Allen Bradley PLC 1756-A17 / 1756A17 supplier Allen Bradley PLC 1756-A17 / 1756A17 supplier Allen Bradley PLC 1756-A17 / 1756A17 supplier Allen Bradley PLC 1756-A17 / 1756A17 supplier Allen Bradley PLC 1756-A17 / 1756A17 supplier Allen Bradley PLC 1756-A17 / 1756A17 supplier Allen Bradley PLC 1756-A17 / 1756A17 supplier

Large Image :  Allen Bradley PLC 1756-A17 / 1756A17

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-A17 / 1756A17

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $485.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-A17 technical data PDF download 1756-A17 ControlLogix 17 Slot Chassis | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-A17 (also written 1756A17) is the largest chassis in the ControlLogix family: 17 slots, published minimum enclosure 76.2 x 91.4 x 20.3 cm (30 x 36 x 8 in.), operating range 0...60 °C (32...140 °F), country of origin United States.

It is a passive backplane. The supply is ordered separately: a single 1756-PA75 or 1756-PB75, or a redundant pair through a 1756-PSCA2 chassis adapter on a /B (AC) or /C (DC) chassis, with one 1756-CPR2 cable per supply.

The reason to choose a 17-slot rack is density, not slot count for its own sake: a whole line — controller, multiple network modules, dense digital and analogue banks — in one backplane. That removes cross-rack communication from the I/O path and puts every module on the same power budget.

The cost of that density is the enclosure: 76.2 x 91.4 cm is a large panel area, and the convection path through it has to be designed. At full capacity the chassis is also the family member most likely to exceed a single supply's rating, so the current budget is a design step, not a formality.

Published record: UPC 612598129294, active lifecycle, one year warranty, 2-D and 3-D drawings published, selection guide 1756-SG001.

1756-A4
4 slots, minimum enclosure 50.8 x 50.8 x 20.3 cm, UPC 612598129300
In stock
1756-A7
7 slots, minimum enclosure 50.8 x 60.9 x 20.3 cm, UPC 612598129317
In stock
1756-A10
10 slots, minimum enclosure 50.8 x 76.2 x 20.3 cm, UPC 612598129270
In stock
1756-A13
13 slots, minimum enclosure 60.9 x 76.2 x 20.3 cm, UPC 612598129287
In stock
1756-A17
17 slots, minimum enclosure 76.2 x 91.4 x 20.3 cm, UPC 612598129294
In stock

 Application
 Chassis / backplane
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-A17
 Communication
 —
 Display
 —
 Enclosure
 Open chassis, convection cooled
 Interface
 Backplane
 Mounting
 Panel, bracket supplied
 Number Of Channels
 —
 Standard
 CE, UL, cUL
 Sub Brand
 ControlLogix
 Type
 Chassis
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (chassis installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-A17 chassis view 1 product photograph 1756-A17 chassis view 2 product photograph 1756-A17 chassis view 3 product photograph

Where the module sits in a typical system

17 slots is a line-level rack: one chassis carrying the controller and all I/O for a machine, with network modules alongside. It is the configuration that keeps a large I/O count on one backplane instead of three.

It also concentrates the power design: one supply or one redundant pair feeds everything, so the current budget is a single calculation rather than three that interact through chassis-to-chassis links.

For a redundant build, a single 17-slot rack with a PA75R pair and one PSCA2 adapter protects the whole line with two supplies and two cables — a smaller parts count than three redundant 7-slot racks.

