Allen Bradley PLC 1756-LSC8XIB8I / 1756LSC8XIB8I

China Allen Bradley PLC 1756-LSC8XIB8I / 1756LSC8XIB8I supplier
Allen Bradley PLC 1756-LSC8XIB8I / 1756LSC8XIB8I supplier Allen Bradley PLC 1756-LSC8XIB8I / 1756LSC8XIB8I supplier Allen Bradley PLC 1756-LSC8XIB8I / 1756LSC8XIB8I supplier Allen Bradley PLC 1756-LSC8XIB8I / 1756LSC8XIB8I supplier Allen Bradley PLC 1756-LSC8XIB8I / 1756LSC8XIB8I supplier Allen Bradley PLC 1756-LSC8XIB8I / 1756LSC8XIB8I supplier

Large Image :  Allen Bradley PLC 1756-LSC8XIB8I / 1756LSC8XIB8I

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-LSC8XIB8I / 1756LSC8XIB8I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $644.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 2 PCS
Detailed Product Description

1756-LSC8XIB8I technical data PDF download ControlLogix 1756-LSC8XIB8I / 1756LSC8XIB8I Low-Speed Counter Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-LSC8XIB8I (also written 1756LSC8XIB8I) is the ControlLogix low-speed counter module: eight individually isolated 10…30 V DC inputs, each usable either as a standard input or as a counter-control input, with a 14 µs hardware delay and an optional filter up to 30,000 µs.

Published figures are 275 mA at 5.1 V DC and 3 mA at 24 V DC, 1.47 W total backplane power, 3.8 W dissipation at 60 °C and 12.97 BTU/hr, 6 kΩ maximum input impedance at 30 V DC, and a cyclic update time of 200 µs to 750 ms. Isolation is 250 V continuous reinforced from inputs to backplane and 250 V basic input to input, which is what makes the individual isolation on each channel usable in practice. The module is one slot wide, uses the 1756-TBCH or 1756-TBS6H terminal block, with temperature codes T4A (North America) and T4 (IEC) (1756-TD002N).

1756-LSC8XIB8I
8 isolated 10…30 V DC inputs, counter control, 275 mA at 5.1 V DC
In stock
1756-LSC8XIB8IK
Conformal-coated 1756-LSC8XIB8I, same specification
In stock
1756-HSC
2 counters, 1 MHz, 4 outputs, 300 mA at 5.1 V DC
In stock
1756-CFM
2 flowmeter channels, gate inputs, 300 mA at 5.1 V DC
In stock
1756-IB16
16 sinking inputs, 24 V DC, no per-channel isolation
In stock

 Application
 Low-speed counter / isolated input
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-LSC8XIB8I
 Communication
 EtherNet/IP
 Display
 Digital
 Enclosure
 None (open-style)
 Interface
 1756-LSC8XIB8I
 Mounting
 Chassis
 Number Of Channels
 1756-LSC8XIB8I
 Standard
 CCC,CE,CSA,C-TICK,CUL,GOST,KC,MARINE,NRTL,RCM,UL
Vendor attribute list — the current Rockwell certification record, with certificate and file numbers, is in the FAQ.
 Sub Brand
 ControlLogix
 Type
 Communication Module
 UNSPSC
 32151705

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-LSC8XIB8I module product photograph 1756-LSC8XIB8I, second view product photograph 1756-LSC8XIB8I, third view product photograph

Where the module sits in a typical system

The module is specified where the inputs are few but the wiring is awkward: eight points, each isolated, on one card. Typical cases are a mix of grounded and floating sensors in the same panel, or a small stand-alone machine where a full 16-channel input card would be half empty.

The counter-control function is what separates it from a plain input module. Each channel can be assigned to count or to gate a count, which covers low-rate totalising — flow pulses, index pulses, cycle counts — without taking a dedicated high-speed counter slot.

It is not a substitute for the 1756-HSC. The 14 µs hardware delay and the configurable filter put the usable pulse rate far below 1 MHz, so anything with a fast encoder or a high-rate meter belongs on the HSC or the CFM instead.

