The 1794-IV16 takes 16 sourcing inputs at 24V DC — the counterpart of the sinking 1794-IB16, for sensors that switch the positive rail.
The distinction is wiring, not function: a sourcing input expects the field device to deliver +24V to the terminal, so the common sits on the module side.
| 1794-IB8 | 8-point 24V DC sinking input module | IN STOCK |
| 1794-IB16 | 16-point 24V DC sinking input module | IN STOCK |
| 1794-IB32 | 32-point 24V DC sinking input module | IN STOCK |
| 1794-IB10XOB6 | 10 inputs / 6 sourcing outputs, 24V DC combo module | IN STOCK |
| 1794-IB16XOB16P | 16 inputs / 16 protected sourcing outputs combo module | IN STOCK |
| 1794-IB16D | 16-point diagnostic sinking input module | IN STOCK |
| 1794-IB16XT | 16-point 24V DC sinking input, extended temperature | IN STOCK |
| 1794-IB10XOB6XT | 10 inputs / 6 sourcing outputs, extended temperature | IN STOCK |
| 1794-IA8 | 8-point 120V AC input module | IN STOCK |
| 1794-IA16 | 16-point 120V AC input module | IN STOCK |
| 1794-IC16 | 16-point 48V DC sinking input module | IN STOCK |
| 1794-IG16 | 16-point 5V DC TTL input module | IN STOCK |
| 1794-IH16 | 16-point 125V DC sinking input module | IN STOCK |
| 1794-IM8 | 8-point 240V AC input module | IN STOCK |
| 1794-IM16 | 16-point 240V AC input module | IN STOCK |
| 1794-IV16 | 16-point 24V DC sourcing input module | IN STOCK |
| 1794-IV32 | 32-point 24V DC sourcing input module | IN STOCK |
Application |
FLEX I/O 24V DC sourcing input |
Cat Num |
1794-IV16 |
Brand Name |
Rockwell |
Number of inputs |
16, nonisolated, sourcing |
On-state voltage |
10V DC min, 24V DC nom, 31.2V DC max |
On-state current |
2.0 mA min, 8.0 mA @ 24V, 11 mA max |
Off-state voltage, max |
5V DC |
Input impedance |
4.7 k ohm max |
Isolation |
type tested 2121V DC for 1 s |
Filter time |
0.25...32 ms, selectable, 0.25 ms default |
Terminal base |
1794-TB3, 1794-TB3K, 1794-TB3S |
Operating temperature |
-20...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
<10...31.2V DC on-state, 8.0 mA at 24V nominal, with 2.0 mA at threshold and 11 mA maximum.
Off-state below 5V DC, 4.7 k ohm maximum input impedance, the figure that fixes leakage tolerance.
16 nonisolated sourcing inputs, 16 field-side indicators.
Keyswitch position 9 on the terminal base, as the installation instructions require.
Inputs on A-0...A-15, commons on B-16...B-33, power on C-34...C-51.
2-wire sourcing devices use the input and common terminals, 3-wire devices also use the power terminal.
Commons and the +V terminals are internally connected within the base.
The base is limited to 10 A total, so heavy field loads need separate supply connections.
Filter times 0.25, 0.5, 1, 2, 4, 8, 16 and 32 ms, set in configuration word 3.
Input 15 can act as a counter input with fast/raw or filtered data selectable.
Counter functions are unavailable with 1794-ASB or ASB2 adapters, a documented limitation.
30 mA Flexbus current and 5.7 W dissipation are the module's own overhead.
PNP sensors and sourcing output devices feeding a FLEX I/O island.
Panels standardised on sourcing field devices, where a sinking card would need rewiring.
Not a sink/source universal card; the wiring polarity is fixed.
Not for 48V or 125V DC; other cards cover those ranges.
<Sourcing sensor islands.
Machines with European-style PNP wiring.
Not for extended temperature; -20...55 deg C, with a derating curve for the supply.
Not the 32-point density; the 1794-IV32 doubles it on a TB32 base.
What is the difference between the 1794-IV16 and 1794-IB16?
The IV16 is sourcing and the IB16 is sinking; the wiring polarity differs.
What voltage range applies?
10...31.2V DC, 24V DC nominal.
What is the on-state current?
8.0 mA at 24V DC, up to 11 mA.
What filter times are available?
0.25 to 32 ms in eight steps, 0.25 ms default.
What is the isolation rating?
Type tested at 2121V DC for 1 s between user and system.
What is the operating temperature?
-20...55 deg C.
1794-IV16 is a digital DC input with 16 inputs in the FLEX I/O range, rated for 48V DC, sourcing. It mounts on the 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK terminal base unit, which is ordered separately and is the part that actually carries the field terminals.
| Attribute | Value |
| Catalog number | 1794-IV16 |
| Module type | digital DC input |
| Points | 16 inputs |
| Electrical range | 48V DC, sourcing |
| Terminal base unit | 1794-TB3, 1794-TB3S, 1794-TB3K, 1794-TB3SK |
| On-state input | 10V DC minimum, 48V DC nominal, 60V DC maximum, sourcing |
| Off-state input | 10V DC maximum |
| On-state current | 4.1 mA nominal at 24V DC, 11 mA maximum |
| Off-state current | 4.1 mA maximum |
| Input impedance | 4.7 kOhm maximum |
| Power dissipation | 5.7 W at 31.2V DC |
| Operating temperature | -20 to +55 C |
FLEX I/O is a backplane-free architecture: the terminal base unit snaps onto the DIN rail to the right of the adapter and the bases plug together to form the backplane. The module then sits on top of the base, so the base is chosen for the field wiring and the module for the signal, and the two are ordered separately.
Temperature class is written per module and per base, and the lower of the two governs the slice. A 70 C base carrying a 55 C module is a 55 C slice, which is why the extended temperature modules exist as a matched set rather than as an upgrade to one part of the pair.
One point about the 24V DC digital slices that catches panel builders: the adapter supplies the field power for the modules on its own 24V output, and that output is current limited. On a 1794-ADN the supply output is 450 mA at 24V, so a slice of 16 point DC modules can exhaust the adapter before the cabinet is half filled, and a separate field supply has to be introduced rather than assumed.
Mounting is a DIN rail operation on both parts and the order of assembly is base first, module second: the base slides onto the rail, its backplane fingers engage the neighbouring base, and the module is then pressed onto the base and secured. Removing a module does not break the backplane, which is why a failed slice can be swapped without rewiring the row.
The 22 to 12 AWG acceptance range on the standard bases is wider than the field device terminals in most panels, so the practical constraint is usually the device end, not the base end. Where a 24V DC sensor cable is 18 AWG and the base accepts 12 AWG, the conductor still has to be torqued to the published value rather than to feel.
Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.
The Allen-Bradley Flex I/O 1794 modules category groups the other catalog numbers, options and spare parts in the same range.