logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IT6I / 1756IT6I

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IT6I / 1756IT6I

China Allen Bradley PLC 1756-IT6I / 1756IT6I supplier
Allen Bradley PLC 1756-IT6I / 1756IT6I supplier Allen Bradley PLC 1756-IT6I / 1756IT6I supplier Allen Bradley PLC 1756-IT6I / 1756IT6I supplier Allen Bradley PLC 1756-IT6I / 1756IT6I supplier Allen Bradley PLC 1756-IT6I / 1756IT6I supplier Allen Bradley PLC 1756-IT6I / 1756IT6I supplier

Large Image :  Allen Bradley PLC 1756-IT6I / 1756IT6I

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IT6I / 1756IT6I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $1438.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IT6I technical data PDF download 1756-IT6I ControlLogix 6 Point Thermocouple Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IT6I (also written 1756IT6I) is the six-channel thermocouple input of the first isolated analog generation: six channels with two millivolt ranges, -12...78 mV for full thermocouple spans and -12...30 mV for the high-resolution range, backplane load 200 mA at 5.1 V DC and 150 mA at 24 V DC, total backplane power 4.6 W (1756-TD002).

The two ranges decide the usable span per thermocouple type, and the published table makes that explicit: a type K covers -270...1372 °C on the 78 mV range but only -270...725 °C on the 30 mV range, and a type B is full range on both because its output rises late in the span. Choosing the narrow range for resolution can therefore cost most of the measurement range.

Resolution is quoted per type: approximately 0.05 °C for E, J, K, T and N on the wide range and 0.03 °C on the narrow range, 0.15 °C for B, R, S and C, 0.07 °C for D and 0.02 °C for L (TXK/XK). Calibrated accuracy is 0.05 % of full range typical and better than 0.1 % worst case, with a 12-month calibration interval.

Cold junction compensation uses the sensor shipped with the module, part number 94238301, replaceable as RP-94238301 — one sensor for the module, not one per channel. Technical data 1756-TD002, user manual 1756-UM009.

1756-IF4FXOF2F
4 high-speed differential inputs + 2 outputs, 375 mA, reinforced isolation
In stock
1756-IF6CIS
6 isolated current inputs with sourcing 24 V DC loop supply
In stock
1756-IF6I
6 isolated inputs, 16-bit, 250 mA, channel-to-channel basic isolation
In stock
1756-IF8
8 single-ended / 4 differential inputs, 200 mA, 250 V basic to backplane
In stock
1756-IF8H
8 differential HART current inputs, A and B series
In stock
1756-IF16
16 single-ended / 8 differential inputs, 200 mA, 15 Hz bandwidth
In stock
1756-IF16H
16 differential HART current inputs, A and B series
In stock
1756-IRT8I
8 isolated RTD and thermocouple inputs, 24-bit, 1756-CJC required
In stock
1756-IR6I
6 isolated RTD inputs, 20-pin block, discontinued 2017
In stock
1756-IT6I
6 thermocouple inputs, two mV ranges, one CJC sensor
In stock
1756-IT6I2
6 isolated thermocouple inputs, 16-bit, two CJC sensors
In stock

 Application
 Analog input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IT6I
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 6
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Analog Input Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN063 (analog I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IT6I thermocouple input product photograph 1756-IT6I terminal side product photograph 1756-IT6I module view product photograph

Where the module sits in a typical system

The IT6I is a legacy-support module now: six thermocouples in panels built before the 1756-IRT8I and 1756-IT16 generations, where the field wiring and the terminal block are already in place.

Where the module is still specified by an existing drawing, the two-range arrangement is its advantage: mixed type K and type B on one module, each channel set to the range that gives usable resolution over its span.

