Allen Bradley PLC 1756-L61S / 1756L61S

China Allen Bradley PLC 1756-L61S / 1756L61S supplier
Allen Bradley PLC 1756-L61S / 1756L61S supplier Allen Bradley PLC 1756-L61S / 1756L61S supplier Allen Bradley PLC 1756-L61S / 1756L61S supplier Allen Bradley PLC 1756-L61S / 1756L61S supplier Allen Bradley PLC 1756-L61S / 1756L61S supplier Allen Bradley PLC 1756-L61S / 1756L61S supplier Allen Bradley PLC 1756-L61S / 1756L61S supplier Allen Bradley PLC 1756-L61S / 1756L61S supplier

Large Image :  Allen Bradley PLC 1756-L61S / 1756L61S

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-L61S / 1756L61S

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $3765.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-L61S technical data PDF download GuardLogix 1756-L61S / 1756L61S 2 MB Safety Controller

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-L61S (also written 1756L61S) is the 2 MB member of the GuardLogix 5560 range: a ControlLogix controller with a safety task, used as a pair with the 1756-LSP safety partner. The pair occupies two chassis slots, the partner sitting immediately to the right of the primary, and together they reach SIL CL 3 / PL e / Category 4 — one project, safety and standard logic together (1756-TD001I Tables 14 and 18).

Memory is 2 MB of user memory plus 1 MB of safety memory, on top of 478 KB of I/O memory and the 128,000 digital / 4,000 analogue I/O ceiling. Current draw is 1200 mA at 5.1 V DC and 14 mA at 24 V DC per module, 3.5 W and 11.9 BTU/hr; isolation is 30 V continuous basic insulation from the RS-232 port to the system, type tested at 720 V DC for 60 s. Controller redundancy is not supported on any GuardLogix 5560 pair.

1756-L61S GuardLogix 5560 safety controller, 2 MB user / 1 MB safety IN STOCK
1756-L62S GuardLogix 5560 safety controller, 4 MB user / 1 MB safety IN STOCK
1756-L63S GuardLogix 5560 safety controller, 8 MB user / 3.75 MB safety IN STOCK
1756-L61 ControlLogix 5560 standard controller, 2 MB IN STOCK
1756-L63 ControlLogix 5560 standard controller, 8 MB IN STOCK
1756-L65 ControlLogix 5560 standard controller, 32 MB IN STOCK

 Application
 Safety Control (SIL 3 / PL e)
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-L61S
 Communication
 Backplane (EtherNet/IP, ControlNet, DeviceNet)
 Display
 Indicators (OK, RUN, I/O, FORCE, BATTERY, RS-232)
 Enclosure
 None (open-style)
 Interface
 1 RS-232 serial port
 Mounting
 Chassis
 Number Of Channels
 1
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Safety Controller
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-RM093 (GuardLogix safety reference manual). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-L61S GuardLogix controller product photograph 1756-L61S controller product photograph 1756-L61S controller label product photograph

Where the module sits in a typical system

The pair is specified where a machine has to reach SIL 3 or PL e while staying in the same controller as the standard logic: a press or a transfer line whose guarding, interlocks and standard sequencing are written in one project and share one tag database.

The 1 MB safety memory is the size limit for the safety program itself, separate from the 2 MB standard memory. Safety I/O is Guard I/O on EtherNet/IP or DeviceNet; the safety networks on this controller are EtherNet/IP, ControlNet and DeviceNet, and the safety language is relay ladder with safety application instructions only.

Commissioning in five steps

  1. Install the primary controller and the 1756-LSP safety partner as a pair: the partner goes in the slot immediately to the right of the primary, and the pair occupies two slots. A single controller in a chassis does not run the safety task.
  2. The safety partner is configured automatically — no IP address, no project of its own. The safety logic is in the primary controller's project, in a safety task that is set to its integrity level.
  3. Budget the chassis against 1200 mA at 5.1 V DC plus 14 mA at 24 V DC for each of the two modules, and check that the supply is one from the published list: 1756-PA72, PA75, PB72 or PB75.
  4. Read the safety status before validating: the project reports a safety-task signature and a partner status, and a missing or mismatched partner is a configuration fault, not a field-device fault.
  5. Lock and protect the safety memory only after the safety task has been functionally tested; once locked, the safety logic cannot be edited and the SIL 3 claim applies.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 OK  Red  Major fault or self-test failure; check the safety task status before any restart.
 RUN  Green solid  Program running, standard and safety tasks executing.
 RUN  Red  Major fault latched; the program is stopped.
 I/O  Green solid  All configured I/O modules are communicating.
 I/O  Flashing green  One or more configured modules are not responding.
 FORCE  Amber  Forces enabled in the standard task — a live wiring check is not valid while this is lit.
 BATTERY  Red  Battery low or missing; the project in RAM is not protected across a power cycle.
 Partner status  Per project  The safety partner is reported in the project, not by a front indicator: a missing or mismatched partner stops the safety task from validating.

