Product Details:
Payment & Shipping Terms:
|
The 1794-IF8IH is the isolated HART analog input: eight channels, each with its own reference and its own HART device, 16-bit resolution and six selectable conversion rates from 4.17 to 470 Hz.
Isolation plus HART is the combination that suits a plant with smart transmitters on separate grounds: the digital diagnostics arrive in the controller and no ground loop reaches the FlexBus.
| 1794-IE8 | 8-channel analog input module | IN STOCK |
| 1794-IE8XT | 8-channel analog input module, extended temperature | IN STOCK |
| 1794-IE8H | 8-channel HART analog input module | IN STOCK |
| 1794-IE12 | 12-channel analog input module | IN STOCK |
| 1794-IE12K | 12-channel analog input module, conformal coated | IN STOCK |
| 1794-IF4I | 4-channel isolated analog input module | IN STOCK |
| 1794-IF4IXT | 4-channel isolated analog input, extended temperature | IN STOCK |
| 1794-IF4ICFXT | 4-channel isolated analog input, conformal coated | IN STOCK |
| 1794-IF8IH | 8-channel HART isolated analog input module | IN STOCK |
| 1794-IR8 | 8-channel RTD input module | IN STOCK |
| 1794-IRT8 | 8-channel thermocouple/RTD input module | IN STOCK |
| 1794-IRT8XT | 8-channel thermocouple/RTD input, extended temperature | IN STOCK |
| 1794-IT8 | 8-channel thermocouple/mV input module | IN STOCK |
| 1794-IE8XOE4 | 8-input, 4-output analog combination module | IN STOCK |
| 1794-IE4XOE2 | 4-input, 2-output analog combination module | IN STOCK |
| 1794-IF2XOF2I | 2-input, 2-output isolated analog combination module | IN STOCK |
| 1794-OE4 | 4-channel analog output module | IN STOCK |
| 1794-OE12 | 12-channel analog output module | IN STOCK |
Application |
FLEX I/O HART isolated analog input, 1794 terminal base |
Cat Num |
1794-IF8IH |
Brand Name |
Rockwell |
Channels |
8, isolated channel to channel, one HART device per channel |
Input ranges |
4...20 mA, 0...20 mA (default 0...20 mA) |
Resolution |
16 bits unipolar, 15 bits plus sign bipolar; 0.320/0.640 uA per count |
Input resistance |
249 Ohm +/-1% |
Conversion rates |
4.17, 10.0, 16.7, 19.6, 62 and 470 Hz |
Step response |
480 ms to 4 ms depending on conversion rate |
Accuracy |
0.1% of full scale at 25 deg C |
Isolation |
120V continuous basic insulation; 1000V AC for 60 s channel to channel |
External supply current |
190 mA at 24V DC |
Power dissipation |
4.8 W at 31.2V DC (6.8 BTU/hr) |
Operating temperature |
0...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Channel-to-channel isolation at 120V continuous,type tested at 1000V AC for 60 s, is what separates this card from the non-isolated HART module.
One HART device per channel on a 4...20 mA or 0...20 mA loop, with the default range 0...20 mA until configured.
249 Ohm +/-1% input resistance is the HART loop burden, and the 1% tolerance is tight enough that eight channels read the same loop the same way.
32 mA DC continuous overload on any or all channels covers the miswiring and fault cases that a loop sees in service.
Isolation is stated between user power and system, channel and system, and channel and channel,which is the full three-way statement rather than a single figure.
Six rates: 4.17, 10.0, 16.7, 19.6, 62 and 470 Hz — the two low rates are tied to 50 and 60 Hz line rejection.
Step response goes from 480 ms at 4.17 Hz to 4 ms at 470 Hz,so a fast pressure loop and a slow tank level can share a card if the channels are configured separately.
Normal mode rejection above 70 dB at 50/60 Hz at 4.17 Hz and above 85 dB at 60 Hz at 19.6 Hz is the published table.
Sigma-delta conversion is the reason the low rates reject so well; the high rate is for speed, not for a noisy environment.
Accuracy is 0.1% of full scale at 25 deg C across all rates, unchanged by the filter choice.
190 mA at 24V DC is the module consumption, the same as the non-isolated HART card.
4.8 W at 31.2V DC (6.8 BTU/hr) is higher than the 3.9 W of the non-isolated HART card, and the enclosure calculation has to use this larger figure.
0...55 deg C operating range is narrower than the -20 deg C start of the standard analog cards.
The card does not power the loop;a two-wire transmitter needs its 24V supply and sees 249 Ohm as its burden.
Per-channel isolation means each loop can keep its own return, which is the practical answer to mixed grounded transmitters.
Shielded twisted pair per loop remains good practice; HART signalling shares the pair with the 4...20 mA value and both are low level.
One device per channel, no multidrop on a single input, which is the published configuration limit.
Configuration changes can be made in RUN mode,so a transmitter range change does not require a download stop.
Smart transmitters on separate grounds where both HART and isolation are required.
Mixed-speed loops on one card — a 470 Hz pressure channel beside a 4.17 Hz level channel.
Not for thermocouples.HART is a current-loop protocol; temperature inputs need the 1794-IRT8.
Cost against the 1794-IE8H:the non-isolated HART card is cheaper and runs cooler; choose this one only when the isolation is genuinely needed.
How many channels has the 1794-IF8IH?
Eight isolated HART channels, one field device per channel.
What isolation does it provide?
120V continuous basic insulation, type tested at 1000V AC for 60 s channel to channel, channel to system and user power to system.
What conversion rates are available?
4.17, 10.0, 16.7, 19.6, 62 and 470 Hz, with step responses from 480 ms to 4 ms.
What is the input burden?
249 Ohm +/-1% on a 4...20 mA or 0...20 mA loop.
How accurate is it?
0.1% of full scale at 25 deg C.
What temperature range applies?
0...55 deg C operating.
This part sits in the Allen-Bradley Flex I/O 1794 modules category, with the other models and spare parts listed alongside it.