For new work the IT16 provides 16 channels and the IRT8I provides 8 isolated channels accepting both thermocouples and RTDs, with 24-bit resolution.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's analogue I/O instructions include keying as a step, and a block keyed for a different module will not seat.
  2. Wire signal conductors to category 2 and keep them out of the same duct as the 480 V motor feeders. The analogue front end is the part of the rack that reads induced noise as measurement.
  3. Terminate the cable shield at the panel earth, not at the module terminals. A shield carried onto the RTB becomes an antenna for the next drive cabinet.
  4. Set the notch filter to the local mains frequency — 50 Hz or 60 Hz — in the Logix Designer project. The published settling time, scan time and noise rejection figures are all quoted at a selected notch frequency.
  5. Check the field range against the module's real range, not the sensor's nominal one. An IF6I accepts 0...21 mA with overrange indication, which is wider than a 4...20 mA transmitter needs and narrower than a 0...25 mA device supplies.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  One CJC for six channels  The 94238301 sensor serves the module. A thermocouple landed on a channel whose CJC is far away in temperature measures a gradient, not the process.
 Check 3  Input impedance above 10 MΩ  High enough that a thermocouple's loop resistance does not load the junction; the limit that matters is the 120 V AC/DC overvoltage rating.
 Check 4  250 V basic, channel to channel  Per-channel isolation on the 6-channel family, at a basic rating. Reinforced barriers are on the newer 1756-IRT8I and 1756-IT16.
 Check 5  Open circuit detected within 2 s  A broken thermocouple reads positive full scale within 2 seconds — a diagnostic the project should be configured to alarm on.

Specifications per Rockwell publication 1756-TD002 (ControlLogix I/O Modules Specifications); module behaviour per 1756-UM009 and 1756-IN050.

Replacing a 1756-IF6I of an earlier generation

For 16 thermocouple channels, 1756-IT16 carries the wider count in one slot.

The 1756-IRT8I accepts thermocouples and RTDs on 8 isolated channels at 24-bit resolution, with the 1756-CJC as its cold junction sensor.

For RTDs rather than thermocouples, 1756-IR12 provides 12 channels at 24-bit; the 6-channel predecessor is 1756-IR6I.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IF4FXOF2F — 4 high-speed differential inputs plus 2 high-speed outputs in one slot, 375 mA at 5.1 V DC, 250 V reinforced isolation.
  • 1756-IF8 — 8 single-ended (or 4 differential) inputs, 200 mA at 5.1 V DC, 250 V basic isolation to the backplane.
  • 1756-IF16 — 16 single-ended inputs, 200 mA at 5.1 V DC, same ranges as the IF8 with 15 Hz channel bandwidth.
  • 1756-IF6I — 6 individually isolated inputs, 250 mA at 5.1 V DC, 16-bit resolution, channel-to-channel isolation.
  • 1756-IF6CIS — 6 isolated current inputs with per-channel 24 V DC loop sourcing for 2-wire transmitters.
  • 1756-IF8H / 1756-IF16H — the HART variants, 8 or 16 differential current inputs, one modem per module (A series) or per channel (B series).
  • 1756-IRT8I / 1756-IR12 — RTD and thermocouple measurement, 250 V reinforced isolation, 24-bit resolution.
  • 1756-TBNH / 1756-TBCH / 1756-TBSH / 1756-TBS6H — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IT6I ControlLogix 6 Point Thermocouple Input | Rockwell

What is the 1756-IT6I?

A 6-channel thermocouple input module with two millivolt ranges, -12...78 mV and -12...30 mV.

What is the backplane current?

200 mA at 5.1 V DC and 150 mA at 24 V DC, 4.6 W total backplane power (1756-TD002).

Why two ranges?

The narrow range gives higher resolution but a shorter usable span for most thermocouple types — type K reaches 1372 °C on the wide range and 725 °C on the narrow one.

How accurate is it?

0.05 % of full range typical, better than 0.1 % worst case, with a 12-month calibration interval.

Does it need a cold junction sensor?

Yes — one 94238301 sensor is shipped with the module and serves all six channels.

What isolation does it provide?

250 V continuous basic insulation, channel-to-channel and to the backplane.

Does it detect a broken thermocouple?

Yes — positive full scale reading within 2 seconds, which the project should be configured to alarm on.

What replaces it?

1756-IT16 for 16 channels, or 1756-IRT8I for 8 isolated channels accepting thermocouples and RTDs at 24-bit resolution.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IT6I. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)