Commissioning in five steps

  1. Wire the field supply to the module's own voltage class: 10…30 V DC, sink or source, with a 24 V DC nominal; the inputs are individually isolated, so a grounded sensor on one channel does not create a common on the others.
  2. Set the input filter deliberately. The hardware delay is 14 µs nominal and 23 µs maximum, plus a user-configurable filter of 0 to 30,000 µs; a filter left at its maximum will miss counts that the hardware could have captured.
  3. Use the counter-control function per channel, not per module: each of the eight inputs can be a plain input or a counter control, and the assignment is made in the module configuration, not by wiring.
  4. Check the isolation claim against the circuit: 250 V continuous reinforced from inputs to backplane, 250 V basic input to input. That is what allows a mix of floating and grounded sensors in one module.
  5. Budget 275 mA at 5.1 V DC and 3.8 W of dissipation per module (1756-TD002N), and keep the minimum on-state current of 2 mA in mind when a sensor is specified.

Limits: inputs, filter, current and isolation

An input module has no display that explains a missed count; its limits are the numbers that decide what the channel can capture. Every row below is quoted from the module specification 1756-TD002N.

 Indicator  State  Meaning and first action
 Voltage class  10…30 V DC, sink or source  24 V DC nominal, with reverse polarity protection.
 Input delay  14 µs nominal, 23 µs maximum  Plus a user-configurable filter of 0 to 30,000 µs; the filter is what usually limits the usable count rate.
 Off-state limits  5 V DC maximum, 1.5 mA maximum  A sensor that leaks above this level reads as on.
 On-state current  2 mA minimum at 10 V DC, 5 mA maximum at 30 V DC  The minimum is the figure that rules out weak or long-lead sensors.
 Input impedance  6 kΩ maximum at 30 V DC  Sets the load the module puts on the field circuit.
 Backplane current and power  275 mA at 5.1 V DC, 3 mA at 24 V DC; 1.47 W  Dissipation 3.8 W at 60 °C, 12.97 BTU/hr.
 Isolation  250 V reinforced (inputs to backplane), 250 V basic (input to input)  Reinforced to the backplane is what distinguishes this module from a standard input card.
 Terminal block and slot  1756-TBCH or 1756-TBS6H; 1 slot  Electronic, software-configurable keying; open-style enclosure.

Inputs, filter, current draw, dissipation and isolation per Rockwell publication 1756-TD002N-EN-E (1756 ControlLogix I/O Modules Specifications) and 1756-IN050.

Replacing a module inside an installed panel

The 1756-LSC8XIB8IK is the same module with conformal coating, and is the replacement where the panel atmosphere rather than the function has changed.

Where the counting duty is fast, the 1756-HSC replaces this module with dedicated counter hardware; where the duty is only status monitoring, a 1756-IB16 or 1756-IB32 removes the cost per point.

Because the inputs are isolated channel by channel, replacing this module with a non-isolated input card changes the ground reference of every field circuit in that group, which is a wiring review, not a parts swap.

Which counter module to specify

  • 1756-LSC8XIB8I — eight individually isolated 10…30 V DC inputs, each usable as a standard input or as a counter control input, 275 mA at 5.1 V DC.
  • 1756-HSC — where the pulse rate is high: 1 MHz counting, dedicated A/B/Z inputs per counter and four outputs.
  • 1756-CFM — where the count is flow and a gate input opens the totalising window.
  • 1756-IB16ISOE — where the duty is timestamped sequence-of-events capture rather than counting.
  • 1756-IB16 — plain 16-channel sinking input, where no per-channel isolation and no counting are needed.

FAQ — ControlLogix 1756-LSC8XIB8I / 1756LSC8XIB8I Low-Speed Counter Module

How many inputs does the 1756-LSC8XIB8I have?

Eight individually isolated inputs, each configurable as a standard input or a counter-control input (1756-TD002N).

What input voltage does it accept?

10…30 V DC, sink or source, with a 24 V DC nominal and reverse polarity protection.

How fast can it count?

The hardware delay is 14 µs nominal and 23 µs maximum, plus a user-configurable filter of 0 to 30,000 µs, so the practical count rate is set by the filter chosen.

What backplane current does it draw?

275 mA at 5.1 V DC and 3 mA at 24 V DC, 1.47 W total backplane power.

What is the power dissipation?

3.8 W at 60 °C and 12.97 BTU/hr.

What isolation is specified?

250 V continuous reinforced insulation from inputs to backplane, and 250 V basic between inputs.

What terminal block does it use?

1756-TBCH or 1756-TBS6H, one slot wide, with electronic software-configurable keying.

What is the minimum on-state current?

2 mA at 10 V DC; the maximum on-state current is 5 mA at 30 V DC.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002 (1756 ControlLogix I/O Modules Specifications) and the manufacturer's product page for 1756-LSC8XIB8I. Values re-checked 16 November 2026.