Product Details:
Payment & Shipping Terms:
|
The 1794-OA8K is the coated build of the eight-point 120V AC output: same triac stage, same 4 A module ceiling, with the board protected for condensing and corrosive cabinets.
Panels that specify a coated bill of materials usually pair it with a coated terminal base, because the coating has to cover the base as well as the module to be worth anything.
| 1794-IA8 | 8-point 120V AC input module | IN STOCK |
| 1794-IA8I | 8-point 120V AC input module, 1240V isolation | IN STOCK |
| 1794-IA16 | 16-point 120V AC input module | IN STOCK |
| 1794-IA16K | 16-point 120V AC input module, conformal coated | IN STOCK |
| 1794-IM8 | 8-point 240V AC input module | IN STOCK |
| 1794-IM16 | 16-point 240V AC input module | IN STOCK |
| 1794-OA8 | 8-point 120V AC output module | IN STOCK |
| 1794-OA8I | 8-point 120V AC isolated output module | IN STOCK |
| 1794-OA8K | 8-point 120V AC output module, conformal coated | IN STOCK |
| 1794-OA16 | 16-point 220V AC output module | IN STOCK |
| 1794-OA16K | 16-point 220V AC output module, conformal coated | IN STOCK |
| 1794-OM8 | 8-point 240V AC output module | IN STOCK |
| 1794-OM16 | 16-point 240V AC output module | IN STOCK |
Application |
FLEX I/O digital output, coated build |
Cat Num |
1794-OA8K |
Brand Name |
Rockwell |
Outputs |
8, AC, triac |
Load voltage |
85V AC minimum, 132V AC maximum |
Output current |
500 mA per channel at 55 deg C, 750 mA at 35 deg C |
Module current |
4.0 A maximum |
Off-state leakage |
2.25 mA maximum |
Isolation |
2150V DC for 1 s; 1250V AC for 60 s |
Coating |
Conformal coated (K catalog variant) |
Operating temperature |
-20...55 deg C |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Conformal coating on the module assembly, the K suffix convention across FLEX I/O.
Electrical behaviour unchanged: 85...132V AC load window, 500 mA per channel at 55 deg C.
The same 2.25 mA off-state leakage, so bleeder resistors are still the fix for a coil that will not drop out.
-20...55 deg C operating, the standard AC output range.
4.0 A module total against 8 x 500 mA of channel rating: the two figures cannot both be met at once.
<7 A surge for 45 ms every 8 s covers filament inrush and small AC coils.
Inductive loads need a suppression network at the coil; a triac without one sees the kick every half cycle.
Transformer primaries should go to a relay output instead.
1.6 A 250V slow-blow per output, Littelfuse 23901.6 or SAN-O SD6-1.6A.
5 mA minimum load for the triac to latch reliably.
1.0V on-state drop at 0.5 A, about 4 percent of a 120V supply.
2150V DC for 1 s isolation between field and logic.
Coated AC output islands on 120V loads.
Solenoid panels in humid or coastal plants.
Not a 220V output; the OA16 family covers the higher voltage range.
Not a relay output; leakage and minimum load both apply.
OA8 and OA8K publish the same electrical table, so the choice is environmental, not functional.
Base pairing matters: a coated module on an uncoated base leaves the terminals exposed.
Not extended temperature; 55 deg C is the ceiling.
Not for DC loads.
What does the K suffix mean on the 1794-OA8K?
A conformally coated module assembly.
What is the output rating?
500 mA per channel at 55 deg C, 750 mA at 35 deg C, 4.0 A for the module.
What load voltage does it switch?
85...132V AC.
What is the off-state leakage?
2.25 mA maximum.
What fuse is specified?
1.6 A 250V slow-blow, Littelfuse 23901.6 or SAN-O SD6-1.6A.
What is the operating temperature?
-20...55 deg C.