Allen Bradley PLC 1756-PSCA2 / 1756PSCA2

China Allen Bradley PLC 1756-PSCA2 / 1756PSCA2 supplier
Allen Bradley PLC 1756-PSCA2 / 1756PSCA2 supplier Allen Bradley PLC 1756-PSCA2 / 1756PSCA2 supplier Allen Bradley PLC 1756-PSCA2 / 1756PSCA2 supplier Allen Bradley PLC 1756-PSCA2 / 1756PSCA2 supplier Allen Bradley PLC 1756-PSCA2 / 1756PSCA2 supplier

Large Image :  Allen Bradley PLC 1756-PSCA2 / 1756PSCA2

Product Details:

Place of Origin: Made in MEXICO
Brand Name: Rockwell
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1756-PSCA2 / 1756PSCA2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $108.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1756-PSCA2 technical data PDF download 1756-PSCA2 ControlLogix Redundant Power Chassis Adapter | Rockwell

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: PLC Automation

The 1756-PSCA2 (also written 1756PSCA2) is the chassis adapter of the ControlLogix redundant power supply system: a passive module that accepts one or two redundant supplies through 1756-CPR2 cables and feeds the single power connector on the chassis backplane. It carries no supply of its own — Rockwell states voltage and current ratings as not applicable because the adapter only routes power (1756-IN620, 1756-TD005).

What it does carry is the backplane current capacity: 15.0 A at 5.1 V DC, 2.8 A at 24 V DC, 4.0 A at 3.3 V DC and 1.5 A at 1.2 V DC, all of which pass through the adapter to the chassis. That is the ceiling for the whole rack regardless of how much the two supplies can produce, so a pair of 1756-PA75R supplies rated 13 A each still delivers at most 15 A at 5.1 V into the backplane.

The important limitation is printed in bold in the installation instructions: the redundant system accounts for operational anomalies in the power supply only — the chassis adapter and the power supply cables are excluded. A failed adapter, a loose CPR2 connector or a damaged cable takes the rack down just as a failed supply would.

Published data: operating temperature 0…60 °C, open-style enclosure, 5…95 % non-condensing humidity, 30 G operating shock, 2 G vibration at 10…500 Hz, wire category 3 on the 1756-CPR2 connections. The XT version, 1756-PSCA2XT, is the one rated -25…+70 °C and 250 V reinforced insulation.

1756-PA75R AC redundant supply, 120/240 V AC, 13 A at 5.1 V DC, 75 W IN STOCK
1756-PB75R DC redundant supply, 24 V DC, 13 A at 5.1 V DC, 75 W IN STOCK
1756-PAXT XT AC supply, 8 A at 5.1 V DC, 42 W at -25 to +70 C IN STOCK
1756-PBXT XT DC supply, 10 A at 5.1 V DC, 52 W at -25 to +70 C IN STOCK
1756-PAXTR XT AC redundant supply, 42 W, 0-60 C in a non-XT chassis IN STOCK
1756-PA75 Non-redundant AC supply, single, 13 A at 5.1 V DC, 75 W IN STOCK

 Application
 Chassis Power
 Brand Name
 Rockwell (Rockwell)
 Cat Num
 1756-PSCA2
 Communication
 —
 Display
 —
 Enclosure
 None (open-style)
 Interface
 Backplane, via 1756-PSCA2
 Mounting
 Remote, cable-connected
 Number Of Channels
 —
 Standard
 CE, UL, RCM, EAC, Morocco DOC
 Sub Brand
 ControlLogix
 Type
 Redundant Power Supply
 UNSPSC
 —

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN620 (redundant power supply instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1756-PSCA2 chassis adapter product photograph 1756-PSCA2 twin connectors product photograph 1756-PSCA2 label detail product photograph

Where the module sits in a typical system

The adapter is the piece that turns two independent supplies into one redundant feed. In a critical rack the two supplies are mounted remotely in the enclosure, cabled to the adapter in the chassis, and the adapter presents them to the backplane as one source.

Because the adapter is passive, it adds no conversion loss and no diagnostics of its own. Status comes from the supplies' solid-state relay annunciator contacts, wired by the user up to 10 m (32.8 ft), which is the only place a failing supply becomes visible before the rack stops.

The 15 A backplane capacity makes this a fit for medium racks. A rack that needs more than 15 A at 5.1 V is split across two chassis rather than pushed through one adapter — the supply pair can be oversized, the adapter cannot.

Commissioning in five steps

  1. Mount the two supplies remotely and land both on the 1756-PSCA2 chassis adapter: the adapter is a passive device and simply funnels power from one or two supplies into the single backplane power connector.
  2. Use the published cable — 1756-CPR2, 1756-CPR2D or 1756-CPR2U — and never connect or disconnect it while either backplane power source is energised: an arc at the connector is an explosion hazard in a classified area and wears the contacts.
  3. Wire the mains side with 2.5 mm² (14 AWG) 90 °C copper at 1.2 mm insulation maximum, tighten to 0.565 N·m (5 lb·in), and protect every ungrounded supply with a 15 A time-delay fuse.
  4. Keep annunciator wiring to 10 m (32.8 ft) maximum if you use the annunciator contacts, and note the wire categories: category 1 on the power ports and category 3 on the 1756-CPR2 connections.
  5. Commission by load: with both supplies healthy the pair shares the chassis current, so confirm the sharing before you rely on it. A single healthy supply must carry the entire chassis load — that is the design promise, not a margin.

