logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-OA16I / 1756OA16I

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OA16I / 1756OA16I

China Allen Bradley PLC 1756-OA16I / 1756OA16I supplier
Allen Bradley PLC 1756-OA16I / 1756OA16I supplier Allen Bradley PLC 1756-OA16I / 1756OA16I supplier Allen Bradley PLC 1756-OA16I / 1756OA16I supplier Allen Bradley PLC 1756-OA16I / 1756OA16I supplier Allen Bradley PLC 1756-OA16I / 1756OA16I supplier Allen Bradley PLC 1756-OA16I / 1756OA16I supplier

Large Image :  Allen Bradley PLC 1756-OA16I / 1756OA16I

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OA16I / 1756OA16I

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $445.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-OA16I technical data PDF download 1756-OA16I ControlLogix 16 Point Isolated AC Output | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OA16I (also written 1756OA16I) is the isolated 16-point AC output module: 120/240 V AC at 50/60 Hz, 2 A pilot duty, backplane 300 mA at 5.1 V DC and 2.5 mA at 24 V DC, 2 A per point at 30 °C derating linearly to 1 A at 60 °C, 5 A per module at 30 °C and 4 A at 60 °C, and a 20 A surge for 43 ms repeatable every 2 s (1756-IN064, 1756-UM058).

The derating is not a footnote — it is the design constraint. Rockwell's own worked example derates the point current at 0.033 A per °C above 30 °C: at 50 °C a 2 A point is worth 1.34 A, and the 5 A module total is worth 4.34 A. A panel at 50 °C therefore cannot use the 30 °C figures at all.

Motor starter capability at 120 V AC/60 Hz is the strongest in the family: 15 size 2 starters at 30 °C and 12 at 60 °C, 13 size 3 at 30 °C and 10 at 60 °C, 8 size 4 at 30 °C and 6 at 60 °C, and 5 size 5 at 30 °C and 4 at 60 °C — the only module in the published table that reaches size 4 and 5 at all.

Isolation and output features follow the AC output family: scheduled outputs synchronised within 16.7 seconds to the Coordinated System Time, per-point fault and program states, and electronic module keying. The module is not fused per point; a fused interface module is recommended for output protection.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OA16I
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OA16I module product photograph 1756-OA16I terminal side product photograph 1756-OA16I module view product photograph

Where the module sits in a typical system

The OA16I is the high-capability AC output: more current per point than the OA16's group-fused arrangement allows in practice, and the only published option for size 4 and 5 starters at reduced counts.

Because the point current derates with temperature, the module suits panels where the cabinet temperature is known and documented. Sizing it from the 30 °C column in a 55 °C enclosure is the most common mistake with this part.

Its 20 A surge rating covers most contactor and small-starter inrush, provided the surge is not repeated faster than every 2 s — a rapidly cycling output is a different thermal case.

Commissioning in five steps

  1. Confirm the load current against the module's per-point rating at the actual cabinet temperature, not at 30 °C. Above 30 °C the OA16I point current derates linearly at about 0.033 A per °C.
  2. Check inrush, not just running current. A contactor or motor starter that draws 1,225 VA inrush per line presents far more than its sealed current, and the module's surge rating is the number that has to cover it.
  3. Decide the fusing arrangement before wiring: the OA16 is mechanically fused per group at 3.15 A, the OA8 family is either electronically fused per point or unprotected, and a fused interface module is recommended where the module itself is unprotected.
  4. Set the fault state and program state per point in the module configuration, so a communication failure drives the outputs to the state the machine needs.
  5. For diagnostic modules, respect the minimum load current — the 1756-OA8D needs at least 10 mA in the on state or its diagnostics cannot sense the load.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  Module total, not just per point  5 A at 30 °C falls to 4 A at 60 °C. Sixteen points at 2 A each would be 32 A; the module total is the real ceiling.
 Check 3  Surge 20 A for 43 ms  Repeatable every 2 s. Check contactor and starter inrush against this figure, not against the steady-state rating.
 Check 4  Size 4 and 5 starters  This is the only module in the published table that lists them — 8 at 30 °C, 6 at 60 °C for size 4.
 Check 5  No per-point fusing  The module is unprotected per point; the OA8D and OA8E are the electronically fused options.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a AC output module of an earlier generation

The group-fused 16-point module is 1756-OA16, which has a 3.15 A group fuse and no size 4 or 5 starter capability.

The 8-point electronically fused diagnostic module is 1756-OA8D with a 10 mA minimum load.

For DC loads after a rectifier, 1756-OB16I is the DC counterpart with scheduled outputs.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OA16 — 16 triac outputs, 120/240 V AC at 0.5 A pilot duty, mechanically fused per group at 3.15 A, 1500 A interruption current.
  • 1756-OA16I — 16 isolated triac outputs, 2 A per point at 30 °C derating to 1 A at 60 °C, 5 A per module, 20 A surge.
  • 1756-OA8 — 8 triac outputs with the widest motor-starter table of the family, up to size 5 at reduced ambient.
  • 1756-OA8D — 8 diagnostic outputs, electronically fused per point, 10 mA minimum load.
  • 1756-OA8E — 8 outputs, electronically fused per point.
  • 1756-OW16I — 16 isolated relay contacts, 10...265 V, for loads an AC output will not switch.

FAQ — 1756-OA16I ControlLogix 16 Point Isolated AC Output | Rockwell

What is the 1756-OA16I?

A 16-point isolated AC output module, 120/240 V AC at 2 A pilot duty, 2 A per point at 30 °C derating to 1 A at 60 °C.

How does the current derate?

Linearly above 30 °C at about 0.033 A per °C: at 50 °C a 2 A point is rated 1.34 A.

What is the module total current?

5 A at 30 °C and 4 A at 60 °C.

What surge can it take?

20 A maximum for 43 ms, repeatable every 2 s at 60 °C.

How many size 5 starters can it drive?

5 at 30 °C and 4 at 60 °C at 120 V AC/60 Hz — the only module in the published table that reaches size 5.

Is it fused per point?

No. A fused interface module is recommended; the OA8D and OA8E are electronically fused per point.

What output voltage range?

120/240 V AC at 50/60 Hz, rated 2 A pilot duty; the 1756-UM058 design example quotes a wider 74...265 V AC operating range.

What is the backplane current?

300 mA at 5.1 V DC and 2.5 mA at 24 V DC.

What documents cover it?

1756-IN064 for installation and 1756-UM058 for the module manual and derating tables.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OA16I. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)