The 1756-OX8I (also written 1756OX8I) is the ControlLogix isolated relay output module with eight normally-open and eight normally-closed contacts, arranged as two points per group and individually isolated. Where the 1756-OW16I offers sixteen single contacts, the OX8I offers eight changeover pairs — the module for circuits that need a definite released state as well as a made state.
It carries the same C300/R150 pilot duty and the same voltage-dependent contact rating as the OW16I: 1 A at 5…30 V DC, 0.5 A at 48 V DC, 0.22 A at 125 V DC, 1.5 A at 120 V AC, 0.75 A at 240 V AC. Backplane draw is lower — 100 mA at 5.1 V and 100 mA at 24 V, 2.9 W total — because there are eight output circuits rather than sixteen.
1756-OW16I |
16 N.O. isolated relay outputs, C300/R150 pilot duty |
In stock |
1756-OX8I |
8 N.O. + 8 N.C. isolated relay outputs, C300/R150 |
In stock |
1756-OB16I |
16 DC outputs, solid state, isolated |
In stock |
1756-OA16I |
16 AC outputs, individually isolated |
In stock |
1756-TBCH |
Removable terminal block, 36 terminals |
In stock |
Application |
Relay output, isolated contacts |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-OX8I |
Type |
Digital relay output module |
Sub Brand |
ControlLogix |
Mounting |
1756 ControlLogix chassis |
Number Of Channels |
8 N.O. + 8 N.C. |
Output Type |
NO or NO/NC, individually isolated |
Contact Rating |
1 A at 5…30 V DC, 0.5 A at 48 V DC, 0.22 A at 125 V DC |
AC Rating |
1.5 A at 120 V AC, 0.75 A at 240 V AC |
Pilot Duty |
C300/R150 |
Backplane Current |
100 mA at 5.1 V DC, 100 mA at 24 V DC |
Power Dissipation |
3.1 W max |
Thermal Dissipation |
10.57 BTU/hr |
Isolation Voltage |
250 V (continuous), basic insulation |
Terminal Block |
1756-TBCH or 1756-TBS6H |
Operating Temperature |
0…60 °C (32…140 °F) |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
Changeover contacts are an interlocking tool. A single OX8I point gives a panel both the energised path and the released path of one circuit, which is exactly what a safety-monitored interlock or a two-path valve control needs, and it does it without an external slave relay.
The two-points-per-group arrangement is the detail that matters at wiring time. Sixteen isolated contacts in eight groups means the isolation boundary sits between groups, not between every point, and the drawing has to respect that when a group shares a supply.
The relay nature of the module is the constraint on the other side. Published life is 300,000 operations into a resistive load and 100,000 into an inductive one, switching frequency is limited to one operation every three seconds at rated load, and minimum load is 10 mA per point — three figures that decide whether a relay belongs in the circuit at all.
A relay module has no interesting diagnostics: the contact is either made or it is not, and the published limits below are what decide whether it stays that way.
| Indicator | State | Meaning and first action |
| OUT n N.C. | Open | Normally-closed contact released; the two points act as a changeover pair. |
| Minimum load | 10 mA | Below this the contact may not wet; the circuit reads open while closed. |
| Contact life | 300k / 100k | Operations into a resistive / inductive load; plan replacement on the count, not on failure. |
| Switching rate | 0.3 Hz | One operation every three seconds at rated load is the published maximum. |
| OK | Green | Module is operating normally. |
Contact ratings, backplane figures and environmental limits per Rockwell publication 1756-TD002N-EN-E and 1756-IN050.
Contact welding, not electronics, is the usual end. The symptom is an N.C. point that will not re-close, or an N.O. point that stays made after the output goes off, and the module is the replacement item.
Check the inductive load before ordering the replacement. A contactor coil without suppression eats the 100,000-operation inductive rating quickly, and adding a suppressor to the coil is cheaper than a second module.
The module uses the 1756-TBCH or 1756-TBS6H terminal block; retaining the existing block and its wiring keeps the swap to a slot change.
What is the 1756-OX8I?
A ControlLogix isolated relay output module with 8 N.O. and 8 N.C. contacts in two-point groups.
How does it differ from the 1756-OW16I?
The OW16I has 16 single N.O. contacts; the OX8I has 8 changeover pairs.
What is the contact rating?
1 A at 5…30 V DC, 0.5 A at 48 V DC, 0.22 A at 125 V DC, 1.5 A at 120 V AC and 0.75 A at 240 V AC.
What is the minimum load?
10 mA per point.
How long do the contacts last?
300,000 operations into a resistive load and 100,000 into an inductive load.
What is the maximum switching frequency?
One operation every three seconds, 0.3 Hz, at rated load.
What does it draw from the backplane?
100 mA at 5.1 V DC and 100 mA at 24 V DC, 2.9 W total, 3.1 W maximum dissipation.
What is the output delay?
13 ms maximum off-to-on and on-to-off, with a mean bounce time of 1.2 ms.
Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - technical specifications, environmental specifications and certifications for 1756-OX8I and the manufacturer's product page for 1756-OX8I. Values re-checked 16 November 2026.