logo
Home ProductsAB ControlLogix I/O 1756

Allen Bradley PLC 1756-OA16 / 1756OA16

Customer Reviews
Welcome to PLC-VIP , Your online shop for Allen Bradley & Siemens PLC parts.

—— PLC-VIP.SHOP

We also wish to be able to continue doing good business with you and your company in the years to come. We are very thankful for that.

—— Rodrigo

I'm Online Chat Now

Allen Bradley PLC 1756-OA16 / 1756OA16

China Allen Bradley PLC 1756-OA16 / 1756OA16 supplier
Allen Bradley PLC 1756-OA16 / 1756OA16 supplier Allen Bradley PLC 1756-OA16 / 1756OA16 supplier Allen Bradley PLC 1756-OA16 / 1756OA16 supplier Allen Bradley PLC 1756-OA16 / 1756OA16 supplier Allen Bradley PLC 1756-OA16 / 1756OA16 supplier Allen Bradley PLC 1756-OA16 / 1756OA16 supplier Allen Bradley PLC 1756-OA16 / 1756OA16 supplier Allen Bradley PLC 1756-OA16 / 1756OA16 supplier Allen Bradley PLC 1756-OA16 / 1756OA16 supplier Allen Bradley PLC 1756-OA16 / 1756OA16 supplier Allen Bradley PLC 1756-OA16 / 1756OA16 supplier

Large Image :  Allen Bradley PLC 1756-OA16 / 1756OA16

Product Details:

Place of Origin: Made in USA
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-OA16 / 1756OA16

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $358.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-OA16 technical data PDF download 1756-OA16 ControlLogix 16 Point AC Output Module | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-OA16 (also written 1756OA16) is the 16-point AC triac output module: 120/240 V AC at 50/60 Hz, 0.5 A pilot duty, backplane 400 mA at 5.1 V DC and 2 mA at 24 V DC, mechanically fused per group at 3.15 A at 250 V AC slow blow with an interruption current of 1500 A and a Littelfuse H2153.15 fuse (1756-IN064, 1756-UM058).

The fusing arrangement is the characteristic that separates it from the rest of the AC output family. The module is fused per group with a physical fuse, where the OA8D and OA8E are electronically fused per point and the OA8 is not protected at all. A blown group fuse on an OA16 takes every point in that group out at once, which is a maintenance fact worth knowing before a panel goes into service.

Motor-starter capability is published per starter size at 120 V AC/60 Hz: 16 starters of size 0...1, 14 of size 2 (7 per group), 4 of size 3 (2 per group), and none of size 4 or 5. The group restriction on size 2 and 3 is a limit of the group fuse, not of the triac.

The module is part of the family that also carries the published AC output features: scheduled outputs synchronised within 16.7 seconds to the Coordinated System Time, per-point fault state and program state, and electronic software-configurable module keying.

1756-IB16
16 sinking inputs, 10...31.2 V DC 10 mA, backplane 100 mA, UPC 612598171293
In stock
1756-IB16D
16 diagnostic inputs, 10...30 V DC 13 mA, backplane 150 mA
In stock
1756-IB16I
16 isolated inputs, 10...30 V DC 10 mA, backplane 135 mA
In stock
1756-IB16IF
16 fast peer-control inputs, 10...30 V DC 5 mA, backplane 275 mA
In stock
1756-IB16ISOE
16 sequence-of-events inputs, 10...55 V DC 5.1 mA, backplane 320 mA
In stock
1756-IB32
32 sinking inputs, 10...31.2 V DC 5.5 mA, backplane 120 mA, UPC 612598171309
In stock
1756-IC16
16 inputs, 30...60 V DC, backplane per 1756-IN062
In stock
1756-IG16
16 TTL inputs, backplane per 1756-IN062
In stock
1756-IV16
16 inputs, 48 V DC, backplane per 1756-IN062
In stock

 Application
 Discrete output
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-OA16
 Communication
 Backplane (producer/consumer)
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Removable terminal block
 Mounting
 Chassis slot
 Number Of Channels
 16
 Standard
 CE, UL, CSA, RCM
 Sub Brand
 ControlLogix
 Type
 Digital Output Module
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN062 (DC digital I/O installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-OA16 module product photograph 1756-OA16 terminal side product photograph 1756-OA16 module view product photograph

Where the module sits in a typical system

The OA16 drives AC solenoids, contactor coils, small starters and indicator banks at 120 V AC or 240 V AC. Sixteen points on one module with a group fuse is the classic panel arrangement for a machine section.

Its published starter table makes it the practical choice up to size 3 with the per-group limits respected — two size 3 starters per group is the ceiling, so a panel with eight large starters needs four groups or a contactor interface.

