The 1756-PLS (also written 1756PLS) is the ControlLogix programmable limit switch module for packaging machinery: sixteen discrete inputs, sixteen sourcing 24 V DC outputs, and a direct resolver interface, in a module that occupies three contiguous chassis slots.
It exists because cam switching belongs next to the shaft, not in the controller. The module reads an 846-SJDA1CG-R3-C resolver, resolves shaft position in hardware, and fires the outputs against programmed limits — so the on/off points of a flight bar or a knife follow the shaft angle at scan rates a controller task cannot match.
1756-PLS |
Programmable limit switch, 16 in / 16 out, resolver, 3 slots |
In stock |
1756-HSC |
High-speed counter, 2 counters, 4 outputs |
In stock |
1756-CFM |
Configurable flowmeter, 2 flow inputs, 2 outputs |
In stock |
1756-LSC8XIB8I |
8 isolated low-speed counter inputs |
In stock |
846-SJDA1CG-R3-C |
Resolver used with the 1756-PLS |
In stock |
Application |
Programmable limit switch / resolver interface |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-PLS |
Type |
Programmable limit switch module |
Sub Brand |
ControlLogix |
Mounting |
1756 ControlLogix chassis, three contiguous slots |
Number Of Channels |
16 inputs, 16 outputs |
Input Type |
10…30 V DC sinking inputs, resolver feedback |
Resolver |
846-SJDA1CG-R3-C |
Output Type |
Sourcing 24 V DC, short-circuit protected |
Output Current |
1 A per point at 24 V DC, 0.5 A at 60 °C |
Minimum Load |
40 mA per point |
Isolation Voltage |
See 1756-TD002N group isolation table |
Slot Width |
3 |
Operating Temperature |
0…60 °C (32…140 °F) |
UNE |
Not published in 1756-TD002N |
UNSPSC |
32151705 |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
A programmable limit switch replaces a mechanical cam bank and its proximity switches. One resolver on the shaft, sixteen outputs in the rack, and the limits are numbers in a configuration instead of the physical position of a cam — which is why a changeover on a packaging line becomes a download rather than a mechanical rebuild.
The output stage is designed for the loads that sit in that cabinet: 24 V DC sourcing, 1 A per point at 30 °C, with electronic short-circuit protection that carries no status bit. The published derating is 16.7 mA per degree above 30 °C, so at 60 °C a point is rated 0.5 A. A panel that runs warm has half the drive current it was specified with.
The 40 mA minimum load per point is the number that catches retrofits. Old cam circuits often fed a 24 V DC input card drawing 5 to 10 mA; on a PLS output that load is below the holding current and the input drops out intermittently as the cabinet temperature moves.
Three contiguous slots is a planning constraint rather than an electrical one. It changes the rack layout, the terminal block arrangement and often the enclosure width, so it has to be settled at the drawing stage — a PLS cannot be squeezed into a single spare slot later.
Resolver wiring follows the module, not the resolver data sheet alone. Sine, cosine and reference pairs land on the left-side terminals, the eight discrete inputs on the left and the sixteen outputs on the right in four groups of four, each group with its own DC power and common.
Commissioning is mostly a wiring exercise: confirm the resolver pairs, confirm each output group has its own 24 V feed, and then confirm the limits against the shaft with a slow manual rotation rather than a first production run.
There is no indicator bank to read: the published output behaviour, the 40 mA minimum load and the temperature derating are the diagnostic facts for this module.
| Indicator | State | Meaning and first action |
| Short circuit | Output drops | Electronic protection with no fault indicator; remove the load and toggle the point to restore. |
| Reverse polarity | Outputs disabled | Current-limited protection; a mis-wired output can be permanently disabled. |
| Resolver | No position | Check the sine, cosine and reference pairs at the left-side terminals before replacing the module. |
| Slot map | Three slots | A module that will not fit the planned slot is a chassis layout problem, not a fault. |
Output, resolver and environmental figures per Rockwell publication 1756-TD002N-EN-E; module operation per 1756-UM002 and 1756-IN050.
Position faults are usually resolver wiring. Before replacing the module, verify the sine, cosine and reference pairs at the terminals, and check the resolver coupling has not slipped on the shaft.
Output faults split two ways: a point that will not switch a load is a minimum-load or derating problem, and a point that stays on is a shorted field circuit that the electronic protection has already disabled.
Because the module spans three slots, a replacement needs the same slot map and the same terminal blocks; photograph the wiring before removal rather than trusting the drawing.
What is the 1756-PLS?
A ControlLogix programmable limit switch module with 16 inputs, 16 outputs and a resolver interface.
How many chassis slots does it need?
Three contiguous slots.
Which resolver does it use?
846-SJDA1CG-R3-C.
What is the output rating?
1 A per point at 24 V DC at 30 °C, derated by 16.7 mA per degree above 30 °C to 0.5 A at 60 °C.
What is the minimum load per point?
40 mA.
How is short-circuit protection reported?
It is electronic with no fault indication; remove the load and toggle the output to restore it.
What happens if an output is wired in reverse?
Protection is current limited, and a mis-wired output can be permanently disabled.
What are the environmental limits?
0…60 °C operating, -40…85 °C storage, 5…95% relative humidity non-condensing, 2 g vibration at 10…500 Hz, 30 g operating shock.
Data sources. Technical values on this page come from Rockwell publications 1756-TD002N (1756 ControlLogix I/O Modules Specifications, November 2021) - 1756-PLS technical and environmental specifications; 1756-UM002 (ControlLogix Programmable Limit Switch Module User Manual) and the manufacturer's product page for 1756-PLS. Values re-checked 16 November 2026.