logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE

China Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE supplier
Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE supplier Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE supplier Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE supplier Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE supplier Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE supplier Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE supplier

Large Image :  Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-IH16ISOE / 1756IH16ISOE

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $465.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-IH16ISOE technical data PDF download 1756-IH16ISOE Sequence of Events 90-140V DC Input | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-IH16ISOE (also written 1756IH16ISOE) is the sequence-of-events module for high-voltage DC circuits: 90...140 V DC, 1.15 mA at 90 V DC and 1.85 mA at 140 V DC, with a backplane load of 275 mA at 5.1 V DC and 2 mA at 24 V DC (1756-IN062).

Compared with the 1756-IH16I, the trade is visible in two figures. The ISOE accepts up to 140 V DC rather than 146 V, its input current is far lower — 1.15...1.85 mA against 1...3 mA — and its backplane draw is more than double, 275 mA against 125 mA. The sequence-of-events function is what the extra backplane current buys.

The lower input current matters on station-battery circuits: a 110 V DC trip circuit with a high-resistance path will still present enough current to register, and the module adds less burden than the non-ISOE variant.

Isolation is 250 V continuous basic from inputs to backplane and 250 V basic input-to-input — the same arrangement as the IH16I, so the two are interchangeable in a panel as far as isolation practice goes.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-IH16ISOE
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Input Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-IH16ISOE module product photograph 1756-IH16ISOE terminal side product photograph 1756-IH16ISOE module view product photograph

Where the module sits in a typical system

Sequence-of-events capture on 110 V DC circuits: trip and close sequences, breaker operations, and the order in which a station battery system's auxiliaries drop out. The time stamps make the event order defensible in a fault report.

Because the field burden is low, it suits circuits already loaded by other devices — a 110 V DC circuit driving coils and lamps has little current to spare, and 1.15 mA is easier to accommodate than 3 mA.

It is also the module for panels that mix 110 V DC signals with the rest of a ControlLogix rack, since the isolation practice matches the IH16I.

Commissioning in five steps

  1. Key the removable terminal block to the module before wiring. Rockwell's DC digital I/O instructions include keying as a step, and a wrongly keyed block will not seat.
  2. Wire to conductor category 1 and keep the field wiring separated from the analogue and communication classes in the panel (1770-4.1).
  3. Check the sinking or sourcing convention against the field device before terminating. The IB family is sinking input; a sourcing sensor wired as if it were sinking gives a channel that never turns on.
  4. Verify the input voltage range against the actual field supply, not against the nominal 24 V. 10...31.2 V DC on the IB16 means a 32 V rail is outside the published range.
  5. Set the module's input filter and change-of-state configuration in the Logix Designer project before commissioning, so the first fault report is not a filtering artefact.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  1.15...1.85 mA  Voltage-dependent, and much lower than the IH16I's 1...3 mA — less burden on a battery circuit.
 Check 3  275 mA backplane  More than double the IH16I, because the time-stamping runs on the backplane side.
 Check 4  Input-to-input isolation  250 V basic between inputs and to the backplane.
 Check 5  Sequence of events is configured  The capture behaviour lives in the Logix Designer project, not in the wiring.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a 16-point input module of an earlier generation

The non-ISOE high-voltage module is 1756-IH16I: 90...146 V DC, 1...3 mA, 125 mA backplane.

The 10...55 V DC sequence-of-events module is 1756-IB16ISOE, 5.1 mA, 320 mA backplane.

For plain 110 V DC inputs without event capture, the IH16I is the lower-cost backplane choice.

Which ControlLogix EtherNet/IP module to specify

  • 1756-IB16 — 16 sinking inputs, 10...31.2 V DC, 10 mA max, backplane 100 mA at 5.1 V DC, reinforced isolation to the backplane.
  • 1756-IB16D — the diagnostic version, 10...30 V DC, 13 mA max, backplane 150 mA at 5.1 V DC, basic isolation.
  • 1756-IB16I — individually isolated inputs, 10...30 V DC, 10 mA max, backplane 135 mA at 5.1 V DC, isolation input-to-input.
  • 1756-IB32 — 32 sinking inputs in one slot, 10...31.2 V DC, 5.5 mA max, backplane 120 mA at 5.1 V DC.
  • 1756-IB16IF — fast peer-control input module, 10...30 V DC, 5 mA max, backplane 275 mA at 5.1 V DC.
  • 1756-IB16ISOE — sequence-of-events input, 10...55 V DC, 5.1 mA max, backplane 320 mA at 5.1 V DC.
  • 1756-TBNH / 1756-TBSH — the removable terminal block housings; the module needs one and it is ordered separately.

FAQ — 1756-IH16ISOE Sequence of Events 90-140V DC Input | Rockwell

What is the 1756-IH16ISOE?

A 16-point sequence-of-events input module for 90...140 V DC circuits, with 1.15 mA at 90 V DC and 1.85 mA at 140 V DC per input.

What is the backplane current?

275 mA at 5.1 V DC and 2 mA at 24 V DC.

How does it differ from the 1756-IH16I?

Lower voltage ceiling (140 V against 146 V), lower input current (1.15...1.85 mA against 1...3 mA) and higher backplane draw (275 mA against 125 mA) for event capture.

What isolation does it provide?

250 V continuous basic inputs-to-backplane and 250 V basic input-to-input.

Does it capture timestamps?

Yes — sequence-of-events capture is configured in the Logix Designer project.

What is the input current at 90 V DC?

1.15 mA, rising to 1.85 mA at 140 V DC.

Is there a conformal-coated version?

Yes — 1756-IH16ISOEK.

What documents cover it?

1756-IN062 for installation and specifications, 1756-TD002 for technical data and 1756-UM058 for the user manual.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-IH16ISOE. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)