logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-RM2XT / 1756RM2XT

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-RM2XT / 1756RM2XT

China Allen Bradley PLC 1756-RM2XT / 1756RM2XT supplier
Allen Bradley PLC 1756-RM2XT / 1756RM2XT supplier Allen Bradley PLC 1756-RM2XT / 1756RM2XT supplier Allen Bradley PLC 1756-RM2XT / 1756RM2XT supplier Allen Bradley PLC 1756-RM2XT / 1756RM2XT supplier Allen Bradley PLC 1756-RM2XT / 1756RM2XT supplier Allen Bradley PLC 1756-RM2XT / 1756RM2XT supplier

Large Image :  Allen Bradley PLC 1756-RM2XT / 1756RM2XT

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-RM2XT / 1756RM2XT

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $3765.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-RM2XT technical data PDF download 1756-RM2XT / 1756RM2XT Extreme-Temperature Redundancy Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-RM2XT (also written 1756RM2XT) is the ControlLogix-XT redundancy module. Electrically it matches the standard 1756-RM2 at 1.16 A on 5.1 V DC and 3.4 mA on 24 V DC; what changes is the chassis it fits and the environment it survives.

It is the part for redundant pairs built in 1756-A7XT or 1756-A10XT chassis, where the standard RM2 is outside the published mounting scope.

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 Controller redundancy module, XT
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-RM2XT
 Current Draw
 1.16 A @ 5.1 V DC; 3.4 mA @ 24 V DC
 Power Dissipation
 6 W, max
 Thermal Dissipation
 21 BTU/hr
 Slot Width
 1 slot
 Module Location
 Chassis-based, any slot
 Chassis
 1756-A7XT, 1756-A10XT
 Controller Families
 ControlLogix 5570, ControlLogix 5580
 Connector Cables
 1756-RMC1 (1 m), 1756-RMC3 (3 m), 1756-RMC10 (10 m)
 Power Supply, Standard
 1756-PAXT, 1756-PBXT
 Mounting
 ControlLogix-XT chassis, single-slot

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-RM2XT redundancy module product photograph 1756-RM2XT, second view product photograph 1756-RM2XT, third view product photograph

Where the module sits in a redundancy pair

The chassis list is short and specific: 1756-A7XT and 1756-A10XT. A standard 1756-RM2 does not appear on that list, and a mixed rack of standard and XT chassis is not a supported redundant pair.

The supply list changes with it. The XT pair is fed from 1756-PAXT and 1756-PBXT, and the publication lists no redundant supply set for the XT variant — the redundancy in the supply path is a separate decision.

Power and thermal figures are identical to the standard module: 1.16 A at 5.1 V, 3.4 mA at 24 V, 6 W maximum dissipation, 21 BTU/hr. Two modules still cost 2.32 A on the 5.1 V rail.

The pairing rule does not relax in XT installations. Both modules must carry the same catalogue number, so an XT pair is two RM2XT modules, not one RM2 plus one RM2XT.

Cabling is shared with the rest of the family: 1756-RMC1, RMC3 and RMC10, ordered separately. In a cold or hot enclosure the cable is usually the first item to be re-specified, because its service temperature is outside the module's rating.

Supported controllers are ControlLogix 5570 and 5580, the same as the standard module, so an XT redundancy upgrade does not change the controller family.

Commissioning in five checks

  1. Order modules in pairs of the same catalogue number. Rockwell states the pair must match; redundancy does not function across RM2 and RM3.
  2. Order the cables separately. No redundancy module ships with fiber, and RM3-2SFP ships with transceivers but still no cable.
  3. Match fiber to the SFP: 8.5/125 µm singlemode, or 62.5/125 and 50/125 µm multimode. A wrong fiber type passes a visual inspection and fails the link.
  4. Budget the supply before fitting the pair. Two RM2 modules cost 2.32 A on the 5.1 V rail, which is a large share of a 10 A supply.
  5. Confirm the chassis series. RM2 covers 1756-A4 through 1756-A17; the XT variant covers the 1756-A7XT and 1756-A10XT only.

Redundancy faults and what they mean

A redundancy fault is almost always a pairing, fiber or supply problem; the module pair tolerates a failed chassis, not a mismatched cable.

 Indicator  State  Meaning and first action
 Redundancy module shows a link fault  —  Check the LC connector and the fiber type against the SFP fitted; singlemode and multimode fiber are not interchangeable.
 Module draws more than expected from the chassis supply  —  1756-RM2 draws 1.16 A at 5.1 V plus 3.4 mA at 24 V, and 1756-RM3 draws 1 A at 5.1 V plus 5 mA at 1.2 V.
 Swap of one chassis does not restore redundancy  —  The cable must be re-terminated on the replacement module; a loose LC ferrule reads as a link failure even when the module is healthy.

Current draw, dissipation, connector and cable data per Rockwell publication 1756-TD001-EN-P and 1756-IN050.

Replacing a redundancy module or cable

Match the XT suffix to the chassis before ordering; the mounting list is published and short.

Keep both modules the same catalogue number when replacing one of a pair.

Recheck the XT supply loading after adding the second module.

Which redundancy part to specify

  • 1756-RM2 — standard chassis, 1.16 A at 5.1 V, 6 W dissipation, 21 BTU/hr.
  • 1756-RM3 — 1 A at 5.1 V, dual LC fiber at 1000 Mbps, -3 dB optical output.
  • 1756-RM2XT — the same module for 1756-A7XT and 1756-A10XT chassis.
  • 1756-RMC1 / RMC3 / RMC10 — the connector cables, 1 m, 3 m and 10 m.
  • 1756-PA75R / PB75R / PSCA2 — the redundant supply set used with RM2 pairs.

FAQ — 1756-RM2XT / 1756RM2XT Extreme-Temperature Redundancy Module

What is the 1756-RM2XT?

The redundancy module for ControlLogix-XT redundant chassis pairs.

What current does it draw?

1.16 A at 5.1 V DC and 3.4 mA at 24 V DC.

Which chassis does it fit?

1756-A7XT and 1756-A10XT.

Which power supplies are used?

1756-PAXT and 1756-PBXT.

Is it different from 1756-RM2 electrically?

No, the current and dissipation figures are the same.

Which cables does it use?

1756-RMC1, RMC3 or RMC10, ordered separately.

How much does it dissipate?

6 W maximum, 21 BTU/hr.

Which controllers are supported?

ControlLogix 5570 and 5580.


Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) - redundancy module current draw, dissipation, chassis and cable data for 1756-RM2XT and the manufacturer's product page for 1756-RM2XT. Values re-checked 16 November 2026.

Related numbers