Product Details:
Payment & Shipping Terms:
|
The 1794-IP4 puts four independent counters in one FLEX I/O slot at 100 kHz, with 6V on-state and 3V off-state thresholds and overflow detection referenced to the internal clock.
Four channels is the practical difference from the two-channel cards: four meters, four shafts or four production lines counted from one base.
| 1794-IJ2 | 2-channel frequency input module, 1...32 kHz | IN STOCK |
| 1794-IJ2XT | 2-channel frequency input module, extended temperature | IN STOCK |
| 1794-VHSC | 2-axis very high speed counter, 1 MHz, 8 compare windows | IN STOCK |
| 1794-ID2 | 2-channel counter with A, B, Z and gate inputs | IN STOCK |
| 1794-IP4 | 4-channel counter module, 100 kHz | IN STOCK |
Application |
FLEX I/O counter, 1794 terminal base |
Cat Num |
1794-IP4 |
Brand Name |
Rockwell |
Channels |
4 counter channels |
Frequency |
100 kHz |
Input thresholds |
6V on-state, 3V off-state |
Sensor current |
3, 9 and 15 mA |
Overflow detection |
65 ms at the 1 MHz clock, 6.5 ms at 10 MHz |
Operating temperature |
0...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Four counter channels at 100 kHz in a single slot, which is twice the channel count of the 1794-ID2.
6V on-state and 3V off-state thresholds define the sensor interface; a 5V encoder output is marginal against a 6V threshold and a 24V sensor needs an interface.
Sensor current of 3, 9 and 15 mA at the corresponding supply levels is the published drive capability.
Overflow is detected at 65 ms with the 1 MHz clock and 6.5 ms with the 10 MHz clock, which is how a counter that wraps is reported rather than silently lost.
100 kHz is the ceiling on every channel, so four fast inputs do not share a bandwidth pool.
The overflow window is the number to check against the process: a count that can wrap inside 65 ms needs a wider preset, not a faster card.
0...55 deg C operating range places the card in a heated enclosure.
Thresholds at 6V on and 3V off give 3V of hysteresis, which is what keeps a noisy signal from double-counting.
Check the sensor's guaranteed output at the lowest supply voltage, not at nominal 24V; that is where a marginal 5V encoder drops under the 6V threshold.
One terminal base serves four counters, so the field wiring is denser than on the two-channel cards and the schedule is drawn before installation.
Shielded twisted pair per channel with the shield at the panel, and the pairs kept apart from drive feeders.
Verify each channel with a known pulse source before the line runs, because a threshold problem looks like a count problem.
Field power removed before insertion, as with every module on a 1794 base.
Four independent counters on one island — meters, shafts or line totals.
Simple totalising without quadrature or compare windows.
Not for quadrature position; the 1794-VHSC decodes A, B and Z at up to 1 MHz.
Not for sine wave pickups; the 1794-IJ2 accepts 1...32 kHz analogue input with wire-off detection.
1794-IP4: four channels, 100 kHz, 6V/3V thresholds, overflow detection, no gate or index inputs published.
1794-ID2: two channels with A, B, Z and gate inputs and a 304.8 m cable allowance.
1794-VHSC: two axes to 1 MHz with eight compare windows and two outputs.
1794-IJ2: two frequency channels for 1...32 kHz pickups with two isolated outputs.
How many counters has the 1794-IP4?
Four independent counter channels.
What is the maximum count rate?
100 kHz on each channel.
What are the input thresholds?
6V on-state and 3V off-state, with 3, 9 or 15 mA sensor current.
How is overflow reported?
Detected within 65 ms at the 1 MHz clock or 6.5 ms at 10 MHz.
What is the operating temperature?
0...55 deg C.
How does it differ from the 1794-ID2?
Four channels instead of two, without the A, B, Z and gate inputs of the ID2.
