Allen Bradley PLC 1756-OA8E / 1756OA8E

China Allen Bradley PLC 1756-OA8E / 1756OA8E supplier
Allen Bradley PLC 1756-OA8E / 1756OA8E supplier Allen Bradley PLC 1756-OA8E / 1756OA8E supplier Allen Bradley PLC 1756-OA8E / 1756OA8E supplier Allen Bradley PLC 1756-OA8E / 1756OA8E supplier Allen Bradley PLC 1756-OA8E / 1756OA8E supplier Allen Bradley PLC 1756-OA8E / 1756OA8E supplier

Large Image :  Allen Bradley PLC 1756-OA8E / 1756OA8E

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OA8E / 1756OA8E

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $565.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-OA8E technical data PDF download 1756-OA8E / 1756OA8E 8-Point AC Output, Electronic Fusing

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OA8E (also written 1756OA8E) is the 8-point AC output module with electronic fusing and a higher current rating than the diagnostic OA8D: 2 A per point at 60 °C and a 20 A surge per point.

Total backplane power is 7.02 W, dissipation 5.5 W at 60 °C (18.76 BTU/hr).

1756-EN2F CLX HI CAP EIP MOD - FBR IN STOCK
1756-EN2T ControlLogix Hi Capacity ENET/IP IN STOCK
1756-EN2TR 2-PORT CLX HI-CAP ENET/IP MODULE - TP IN STOCK
1756-EN2TRXT CLX ENET/IP Module - 2TP -X Envt IN STOCK
1756-EN2TSC EtherNet/IP Hi Prof Sngl Port VPN Bridge IN STOCK
1756-EN2TXT CLX ENET/IP MODULE - TP, X-ENVT IN STOCK
1756-EN3TR ControlLogix Ethernet Motion Module IN STOCK
1756-ENBT ControlLogix Communication Module IN STOCK
1756-EWEB ControlLogix Web Server Module IN STOCK
1756-EXT ControlLogix Backplane Extender IN STOCK
1756-HIST1G Historian ME 1 Gig in ControlLogix Rack IN STOCK
1756-HIST2G Historian ME 2 Gig in ControlLogix Rack IN STOCK
1756-HSC ControlLogix High-Speed Counter Module IN STOCK
1756-HYD02 ControlLogix Analog Combination Module IN STOCK

 Application
 AC digital output module
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OA8E
 Outputs
 8, electronic fusing
 Voltage Category
 120 V AC 50/60 Hz
 Operating Voltage Range
 74…132 V AC, 47…63 Hz
 Output Delay
 9.3 ms @ 60 Hz; 11 ms @ 50 Hz
 Backplane Power
 7.02 W
 Power Dissipation
 5.5 W @ 60 °C
 Thermal Dissipation
 18.76 BTU/hr
 Current per Point
 2 A @ 60 °C
 Current per Group
 4 A @ 30 °C, linear derating to 2 A @ 60 °C
 Current per Module
 8 A @ 30 °C, linear derating to 4 A @ 60 °C
 Surge Current per Point
 20 A for 43 ms, repeatable every 2 s @ 60 °C
 Off-state Leakage
 3 mA per point, max
 On-state Voltage Drop
 4 V peak @ 2 A
 Load Current, Min
 10 mA per point
 Slot Width
 1

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OA8E AC output module product photograph 1756-OA8E, second view product photograph 1756-OA8E, third view product photograph

Where the module sits on an AC output circuit

The choice between OA8D and OA8E is a current decision, not a feature decision. Both fuse electronically; the OA8E carries 2 A per point at 60 °C without the 1 A/30 °C starting point that halves on the diagnostic module.

Group current is still the binding limit: 4 A per group at 30 °C, 2 A at 60 °C, and 8 A per module at 30 °C falling to 4 A at 60 °C. Four points sharing a group cannot each run at 2 A in a warm panel.

