Allen Bradley PLC 1794-TB3GS / 1794TB3GS

China Allen Bradley PLC 1794-TB3GS / 1794TB3GS supplier
Allen Bradley PLC 1794-TB3GS / 1794TB3GS supplier Allen Bradley PLC 1794-TB3GS / 1794TB3GS supplier Allen Bradley PLC 1794-TB3GS / 1794TB3GS supplier Allen Bradley PLC 1794-TB3GS / 1794TB3GS supplier Allen Bradley PLC 1794-TB3GS / 1794TB3GS supplier Allen Bradley PLC 1794-TB3GS / 1794TB3GS supplier Allen Bradley PLC 1794-TB3GS / 1794TB3GS supplier Allen Bradley PLC 1794-TB3GS / 1794TB3GS supplier Allen Bradley PLC 1794-TB3GS / 1794TB3GS supplier

Large Image :  Allen Bradley PLC 1794-TB3GS / 1794TB3GS

Product Details:

Place of Origin: Made in MALAYSIA
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1794-TB3GS / 1794TB3GS

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $88.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 10 PCS
Detailed Product Description

1794-TB3GS technical data PDF download FLEX I/O 1794-TB3GS / 1794TB3GS Grounded Spring Clamp Base

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC I/O

The 1794-TB3GS is the spring clamp version of the grounded base: 36 I/O, 2 common, 2 +V and 10 chassis ground terminals.

Ten grounding terminals are what an analog module needs — one per channel pair for a shield, rather than a shared return that lets channel noise couple.

1794-TB2 16-terminal cage clamp base, 2-wire, up to 132V AC IN STOCK
1794-TB3 16-terminal cage clamp base, 3-wire devices IN STOCK
1794-TB3S 16-terminal spring clamp base, 3-wire devices IN STOCK
1794-TB32 32-terminal cage clamp base for 32-point modules IN STOCK
1794-TB32S 32-terminal spring clamp base for 32-point modules IN STOCK
1794-TB3T temperature base with two cold junction compensation sets IN STOCK
1794-TB3TS spring clamp temperature base with CJC sets IN STOCK
1794-TB3G grounded screw clamp base, 36 I/O, 10 chassis ground IN STOCK
1794-TB3GS grounded spring clamp base, 36 I/O, 10 chassis ground IN STOCK
1794-TBKD cage clamp base with 16 knife disconnects IN STOCK
1794-TBN NEMA-style screw clamp base, up to 264V AC/DC IN STOCK
1794-TBNF fused NEMA-style base, eight 5 x 20 mm fuses IN STOCK
1794-TB37DS 37-pin D-shell termination for digital and analog modules IN STOCK
1794-TB62DS 62-pin D-shell termination for digital and analog modules IN STOCK

Product Specifications 1794-TB3GS (PDF)
 Application
 FLEX I/O grounded terminal base for analog modules
 Cat Num
 1794-TB3GS
 Brand Name
 Rockwell
 Termination
 Grounded spring clamp, 36 I/O, 2 common, 2 +V, 10 chassis ground
 Wire size
 0.34...3.3 mm2 (22...12 AWG), 75 deg C or greater
 Current capacity
 10 A maximum
 Wiring category
 2
 Dimensions
 94 x 94 x 69 mm
 Operating temperature
 -20...70 deg C

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1794-DU001 (module specifications) and 1794-SG002 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1794-TB3GS original product photograph, wide view 1794-TB3GS original product photograph, wide view 1794-TB3GS original product photograph, wide view

Terminals

36 I/O terminals, 2 common, 2 +V and 10 chassis ground, the pattern the guide assigns to grounded analog bases.

Spring clamp termination with 22...12 AWG wire and a 10 A rating.

Two common and two +V terminals only, so this base is not a 3-wire digital base despite the terminal count.

94 x 94 x 69 mm footprint, -20...70 deg C.

Grounding

Individual grounding per channel pair is the reason the base exists; analog shields land close to their own signal.

The rail itself must be zinc-plated, yellow-chromated steel for the chassis path to work.

Aluminium or plastic rail breaks that path, causing intermittent grounding the guide warns about.

Panel mount uses star-washer screws through the base mounting holes when no rail is available.