1794-IP4 is a FLEX I/O specialty module for the 1794 system, documented here from the Rockwell specialty module technical data so that the input thresholds, the counting limits, the output ratings and the terminal base requirement are stated for this catalog number.
| Specification | Value |
|---|---|
| Catalog number | 1794-IP4, FLEX I/O 4 input pulse counter |
| Inputs | 4 inputs in 2 groups of 2 |
| Counting frequency | 100 kHz |
| Input pulse width | Each signal condition must be stable for at least 2 microseconds to be recognised |
| Supply voltage | 12 to 24V DC plus or minus 10 percent, 150 mA at 12V DC and 75 mA at 24V DC |
| On-state input | 26.4V DC maximum, 3 mA minimum at 6V DC, 9 mA nominal at 12V DC, 15 mA maximum at 24V DC |
| Off-state input | 3V DC maximum, minus 26.4V DC minimum |
| Flexbus current | 5 mA at 5V DC |
| Operating temperature | 0 to 55 degrees C |
| Source | 1794-TD017-EN-E FLEX I/O specialty modules |
Four inputs in two groups of two is the compact version of the same counter family: fewer channels, fewer terminals, and the same hundred kilohertz counting rate and two microsecond pulse width. It suits a machine that needs two quadrature signals and nothing else.
The twelve to twenty four volt field supply is separate from the flexbus, and the module asks for a hundred and fifty milliamps at twelve volts or seventy five at twenty four. That field supply belongs on the bill of materials next to the module, not on the rail supply calculation.
These modules are judged on four figures: the maximum rate or count, the minimum pulse width or processing time, the input threshold with its sensing current, and the output rating with its protection behaviour. The table carries all four, and the notes explain where each of them limits the machine rather than the module.
Isolated output groups are a safety and noise measure rather than an electrical feature. Two isolated groups of one or two outputs allow separate field supplies and separate returns, which is what a counter module needs when it drives a valve on one circuit and a lamp on another.
Wire off detection is the diagnostic that saves a commissioning day. A small detect current through a shunt resistor proves the field circuit is closed before the machine runs, and losing that function by wiring without the shunt is a silent trade.
Sensing threshold and sensing level are two different engineering questions. One asks whether a 5 volt or a 24 volt signal crosses the threshold reliably, the other asks how much current the front end draws and whether a two wire sensor can supply it, and both appear in the same table for that reason.
Short circuit protection that latches off until power is cycled is a behaviour a maintenance team has to know. It protects the module, and it also means a field short stops the output until someone opens the panel, which is a commissioning note rather than a datasheet footnote.
A counter module counts edges, so mechanical contact bounce becomes counts. Debounce is either a filter setting or a hardware answer, and a panel that uses a dry contact on a fast counter without either will report counts that do not exist.
Filter selections are the answer to electrical noise, and they cost resolution. Off, ten microseconds, a hundred microseconds, a millisecond and ten milliseconds per channel group is a menu, and choosing a heavy filter to clean up a noisy encoder also caps the maximum frequency the channel can count.
Compare windows turn a counter into a cam controller. Eight windows tied to two physical outputs is a small motion controller built from a counter module, and the resolution of the windows is the resolution of the machine, not the resolution of the counter.
These modules draw only a few milliamps from the flexbus, and their field supplies are separate. A rail budget that charges them like discrete outputs will over provision the adapter, while a rail that forgets the field supply will find the module dead but the indicators healthy.
The maximum count value is a range statement, not a memory statement. A twenty four bit counter wraps at over sixteen million counts, and a machine that counts a fast pulse train for a week has to know exactly when that wrap happens and how the program handles it.
A frequency input module with gate channels measures direction as well as rate. The gate input establishes direction while the frequency input provides the pulse train, and that pairing is what allows a flow meter or an encoder to report signed rate rather than speed alone.
A specialty module in a FLEX rail exists because the adapter cannot time an event. A scan based discrete module takes a snapshot, and a counter or frequency module does its own arithmetic between scans, which is why these parts carry processing time and pulse width limits instead of turn on delays.
Pulse width is the real bandwidth limit. A minimum pulse of a few microseconds defines how fast an input can toggle regardless of the nominal frequency, and an encoder with a fine line count at high speed will violate that before it violates the frequency rating.
Accuracy and resolution are quoted separately for a reason. A resolution of a hundredth of a percent with an accuracy of a few tenths of a percent means the display can show digits that the measurement does not justify, and a control loop tuned to those digits will chase noise.
Use it where two counting groups are enough, keep the field supply on the drawing, and verify the two microsecond pulse width against whichever sensor feeds it.
The Allen-Bradley Flex I/O 1794 modules category lists the related catalog numbers, options and accessories for this range.