display; the relevant facts are the depletion wait before transport, whether the part is removable, and whether USB and SD access are blocked.
| Indicator | State | Meaning and first action |
| Safety partner reports no partner after a swap | — | The ESM belongs to the L7SP safety partner, not to the standard controller; a standard 1756-ESM in that slot is the wrong part. |
| USB port dead after maintenance | — | 1756-SPESMNRM and SPESMNRMXT permanently disable the USB connection and SD card use by design. |
| SD card will not come out | — | An SD card installed before the NRM ESM was fitted remains functional but is no longer removable. |
Description, current draw and environmental figures per Rockwell publication 1756-TD001-EN-P and 1756-IN050.
Treat replacement as a controller-level decision. The ESM cannot be removed without taking the controller out of service.
Do not plan to reuse an SD card after fitting the NRM module; only a card already installed beforehand stays functional, and it stays in place.
Confirm the part number: the standard-side 1756-ESMNRM does not fit the safety partner.
What is the 1756-SPESMNRM?
A non-removable capacitor energy storage module for the 1756-L7SP safety partner that permanently disables USB and SD card use.
What current does it draw?
330 mA at 5.1 V DC.
Can the USB port be re-enabled?
No — the block is permanent by design.
What happens to an SD card already installed?
It remains functional but is no longer removable.
Is it removable from the controller?
No, the module is non-removable.
Which controller does it fit?
The 1756-L7SP safety partner in a GuardLogix 5570 system.
What is the standard-side equivalent?
1756-ESMNRM.
Is there an extreme-temperature version?
Yes, 1756-SPESMNRMXT.
Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) - GuardLogix 5570 safety partner energy storage modules, current draw, environmental and certification data for 1756-SPESMNRM and the manufacturer's product page for 1756-SPESMNRM. Values re-checked 16 November 2026.