logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-L65 / 1756L65

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-L65 / 1756L65

China Allen Bradley PLC 1756-L65 / 1756L65 supplier
Allen Bradley PLC 1756-L65 / 1756L65 supplier Allen Bradley PLC 1756-L65 / 1756L65 supplier Allen Bradley PLC 1756-L65 / 1756L65 supplier Allen Bradley PLC 1756-L65 / 1756L65 supplier Allen Bradley PLC 1756-L65 / 1756L65 supplier

Large Image :  Allen Bradley PLC 1756-L65 / 1756L65

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-L65 / 1756L65

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $10485.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description

1756-L65 technical data PDF download ControlLogix 1756-L65 / 1756L65 32 MB Controller

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-L65 (also written 1756L65) is the largest-memory controller of the ControlLogix 5560 range: 32 MB of user memory in one chassis slot, with one RS-232 serial port and backplane access to the rack's communication and I/O modules. Rockwell lists it as discontinued since 1 June 2017 under the functional replacement category.

Everything else is the 5560 envelope: 478 KB of I/O memory, 128,000 digital and 4,000 analogue I/O points as maximums, 32 tasks with 100 programs per task, 250 controller connections, 1200 mA at 5.1 V DC plus 14 mA at 24 V DC, 3.5 W and 11.9 BTU/hr, and 30 V continuous basic isolation on the RS-232 port (1756-TD001S). Two published cautions travel with this part: the scan time of a project loaded in an L64 or L65 can be slower than the same project in the smaller 5560 controllers, and the L64 and L65 do not carry the ATEX certification the rest of the family holds.

1756-L61 ControlLogix 5560 controller, 2 MB user memory IN STOCK
1756-L62 ControlLogix 5560 controller, 4 MB user memory IN STOCK
1756-L63 ControlLogix 5560 controller, 8 MB user memory IN STOCK
1756-L65 ControlLogix 5560 controller, 32 MB user memory IN STOCK
1756-L63XT ControlLogix-XT 5560 controller, 8 MB, -25 to +70 C IN STOCK
1756-L61S GuardLogix 5560 safety controller, 2 MB IN STOCK
1756-L62S GuardLogix 5560 safety controller, 4 MB IN STOCK
1756-L63S GuardLogix 5560 safety controller, 8 MB IN STOCK

 Application
 Programmable Logic Controller
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-L65
 Communication
 Backplane (EtherNet/IP, ControlNet, DeviceNet, DH+, Remote I/O, SERCOS)
 Display
 Indicators (OK, RUN, I/O, FORCE, BATTERY, RS-232)
 Enclosure
 None (open-style)
 Interface
 1 RS-232 serial port
 Mounting
 Chassis
 Number Of Channels
 1
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Controller
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-UM001 (ControlLogix controller user manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-L65 controller product photograph 1756-L65 controller, second view product photograph 1756-L65 controller label product photograph

Where the module sits in a typical system

32 MB is the answer when a program is memory-bound rather than I/O-bound: recipe tables and product data held in the controller, historical logging, or a large sequential or batch program that was split across controllers on the smaller models.

Two consequences belong in the design review. Scan time for a project loaded in this controller can be slower than the same project in a smaller 5560 controller, so cycle-time budgets are re-measured rather than scaled. And the missing ATEX entry means a classified location needs a different part number, not an argument.

Commissioning in five steps

  1. Confirm the controller and chassis are on a supply that covers 1200 mA at 5.1 V DC plus 14 mA at 24 V DC, and that the battery is the one the series needs — 1756-BA1, BA1M or BATA for Series A, 1756-BA2 for Series B.
  2. Set the serial port before the first download: DF1 full duplex at the project's own settings is the default path for a programming terminal, and the port is RS-232 through a 1756-CP3 or 1747-CP3 cable.
  3. Load firmware that the project was written for, then download. A 5560 controller at an older revision rejects a project built at a newer one, so the revision is checked first.
  4. Insert the controller in any chassis slot — it is not restricted to slot 0 — and start the chassis before the I/O modules are expected online.
  5. Read the indicators after the first power-up: OK, RUN, I/O, FORCE, BATTERY and RS-232. A red I/O indicator with a running program is a module that did not come online, not a controller fault.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 OK  Flashing green  Power-up self-test in progress; wait for solid.
 OK  Red  Major fault or self-test failure. Read the fault in the project before any restart.
 RUN  Green solid  Program running.
 RUN  Red  Major fault latched; the program is stopped.
 I/O  Green solid  All configured I/O modules are communicating.
 I/O  Flashing green  One or more configured modules are not responding.
 I/O  Red  Faulted I/O connection; the program may still be running.
 FORCE  Amber  Forces enabled — a live wiring check is not valid while this is lit.
 BATTERY  Red  Battery low or missing; the project in RAM is not protected across a power cycle.
 RS-232  Green flashing  Serial activity on the programming port.