Application

Analog input and output modules with shielded field wiring.

Noise-sensitive loops — 4...20 mA transmitters, load cells, thermocouples on the IR8.

Not a digital base; 2 common and 2 +V will not wire 16 discrete points comfortably.

Not the temperature base; CJC sets live on the 1794-TB3TS.

Mounting

35 x 7.5 mm DIN rail with 25 mm air space around the system.

1794-NM1 panel kit and 1492-EA35 rail locks where appropriate.

Bases plug together to form the backplane with one end cap per system.

Vertical mounting is permitted on the standard rail.

Where it fits

Analog islands with shielded cable, spring terminated.

Panels that standardise on spring clamps across the whole rail.

Not for discrete I/O; the 1794-TB32S carries 32 points with 8 common.

Not the coated version; the 1794-TB3GSK adds the K coating.

FAQ — 1794-TB3GS

How many chassis ground terminals has the 1794-TB3GS?

10, for individual grounding of analog channels.

Is it spring or screw termination?

Spring clamp, the spring version of the 1794-TB3G.

How many I/O terminals does it have?

36 I/O, with 2 common and 2 +V.

What is the current capacity?

10 A maximum.

What rail does the grounding require?

Zinc-plated, yellow-chromated steel DIN rail, 35 x 7.5 mm.

What is the operating temperature?

-20...70 deg C.


Data sources. Technical values on this page come from Rockwell publication 1794-SG002 (FLEX I/O Selection Guide, terminal base comparison) and 1794-IN092. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

Where the 1794-TB3GS sits in the FLEX I/O range

1794-TB3GS is a FLEX I/O terminal base unit, not an I/O module. It is the part that carries the field terminals, plugs into the adjacent base to form the backplane, and holds the module on top. The termination type here is Grounded spring clamp with 36 I/O, 2 common, 2 +V, 10 chassis ground.

AttributeValue
Catalog number1794-TB3GS
Termination typeGrounded spring clamp
Connections36 I/O, 2 common, 2 +V, 10 chassis ground
Current capacity, maximummodule dependent
Wiring category2
Field voltagePer module
Operating temperature-20...+70 C
Purpose in the rangeA spring clamp version of the 1794-TB3G.

The conductor range for this base is 0.34 to 3.3 mm2 (22 to 12 AWG) solid or stranded copper rated 75 C or greater, with 1.2 mm maximum insulation, with a maximum current capacity of module dependent across the base. Those figures are the base rating and not the module rating: a 16 point module on a 10 A base is still limited by the module output current per channel.

Selecting a base is a compatibility step, not a preference step. The module data sheet names the bases that are permitted for it, and a base outside that list may key differently, may not carry the required common and voltage terminals, or may not be rated for the field voltage of the module.

Conformal coated variants carry a K suffix and exist because the same base can be asked to survive washdown, condensate, or corrosive atmosphere. Ordering the uncoated base and treating it in the field is not equivalent and does not carry the same published rating.

FLEX I/O bases and modules are separate line items on a purchase order, and the price of getting that wrong is a second shipment: a module without its base cannot be installed, and a base of the wrong termination type cannot be reworked in the field because the module keys to the base family.

For a retrofit into an existing slice, the addressing is decided by position rather than by catalog number: FLEX I/O assigns the module its place in the rack by the order of the bases on the rail, so inserting a module in the middle shifts the addresses of everything to its right and requires the program to be re-checked.

On the 32 point bases the common and voltage terminals are grouped in eight pairs rather than eighteen, which is why the 32 point digital modules can mix sinking and sourcing groups in one slice and why the terminal numbering on the drawing does not follow the 16 point pattern.

Any FLEX I/O position is a pair on the purchase order: one base, one module. Stocking modules without bases, or bases without the matching modules, produces a slice that cannot be commissioned, and the two part numbers are never interchangeable across the 8, 16 and 32 point families.

Practical check before ordering: confirm the permitted terminal base for the module, confirm the conductor range and current capacity of that base against the field wiring schedule, confirm whether the location needs the conformal coated K variant, and confirm the operating temperature class against the panel interior rather than the room.

Related models, options and spare parts for this range are listed in the Allen-Bradley Flex I/O 1794 modules category.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)