The 1756-OA16I (also written 1756OA16I) is the isolated 16-point AC output module: 120/240 V AC at 50/60 Hz, 2 A pilot duty, backplane 300 mA at 5.1 V DC and 2.5 mA at 24 V DC, 2 A per point at 30 °C derating linearly to 1 A at 60 °C, 5 A per module at 30 °C and 4 A at 60 °C, and a 20 A surge for 43 ms repeatable every 2 s (1756-IN064, 1756-UM058).
The derating is not a footnote — it is the design constraint. Rockwell's own worked example derates the point current at 0.033 A per °C above 30 °C: at 50 °C a 2 A point is worth 1.34 A, and the 5 A module total is worth 4.34 A. A panel at 50 °C therefore cannot use the 30 °C figures at all.
Motor starter capability at 120 V AC/60 Hz is the strongest in the family: 15 size 2 starters at 30 °C and 12 at 60 °C, 13 size 3 at 30 °C and 10 at 60 °C, 8 size 4 at 30 °C and 6 at 60 °C, and 5 size 5 at 30 °C and 4 at 60 °C — the only module in the published table that reaches size 4 and 5 at all.
Isolation and output features follow the AC output family: scheduled outputs synchronised within 16.7 seconds to the Coordinated System Time, per-point fault and program states, and electronic module keying. The module is not fused per point; a fused interface module is recommended for output protection.
1756-IB16 |
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293 |
In stock |
1756-IB16D |
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA |
In stock |
1756-IB16I |
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA |
In stock |
1756-IB16IF |
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA |
In stock |
1756-IB16ISOE |
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA |
In stock |
1756-IB32 |
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309 |
In stock |
1756-IC16 |
16 inputs, 30...60 V DC, backplane per 1756-IN062 |
In stock |
1756-IG16 |
16 TTL inputs, backplane per 1756-IN062 |
In stock |
1756-IV16 |
16 inputs, 48 V DC, backplane per 1756-IN062 |
In stock |
Application |
Discrete output |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-OA16I |
Communication |
Backplane (producer/consumer) |
Display |
— |
Enclosure |
None (open-style) |
Interface |
Removable terminal block |
Mounting |
Chassis slot |
Number Of Channels |
16 |
Standard |
CE, UL, CSA, RCM |
Sub Brand |
ControlLogix |
Type |
Digital Output Module |
UNSPSC |
— |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The OA16I is the high-capability AC output: more current per point than the OA16's group-fused arrangement allows in practice, and the only published option for size 4 and 5 starters at reduced counts.
Because the point current derates with temperature, the module suits panels where the cabinet temperature is known and documented. Sizing it from the 30 °C column in a 55 °C enclosure is the most common mistake with this part.
Its 20 A surge rating covers most contactor and small-starter inrush, provided the surge is not repeated faster than every 2 s — a rapidly cycling output is a different thermal case.
Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.
| Indicator | State | Meaning and first action |
| Check 2 | Module total, not just per point | 5 A at 30 °C falls to 4 A at 60 °C. Sixteen points at 2 A each would be 32 A; the module total is the real ceiling. |
| Check 3 | Surge 20 A for 43 ms | Repeatable every 2 s. Check contactor and starter inrush against this figure, not against the steady-state rating. |
| Check 4 | Size 4 and 5 starters | This is the only module in the published table that lists them — 8 at 30 °C, 6 at 60 °C for size 4. |
| Check 5 | No per-point fusing | The module is unprotected per point; the OA8D and OA8E are the electronically fused options. |
Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.
The group-fused 16-point module is 1756-OA16, which has a 3.15 A group fuse and no size 4 or 5 starter capability.
The 8-point electronically fused diagnostic module is 1756-OA8D with a 10 mA minimum load.
For DC loads after a rectifier, 1756-OB16I is the DC counterpart with scheduled outputs.
What is the 1756-OA16I?
A 16-point isolated AC output module, 120/240 V AC at 2 A pilot duty, 2 A per point at 30 °C derating to 1 A at 60 °C.
How does the current derate?
Linearly above 30 °C at about 0.033 A per °C: at 50 °C a 2 A point is rated 1.34 A.
What is the module total current?
5 A at 30 °C and 4 A at 60 °C.
What surge can it take?
20 A maximum for 43 ms, repeatable every 2 s at 60 °C.
How many size 5 starters can it drive?
5 at 30 °C and 4 at 60 °C at 120 V AC/60 Hz — the only module in the published table that reaches size 5.
Is it fused per point?
No. A fused interface module is recommended; the OA8D and OA8E are electronically fused per point.
What output voltage range?
120/240 V AC at 50/60 Hz, rated 2 A pilot duty; the 1756-UM058 design example quotes a wider 74...265 V AC operating range.
What is the backplane current?
300 mA at 5.1 V DC and 2.5 mA at 24 V DC.
What documents cover it?
1756-IN064 for installation and 1756-UM058 for the module manual and derating tables.
Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OA16I. Values re-checked 15 November 2026.