Indicator behaviour per Rockwell publication 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and 1756-IN050.

Replacing a 1756-ENBT

Discontinued on 1 June 2017, replacement category functional replacement. The successor in the 5570 family is the 1756-L73E for racks of similar size; above it the 5580 controllers carry more memory with a much higher CIP packet rate and an embedded Ethernet port.

The migration matters most for memory-bound projects: the tag and program sizes are re-checked against the new controller, the scan-time assumption is re-measured, and any hazardous-area requirement is re-read against the new part's certification list before the order is placed.

Which ControlLogix 5560 controller to specify

  • 1756-L61 — 2 MB user memory. Smallest 5560 controller; enough for a line with a few I/O modules and no motion.
  • 1756-L62 — 4 MB. One step up; the usual choice where a 2 MB program left no room for edits.
  • 1756-L63 — 8 MB. The workhorse of the 5560 range, and the one most installed bases are built around.
  • 1756-L65 — 32 MB. Largest 5560 memory; scan time for a project in this controller can be slower than the same project in the smaller 5560 models.
  • 1756-L63XT — the 5560 controller in the XT range, for -25…+70 °C panels.
  • 1756-L71 / L72 / L73 (5570) — the current family, 1 MB to 32 MB with USB and higher packet rates. The functional replacement path from the 5560 controllers.

FAQ — ControlLogix 1756-L65 / 1756L65 32 MB Controller

How much memory does the 1756-L65 have?

32 MB of user memory with 478 KB of I/O memory — the largest in the 5560 range — and maximums of 128,000 digital and 4,000 analogue I/O points (1756-TD001S, ControlLogix 5560 Controllers).

Does a bigger controller mean a faster scan?

Not here. Rockwell publishes that the scan time for a project loaded in a 1756-L64 or L65 controller can be slower than for the same project loaded in one of the other 5560 controllers, and points to publication 1756-RM087 for instruction execution times. Cycle-time budgets are therefore measured, not assumed.

Is the 1756-L65 discontinued?

Yes. Discontinuation date 1 June 2017, replacement category functional replacement; the current families are the 5570 (L71E/L72E/L73E) and 5580 (L81E…L85E).

Is it certified for hazardous locations in Europe?

The ATEX entry in 1756-TD001S states explicitly that the 1756-L64 and 1756-L65 controllers do not carry that certification, unlike the L61, L62 and L63. The Class I Division 2 listings (UL E194810, CSA LR69960C, FM) are still published, so North American Division 2 use is covered while European Zone 2 use is not.

How many connections does it support?

250 controller connections, shared by I/O connections, produced and consumed tags and every HMI or programming session on the controller.

What is its current draw and dissipation?

1200 mA at 5.1 V DC and 14 mA at 24 V DC, 3.5 W and 11.9 BTU/hr, one slot wide (1756-TD001S). The same as every other 5560 controller — the memory size does not change the slot budget.

Which chassis, supplies and battery apply?

1756-A4, A7, A10, A13 or A17, any slot, one slot wide; standard supplies 1756-PA50, PA72, PA75, PB50, PB72, PB75, redundant PA75R, PB75R or PSCA2. Battery 1756-BA2 for Series B, 1756-BA1/BA1M/BATA for Series A.

What are the environmental limits?

Operating 0…60 °C with 60 °C maximum surrounding air, storage -40…85 °C, 5…95% RH non-condensing, 2 g vibration at 10…500 Hz, 30 g operating and 50 g non-operating shock, CISPR 11 Class A, ESD 6 kV contact and 8 kV air, radiated RF 10 V/m 80…2000 MHz and 3 V/m 2000…2700 MHz, EFT ±4 kV at 5 kHz and surge ±2 kV line-earth on the RS-232 port, conducted RF 10 V rms 150 kHz…80 MHz (1756-TD001S).


Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) and 1756-UM001 (ControlLogix 5570 and 5560 Controllers User Manual) and the manufacturer's product page for 1756-L65. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)