logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-OV16E / 1756OV16E

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OV16E / 1756OV16E

China Allen Bradley PLC 1756-OV16E / 1756OV16E supplier
Allen Bradley PLC 1756-OV16E / 1756OV16E supplier Allen Bradley PLC 1756-OV16E / 1756OV16E supplier Allen Bradley PLC 1756-OV16E / 1756OV16E supplier Allen Bradley PLC 1756-OV16E / 1756OV16E supplier Allen Bradley PLC 1756-OV16E / 1756OV16E supplier

Large Image :  Allen Bradley PLC 1756-OV16E / 1756OV16E

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OV16E / 1756OV16E

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $305.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-OV16E technical data PDF download 1756-OV16E ControlLogix 16 Point Sinking DC Output | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OV16E (also written 1756OV16E) is the 16-point sinking DC output module: 10...30 V DC, 1 A pilot duty (DC-13/SR) per point, 8 A maximum output, backplane 210 mA at 5.1 V DC and 2 mA at 24 V DC, isolation 250 V continuous basic outputs-to-backplane and 250 V basic output group-to-group, no isolation between individual outputs (1756-IN062).

Sinking is the point of this module. It switches the return, not the supply: the field device is fed +24 V and the module pulls its return to common. That is the arrangement many drive inputs, banks of relay coils and third-party sensor interfaces expect.

The rating is 1 A pilot duty (DC-13/SR), with an 8 A maximum output for the module. Sixteen points at 1 A would be 16 A, so the 8 A ceiling splits the load in practice — the same arithmetic as the OB16E but with a different switching polarity.

Group isolation is 250 V between output groups rather than 125 V, which is more than the sourced side of the family offers, and points inside a group share their return.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OV16E
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OV16E module product photograph 1756-OV16E label product photograph 1756-OV16E terminal side product photograph

Where the module sits in a typical system

Use the OV16E where the field device expects a switched return — a drive's discrete input block with a common-cathode arrangement, a bank of relays wired to +24 V, or a third-party I/O board that sinks its inputs.

Its 250 V group-to-group isolation suits panels with two separate 24 V feeds, and the sinking arrangement keeps the live side of the field wiring permanently fed rather than switched.

Where the load must be switched on the supply side, the sourcing OB16E or OB16I is the equivalent card with the opposite polarity.

Commissioning in five steps

  1. Compare the point current at the cabinet temperature, not at 25 °C. The OB32 publishes 500 mA at 50 °C and 350 mA at 60 °C, the OB16D 2 A at 30 °C and 1 A at 60 °C, and the fast outputs 2 A at 45 °C but only 1 A at 60 °C.
  2. Check the module total, not the sum of the point ratings. The OB32 caps at 16 A per module at 50 °C and 10 A at 60 °C no matter how many points are on.
  3. Read the isolation column per module before wiring mixed supplies. The OB8 has no output-to-output isolation, the OB16E publishes 125 V, and the OB16I and OB8EI publish 250 V.
  4. A DC output driving an inductive load needs a suppression device across the load or at the contactor coil; the module's output stage is protected against the published ratings, not against an unsuppressed coil.
  5. Where the load must be monitored, the diagnostic modules compare the commanded state with the measured output and report a mismatch; a load below the module's minimum load current will read as a fault rather than as a healthy off state.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  1 A per point  DC-13/SR pilot duty. A 2 A contactor coil does not belong here.
 Check 3  8 A module maximum  Sixteen points cannot all run at 1 A; the module total splits the load.
 Check 4  250 V group-to-group  Better group isolation than the sourcing OB16E, which publishes 125 V.
 Check 5  Return-path wiring  With a sinking output, verify that the field device's supply shares a reference with the module's return.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a DC output module of an earlier generation

For sourcing outputs at 1 A with 2 A inrush, 1756-OB16E is the equivalent card.

For 32 sinking points at 350 mA, 1756-OV32E doubles the density.

For 2 A sourcing outputs with 250 V reinforced isolation, 1756-OB16I publishes pilot duty at 24 V DC.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OB16I — 16 points at 2 A pilot duty with 250 V reinforced isolation to the backplane and 250 V output-to-output.
  • 1756-OB16E — 16 points, 10...31.2 V DC, 1 A per point and 2 A inrush, 125 V output-to-output isolation.
  • 1756-OB16D — 16 diagnostic outputs, 2 A at 30 °C derating to 1 A at 60 °C, 19.2...30 V DC.
  • 1756-OB16IS — 16 points at 24 V DC, 2 A pilot duty, 350 mA backplane.
  • 1756-OB16IEF and 1756-OB16IEFS — 16 fast outputs, 2 A at 45 °C on up to four channels, 1 A at 60 °C.
  • 1756-OB32 — 32 points, 500 mA per channel at 50 °C and 350 mA at 60 °C, 16 A module maximum.
  • 1756-OB8 and 1756-OB8EI — 8 points at 2 A pilot duty; the EI adds output-to-output isolation.
  • 1756-OG16 — 16 TTL-level outputs, 4.5...5.5 V DC, with a 5.5 V DC user supply.
  • 1756-OV16E and 1756-OV32E — sinking outputs for a shared positive supply.

FAQ — 1756-OV16E ControlLogix 16 Point Sinking DC Output | Rockwell

What is the 1756-OV16E?

A 16-point sinking DC output module, 10...30 V DC at 1 A pilot duty per point, 8 A maximum output.

What does sinking mean here?

The module switches the return path, so the field device is supplied with +24 V and the module pulls its return to common.

What is the per-point rating?

1 A pilot duty, DC-13/SR.

What is the module maximum?

8 A output.

How is it isolated?

250 V basic outputs-to-backplane and 250 V basic between output groups, with none between individual outputs.

What is the backplane current?

210 mA at 5.1 V DC and 2 mA at 24 V DC.

What is its temperature code?

T4 under the North American classification.

Which publication publishes the ratings?

1756-IN062, the ControlLogix DC digital I/O installation instructions.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OV16E. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)