Commissioning in five steps

  1. Confirm the chassis series against the supply: a /B chassis takes the AC redundant pair, a /C chassis takes the DC pair, and a standard chassis takes one non-redundant supply. The compatibility table in 1756-IN620 is the authority for this.
  2. Mount the chassis on the panel using the bracket the chassis ships with, and leave the convection path open — the published minimum enclosure size is a volume requirement, not a clearance allowance.
  3. Install the power supply, then verify the backplane voltages at the supply terminals before any module is inserted. A wiring error found with an empty chassis costs a fuse; found with a loaded chassis it costs modules.
  4. Insert modules with the chassis de-energised, then check that every module seats flush. A module that stops half way leaves its backplane connector open.
  5. Record the slot assignment on the drawing. ControlLogix allows the controller and communication modules to be placed in the slots the design needs, so the drawing rather than convention is what a later technician will follow.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  Enclosure area  76.2 x 91.4 cm minimum. Field wiring, terminals, breakers and the convection path all live inside that area with the rack.
 Check 3  0...60 °C with convection  The rating holds only if the cabinet actually moves air. A sealed enclosure at full slot count is a heat problem, not a chassis problem.
 Check 4  Series suffix  /B for the AC redundant pair, /C for the DC pair — 1756-IN620 lists the combinations.
 Check 5  Service access  A 91.4 cm wide rack needs front access to every slot. Leave the door swing and the wiring gutter on the drawing, not in the field.

Slot and supply compatibility per Rockwell publication 1756-IN620 (ControlLogix Redundant Power Supply installation instructions) and 1756-UM001 (ControlLogix system user manual, chassis installation) and 1756-IN050.

Sizing the rack and upgrading the slot count

The next size down is 1756-A13 (13 slots, 60.9 x 76.2 cm, 0...60 °C); below that 1756-A10 and 1756-A7.

A 17-slot rack cannot be split in the field. If the line may be extended, the alternative is two smaller racks — which reintroduces cross-rack communication and two power budgets.

Supplies, adapter and cables are shared family parts, so rack replacement keeps them.

Which ControlLogix EtherNet/IP module to specify

  • 1756-A4 — 4 slots, minimum enclosure 50.8 x 50.8 x 20.3 cm; the smallest enclosure footprint of the family.
  • 1756-A7 — 7 slots, minimum enclosure 50.8 x 60.9 x 20.3 cm; the size most machine-level panels are built around.
  • 1756-A10 — 10 slots, minimum enclosure 50.8 x 76.2 x 20.3 cm.
  • 1756-A13 — 13 slots, minimum enclosure 60.9 x 76.2 x 20.3 cm, 0...60 °C published.
  • 1756-A17 — 17 slots, minimum enclosure 76.2 x 91.4 x 20.3 cm, 0...60 °C published.
  • Series suffix matters — /B chassis take the AC redundant pair (1756-PA75R x2 + 1756-PSCA2 + 1756-CPR2 x2); /C chassis take the DC redundant pair (1756-PB75R x2 + the same adapter and cables).
  • 1756-PA75 / 1756-PB75 — the single supplies used when redundancy is not required; ordered separately from the chassis.

FAQ — 1756-A17 ControlLogix 17 Slot Chassis | Rockwell

What is the 1756-A17?

The 17-slot ControlLogix chassis — the largest in the family, minimum enclosure 76.2 x 91.4 x 20.3 cm, 0...60 °C published, made in the United States.

Does it include a power supply?

No. Supplies are separate: 1756-PA75 or 1756-PB75, or a redundant pair with 1756-PSCA2 on a /B or /C chassis.

How many modules can it hold?

Seventeen, with the power supply in the leftmost position and the controller in a slot.

Will one supply be enough?

Not necessarily. Sum the published backplane currents of all modules; a dense 17-slot rack can exceed a single 75 W class supply.

What is the enclosure minimum?

76.2 x 91.4 x 20.3 cm (30 x 36 x 8 in.), with the convection path open and service access to every slot.

Which series takes redundancy?

/B for the AC pair, /C for the DC pair, per 1756-IN620.

What is the temperature rating?

0...60 °C (32...140 °F), dependent on the enclosure providing convection.

What is the UPC and origin?

UPC 612598129294, country of origin United States.

Are 3-D models available?

Yes — 2-D drawings and a 3-D STEP model are published for panel design.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-A17. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)