The 20 A surge for 43 ms per point, repeatable every 2 s, is what makes this module usable on contactor coils and small motor starters where the OA8D's 8 A or 5 A surge is marginal.

On-state voltage drop is higher here, up to 4 V peak at 2 A, because the module carries twice the current. On a 120 V circuit that is a 3% loss and a real thermal item at the device, not at the module.

Off-state leakage remains 3 mA per point, with a 10 mA minimum load. The leakage is unchanged by the higher rating, so the same caution applies to small relays and indicator lamps.

Total backplane power of 7.02 W means this module is a slightly heavier load on the chassis than the diagnostic version, even though its per-point capability is double — worth noting when two cards are swapped during a retrofit.

Commissioning in five checks

  1. Choose D or E by current, not by feature name. Both fuse electronically; D gives diagnostics, E gives 2 A per point at 60 °C.
  2. Read the derating curve as part of the load calculation: 1 A at 30 °C is 0.5 A at 60 °C on OA8D.
  3. Treat a group of four points as one electrical unit. A short on one point takes the group out until the fault clears.
  4. Allow for 3 mA of off-state leakage per point when the load is a small relay or an indicator.
  5. Fit a 20-position RTB and keep field wiring off the 120 V AC module until the chassis is grounded and the supply is isolated.

Fusing trips and what they mean

Protection is electronic fusing per group of four points, and the current rating is a 60 °C figure: the group limit, not the point limit, decides how many devices can share a card.

 Indicator  State  Meaning and first action
 Output heats up at 60 °C panel temperature  —  Current per point derates with temperature: 1 A at 30 °C becomes 0.5 A at 60 °C on the diagnostic module.
 Output stays on with no command  —  Off-state leakage is up to 3 mA per point, enough to hold a small relay or a neon indicator energised.
 Diagnostic does not report a short  —  The short-circuit trip needs a fault current above the published minimum; a soft short below it looks like a normal load.

Backplane current, dissipation, derating and isolation per Rockwell publication 1756-TD002-EN-E and 1756-IN050.

Replacing a 1756-OA8E

Confirm the group and module current limits for the actual panel temperature.

Do not swap an OA8D for an OA8E to solve a fusing problem without checking whether the group limit is the real cause.

Recheck field devices that rely on low off-state leakage; leakage is unchanged at 3 mA per point.

Which module to specify

  • 1756-OA8D — diagnostic, electronic fusing per group of four, 1 A at 30 °C derating to 0.5 A at 60 °C.
  • 1756-OA8E — electronic fusing with 2 A per point at 60 °C and a 20 A surge rating.
  • 1756-OA8 — the non-diagnostic 8-point module in the same family.
  • 1756-OA16I — 16 individually isolated points where channel separation matters.
  • 1756-OW16I — relay output where the load is dry-contact rather than AC.

FAQ — 1756-OA8E / 1756OA8E 8-Point AC Output, Electronic Fusing

What is the 1756-OA8E?

An 8-point AC output module with electronic fusing and 2 A per point at 60 °C.

How much current can one point carry?

2 A at 60 °C.

What are the group and module limits?

4 A per group at 30 °C derating to 2 A at 60 °C; 8 A per module at 30 °C derating to 4 A at 60 °C.

What surge can it handle?

20 A for 43 ms per point, repeatable every 2 s.

How much backplane power does it use?

7.02 W total.

What does it dissipate?

5.5 W at 60 °C, 18.76 BTU/hr.

What is the on-state voltage drop?

Up to 4 V peak at 2 A.

How much off-state leakage?

3 mA per point maximum.

What minimum load is required?

10 mA per point.


Data sources. Technical values on this page come from Rockwell publications 1756-TD002 (ControlLogix I/O Modules Specifications) - the table for 1756-OA8E, including backplane current, dissipation and per-point derating and the manufacturer's product page for 1756-OA8E. Values re-checked 16 November 2026.