Where a single output fault must not disturb its neighbours, the module's group fuse is the wrong arrangement, and the OA8D or OA8E with per-point electronic fusing is the correct one.

Commissioning in five steps

  1. Confirm the load current against the module's per-point rating at the actual cabinet temperature, not at 30 °C. Above 30 °C the OA16I point current derates linearly at about 0.033 A per °C.
  2. Check inrush, not just running current. A contactor or motor starter that draws 1,225 VA inrush per line presents far more than its sealed current, and the module's surge rating is the number that has to cover it.
  3. Decide the fusing arrangement before wiring: the OA16 is mechanically fused per group at 3.15 A, the OA8 family is either electronically fused per point or unprotected, and a fused interface module is recommended where the module itself is unprotected.
  4. Set the fault state and program state per point in the module configuration, so a communication failure drives the outputs to the state the machine needs.
  5. For diagnostic modules, respect the minimum load current — the 1756-OA8D needs at least 10 mA in the on state or its diagnostics cannot sense the load.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  Motor starter limits  14 size 2 but only 7 per group; 4 size 3 but only 2 per group. A group-based load plan is mandatory.
 Check 3  No size 4 or 5  The published table lists none for the OA16 — those starters need a different output arrangement, typically a contactor driven by the module.
 Check 4  0.5 A pilot duty  The output rating is pilot duty, not 2 A. Above half an amp per point, the OA16I is the module that publishes 2 A.
 Check 5  Fault state configuration  Per-point fault and program states are configured in the project; the default is off.

Specifications per Rockwell publication 1756-IN062 (ControlLogix DC Digital I/O Modules installation instructions); module behaviour per 1756-UM058 and technical data 1756-TD002 and 1756-IN050.

Replacing a AC output module of an earlier generation

The isolated output module is 1756-OA16I: 120/240 V AC at 2 A pilot duty, 2 A per point at 30 °C derating to 1 A at 60 °C, 5 A per module.

The 8-point diagnostic module is 1756-OA8D, electronically fused per point with a 10 mA minimum load.

For DC loads the equivalent is 1756-OB16E or 1756-OB16I, and for dry contacts 1756-OW16I at 10...265 V.

Which ControlLogix EtherNet/IP module to specify

  • 1756-OA16 — 16 triac outputs, 120/240 V AC at 0.5 A pilot duty, mechanically fused per group at 3.15 A, 1500 A interruption current.
  • 1756-OA16I — 16 isolated triac outputs, 2 A per point at 30 °C derating to 1 A at 60 °C, 5 A per module, 20 A surge.
  • 1756-OA8 — 8 triac outputs with the widest motor-starter table of the family, up to size 5 at reduced ambient.
  • 1756-OA8D — 8 diagnostic outputs, electronically fused per point, 10 mA minimum load.
  • 1756-OA8E — 8 outputs, electronically fused per point.
  • 1756-OW16I — 16 isolated relay contacts, 10...265 V, for loads an AC output will not switch.

FAQ — 1756-OA16 ControlLogix 16 Point AC Output Module | Rockwell

What is the 1756-OA16?

A 16-point AC triac output module, 120/240 V AC at 0.5 A pilot duty, backplane 400 mA at 5.1 V DC, mechanically fused per group at 3.15 A.

What fuse does it use?

A Littelfuse H2153.15, 3.15 A at 250 V AC slow blow, with 1500 A interruption current.

How many motor starters can it drive?

16 of size 0...1, 14 of size 2 with only 7 per group, 4 of size 3 with only 2 per group, and none of size 4 or 5, at 120 V AC/60 Hz.

What happens when a group fuse blows?

Every output in that group goes off. That is the consequence of group-level fusing, and the reason the per-point fused modules exist.

What output voltage range?

120/240 V AC at 50/60 Hz, rated 0.5 A pilot duty per point.

What is the backplane current?

400 mA at 5.1 V DC and 2 mA at 24 V DC, the highest of the AC output modules.

Is it protected per point?

No — the fusing is per group. A fused interface module is recommended where per-point protection is required.

Can I switch a 24 V AC load?

No. The published output rating is 120/240 V AC; the 74...265 V AC range in 1756-UM058 belongs to the OA16I design example, not to this module.

What documents cover it?

1756-IN064 for installation and 1756-UM058 for the module manual and the ratings tables.


Data sources. Technical values on this page come from Rockwell publications 1756-TD003 (ControlLogix Communication Modules Specifications), 1756-IN050 (1756 EtherNet/IP Communication Modules, installation instructions), 1756-UM004 (ControlLogix EtherNet/IP Network Devices User Manual) and the manufacturer's product page for 1756-OA16. Values re-checked 15 November 2026.

Related numbers

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)