Indicator behaviour per Rockwell publication 1756-UM020 (GuardLogix Controllers User Manual) and 1756-IN050.

Replacing a 1756-ENBT

The 1756-L61S belongs to the 5560 family, which Rockwell discontinued; the moving path is the GuardLogix 5570 pair — 1756-L71S with 1756-L7SP — or the 5580 safety controllers. That is a project migration: safety memory sizes change, the partner part number changes, and the safety signature is re-generated and re-validated.

Nothing about that migration is a like-for-like swap. A GuardLogix pair carries its safety task integrity level and its signature; both are re-established on the new hardware before the line is released again.

Which GuardLogix safety controller to specify

  • 1756-L61S + 1756-LSP — 2 MB user memory, 1 MB safety memory. Smallest GuardLogix 5560 pair.
  • 1756-L62S + 1756-LSP — 4 MB user memory, 1 MB safety memory.
  • 1756-L63S + 1756-LSP — 8 MB user memory, 3.75 MB safety memory. The largest 5560 safety pair; the one most SIL 3 cells were built around.
  • 1756-LSP — the safety partner; it is not a spare of the primary controller and cannot be used on its own.
  • 1756-L7xS + 1756-L7SP — the GuardLogix 5570 pairs, 2 to 8 MB user and 1.5 to 4 MB safety memory.

FAQ — GuardLogix 1756-L61S / 1756L61S 2 MB Safety Controller

Can a 1756-L61S run on its own?

No. A GuardLogix system is a dual-controller solution: a 1756-L6xS primary plus a 1756-LSP safety partner. The partner is part of the system, is configured automatically and needs no setup of its own, but without it the safety task does not run (1756-TD001I Table 14).

How much memory does the safety side have?

2 MB of user memory and 1 MB of safety memory, with 478 KB of I/O memory and the standard 128,000 digital / 4,000 analogue I/O ceiling (Table 18). The safety program is limited by its own 1 MB, not by the 2 MB standard memory.

Which SIL and PL does the pair reach?

SIL CL 3 per IEC 61508/EN 62061 and Category 4 / PL e per EN ISO 13849-1 when used as described in publication 1756-RM093. TÜV certifies the functional safety and UL certifies SIL CL 3 under file E256621 (Table 20).

What is the slot footprint?

Two slots: the primary controller plus the safety partner, which must sit in the slot immediately to the right of the primary. Any slot of 1756-A4, A7, A10, A13 or A17 accepts the pair as a unit.

Which power supplies and current draw apply?

1756-PA72, PA75, PB72 or PB75 — the redundant supply list is not published for the L6xS pair. Each module draws 1200 mA at 5.1 V DC and 14 mA at 24 V DC, 3.5 W and 11.9 BTU/hr, so the pair is budgeted twice.

Does the pair support controller redundancy?

No. Table 14 states controller redundancy as not supported for GuardLogix controllers. Redundancy and a safety task are not combined in this family.

What are the environmental limits and certifications?

Operating 0…60 °C with 60 °C maximum surrounding air, storage -40…85 °C, 5…95% RH non-condensing, 2 g vibration at 10…500 Hz, 30 g operating and 50 g non-operating shock, CISPR 11 Class A, ESD 6 kV contact and 8 kV air, radiated RF 10 V/m 80…2000 MHz and 3 V/m 2000…2700 MHz, EFT ±4 kV at 5 kHz and surge ±2 kV line-earth on the RS-232 port (Table 19). Certifications: c-UL-us UL E65584/E194810, CSA LR54689C/LR69960C, CE to 2004/108/EC and 2006/42/EC, C-Tick (now RCM), FM Class I Division 2, KC (Table 20).

Which networks carry safety data?

EtherNet/IP, ControlNet and DeviceNet, for both standard and safety communication. Safety field devices connect through Guard I/O modules on those networks; the RS-232 port is for programming and carries no safety data.


Data sources. Technical values on this page come from Rockwell publications 1756-TD001 (ControlLogix and GuardLogix Controller Specifications) and 1756-RM093 (GuardLogix Controller Systems Safety Reference Manual) and the manufacturer's product page for 1756-L61S. Values re-checked 15 November 2026.

Related numbers