The 1794-OB16 is the sixteen-point 24V DC sourcing output module: 500 mA on every channel, 8 A for the module, and the same terminal base family as the input cards.
It is the default output card of a FLEX I/O island — sixteen valve coils, starter coils or lamps on one slot, with the field supply landed on row C of the base.
| 1794-OB8 | 8-point 24V DC sourcing output module | IN STOCK |
| 1794-OB8EP | 8-point 2 A electronically fused sourcing output module | IN STOCK |
| 1794-OB16 | 16-point 24V DC sourcing output module | IN STOCK |
| 1794-OB16P | 16-point protected sourcing output module | IN STOCK |
| 1794-OB16D | 16-point diagnostic 24V DC output module | IN STOCK |
| 1794-OB32P | 32-point protected sourcing output module | IN STOCK |
| 1794-OB16PXT | 16-point protected sourcing output, extended temperature | IN STOCK |
| 1794-OB8EPXT | 8-point 2 A electronically fused output, extended temperature | IN STOCK |
| 1794-OV16 | 16-point sinking output module | IN STOCK |
| 1794-OV16P | 16-point protected sinking output module | IN STOCK |
| 1794-OV32 | 32-point sinking output module | IN STOCK |
| 1794-OC16 | 16-point 48V DC sourcing output module | IN STOCK |
| 1794-OG16 | 16-point 5V DC sourcing output module | IN STOCK |
| 1794-OW8 | 8-point isolated relay output module | IN STOCK |
Application |
FLEX I/O digital output, 1794 terminal base |
Cat Num |
1794-OB16 |
Brand Name |
Rockwell |
Outputs |
16, current, sourcing |
On-state voltage |
10V DC min, 24V DC nom, 31.2V DC max |
Output current |
500 mA per channel, 8 A per module |
On-state voltage drop |
0.5V DC max |
Off-state leakage |
0.5 mA max |
Surge current |
2 A for 50 ms, repeatable every 2 s |
Output delay |
0.5 ms off to on, 1.0 ms on to off |
External supply current |
20...65 mA |
Isolation |
50V continuous; tested 850V DC for 1 s, I/O to system |
Power dissipation |
5.3 W max at 31.2V DC (18.1 BTU/hr) |
Terminal base |
1794-TB2, -TB3, -TB3S, -TB3K, -TB3SK |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
500 mA per channel, 8 A per module across 10...31.2V DC, 1.0 mA minimum load and 0.5 mA maximum off-state leakage.
0.5V DC maximum drop keeps the coil voltage close to the supply, which matters on a 24V solenoid rated at 90% pick-up.
2 A surge for 50 ms every 2 s lets the module drive a lamp or a small brake without an interposing relay.
8 A for the module is the sum of sixteen channels at 500 mA; using every channel at rating leaves no margin for an inductive inrush.
When one 24V rail feeds both halves of the island, the 5% ripple figure has to hold at the panel terminals, not at the supply output.
Without diagnostics a failed channel looks exactly like a channel that was never commanded; a current clamp at the terminal separates the two.
The terminal base carries both the logic connection and the field terminals, so a module change does not disturb the wiring.
Sixteen outputs on one slot is the whole point: two 1794-OB8 modules cost an extra base and an extra length of rail.
20...65 mA from the field supply is the module's own consumption, separate from load current, and it rises with the number of energised channels.
10...31.2V DC with 5% ripple — the same range as the input modules, so one field supply can serve both halves of an island.
5.3 W maximum dissipation (18.1 BTU/hr) at 31.2V DC, on a 94 x 94 x 69 mm footprint including the base.
Not fused internally. Rockwell specifies a SAN-O M04-800 mA fuse per output; a fused 1794-TBNF base keeps it at the terminals.
No per-channel diagnostics. A failed output reads as a logic state, not as a fault — the diagnostic version of this function is the 1794-OB16D.
<For self-protection, the 1794-OB16P shuts the channel down on short or overload and recovers when the fault clears, without reporting it.
0.5 ms off to on, 1.0 ms on to off. Both figures are maxima and independent of load within the rated current.
50V continuous basic insulation, tested at 850V DC for 1 s, field side to system, with no isolation between channels.
One common return for sixteen outputs means a field wiring fault can take out several channels at once — a wiring discipline question, not a module limitation.
Sixteen outputs on one base halves the slot count against two 1794-OB8 modules, and the base is shared with the 16-point input cards.
For 32 points the 1794-OB32P with two 16-channel groups is the equivalent step, on the TB32 base.
For loads above 500 mA the 1794-OB8EP at 2 A per channel is the only FLEX I/O option in this range.
What is the output rating of the 1794-OB16?
500 mA per channel and 8 A per module, sourcing, over 10...31.2V DC.
How many outputs does it have?
Sixteen, all sourcing, on one terminal base.
Is it protected against short circuits?
No internal protection and no internal fusing; Rockwell specifies an external SAN-O M04-800 mA fuse. The 1794-OB16P is the self-protected version.
What is the module's own supply current?
20...65 mA from the external 10...31.2V DC field supply.
Which terminal bases fit?
1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3K and 1794-TB3SK.
Does it report faults to the processor?
No. Fault reporting is the 1794-OB16D diagnostic module.