Diagnostics: status indicators

Three bi-colour indicators plus the alphanumeric display cover almost every commissioning fault, so most problems are resolved at the panel without a laptop.

 Indicator  State  Meaning and first action
 Check 2  Rack current, not supply current  15.0 A at 5.1 V DC passes through the adapter. Adding supplies does not raise this limit; it only adds tolerance to a supply failing.
 Check 3  Cable part number  1756-CPR2 is the 0.91 m (3 ft) cable with a 12.7 cm bend radius. The CPR2D and CPR2U variants need 10.16 cm of free space beside the adapter, so check the enclosure before choosing them.
 Check 4  Power off before connecting  Connecting or disconnecting a CPR2 while either backplane source is energised can arc — an explosion risk in hazardous locations and a wear risk on the connector pins in any location.
 Check 5  Ambient  0…60 °C for this adapter. If the enclosure runs outside that window the part is 1756-PSCA2XT, and then the chassis and supply pairing has to be rechecked against the XT tables.
 Check 6  Spares strategy  Since the adapter is excluded from the redundancy claim, a spare 1756-PSCA2 belongs on the shelf alongside the spare supply — the adapter is the single point the two supplies share.

Installation checks per Rockwell publication 1756-IN620, which covers adapter mounting, cable seating, load sharing, fusing and the chassis compatibility table and 1756-IN050.

Replacing a 1756-ENBT

The XT counterpart is 1756-PSCA2XT: same function, -25…+70 °C operating range and 250 V reinforced insulation where this part lists the rating as not applicable. Mixing a standard adapter into an XT chassis gives up the temperature rating of the assembly.

The cables are consumables in this system and are ordered separately from both the supplies and the adapter: 1756-CPR2 (0.91 m), 1756-CPR2D and 1756-CPR2U. A replacement adapter without a cable will not complete the installation.

No other adapter substitutes for this part. The 1756-PSCA2 is the only chassis adapter listed for the 1756-PA75R/PB75R and 1756-PAXTR/PBXTR supplies in 1756-IN620.

Which ControlLogix redundant power supply to specify

  • 1756-PA75R — AC redundant supply, 120/240 V AC nominal, 5.1 V DC at 13 A, 75 W maximum, pairs into chassis A4/B…A17/B.
  • 1756-PB75R — DC redundant supply, 24 V DC nominal (18 V minimum at the input), 5.1 V DC at 13 A, 75 W maximum, pairs into chassis A4/C…A17/C.
  • 1756-PAXTR / 1756-PBXTR — the XT redundant pair; rated 0…60 °C only when mounted in a non-XT chassis.
  • 1756-PSCA2 / 1756-PSCA2XT — the passive chassis adapter the supplies feed; one per chassis, two supply cables land on it.
  • 1756-CPR2 — the 0.91 m (3 ft) redundant supply cable; also offered as 1756-CPR2D and 1756-CPR2U.
  • 1756-PA75 / 1756-PB75 — the non-redundant single supplies; same 75 W class, no second supply and no adapter.

FAQ — 1756-PSCA2 ControlLogix Redundant Power Chassis Adapter | Rockwell

What does the 1756-PSCA2 actually do?

It is a passive chassis adapter that funnels power from one or two ControlLogix redundant power supplies into the single power connector on the chassis backplane. It contains no supply and no conversion (1756-IN620).

Does it have voltage and current ratings of its own?

Rockwell lists voltage and current ratings as N/A for the adapter, but the backplane capacity that passes through it is 15.0 A at 5.1 V DC, 2.8 A at 24 V DC, 4.0 A at 3.3 V DC and 1.5 A at 1.2 V DC.

Does the adapter itself count as redundant?

No. The installation instructions state that the redundant system accounts for operational anomalies in the power supply only, and explicitly exclude the chassis adapter and the power supply cables. An adapter failure stops the rack.

Which cables connect it to the supplies?

1756-CPR2, 0.91 m (3 ft), with a 12.7 cm (5.0 in.) bend radius; or 1756-CPR2D / 1756-CPR2U, which need 10.16 cm (4.0 in.) of clearance beside the adapter. Cables are ordered separately.

Which supplies can be used with it?

1756-PA75R, 1756-PB75R, 1756-PAXTR and 1756-PBXTR, in any AC/DC mix. The chassis pairing follows the supply: PA75R for A4/B…A17/B, PB75R for A4/C…A17/C, and the XT redundant supplies only reach the XT chassis list.

What is the operating temperature?

0…60 °C for 1756-PSCA2. The -25…+70 °C version is 1756-PSCA2XT, which also carries 250 V reinforced insulation where the standard adapter lists isolation as not applicable.

Can I hot-swap a supply or a cable?

A supply can be replaced while the system runs, but connecting or disconnecting a 1756-CPR2 cable with either backplane source energised can arc — an explosion hazard in classified areas and a connector wear issue everywhere else. Remove power first.

What wiring category applies?

Wire category 3 on the 1756-CPR2 connections, per the published specifications. Annunciator wiring from the supplies is user-supplied and limited to 10 m (32.8 ft).

What environmental figures are published?

Open-style enclosure, 5…95 % non-condensing humidity, 30 G operating shock, 2 G vibration at 10…500 Hz, operating 0…60 °C.


Data sources. Technical values on this page come from Rockwell publications 1756-IN620 (ControlLogix Redundant Power Supply, installation instructions), 1756-IN619 (ControlLogix Power Supply installation instructions) and 1756-TD005 (ControlLogix power supply technical data) and the manufacturer's product page for 1756-PSCA2. Values re-checked 15 November 2026.