Product Details:
Payment & Shipping Terms:
|
The 1756-PH75 (also written 1756PH75) is the standard ControlLogix supply for a 125 V DC input — 90…143 V DC nominal — with 75 W output, 13 A at 5.1 V DC and 2.8 A at 24 V DC.
It is the supply used in switchgear and substation cabinets, where 125 V DC is the station control voltage and the PLC sits on the same battery as the protection relays.
| 1756-EN2F | CLX HI CAP EIP MOD - FBR | IN STOCK |
| 1756-EN2T | ControlLogix Hi Capacity ENET/IP | IN STOCK |
| 1756-EN2TR | 2-PORT CLX HI-CAP ENET/IP MODULE - TP | IN STOCK |
| 1756-EN2TRXT | CLX ENET/IP Module - 2TP -X Envt | IN STOCK |
| 1756-EN2TSC | EtherNet/IP Hi Prof Sngl Port VPN Bridge | IN STOCK |
| 1756-EN2TXT | CLX ENET/IP MODULE - TP, X-ENVT | IN STOCK |
| 1756-EN3TR | ControlLogix Ethernet Motion Module | IN STOCK |
| 1756-ENBT | ControlLogix Communication Module | IN STOCK |
| 1756-EWEB | ControlLogix Web Server Module | IN STOCK |
| 1756-EXT | ControlLogix Backplane Extender | IN STOCK |
| 1756-HIST1G | Historian ME 1 Gig in ControlLogix Rack | IN STOCK |
| 1756-HIST2G | Historian ME 2 Gig in ControlLogix Rack | IN STOCK |
| 1756-HSC | ControlLogix High-Speed Counter Module | IN STOCK |
| 1756-HYD02 | ControlLogix Analog Combination Module | IN STOCK |
Application |
Chassis power supply, DC input |
Brand Name |
Rockwell (Rockwell) |
Cat Num |
1756-PH75 |
Type |
ControlLogix standard power supply |
Sub Brand |
ControlLogix |
Mounting |
Left end of 1756 chassis |
Input Voltage |
90…143 V DC, nominal 125 V DC |
Input Power |
95 W maximum |
Output Power |
75 W at 0…60 °C |
Current At 5.1 V |
13 A |
Current At 24 V |
2.8 A |
Current At 3.3 V |
4 A |
Current At 1.2 V |
1.5 A |
Inrush Current |
30 A maximum |
Hold-Up |
50 ms at 90…143 V DC |
Isolation |
250 V reinforced, tested 3500 V DC for 60 s |
Chassis |
1756-A4, A7, A10, A13, A17; series B, C |
Wire Size |
2.5 mm² (14 AWG), 90 °C minimum |
Terminal Torque |
0.565 N·m (5 lb·in) |
Weight |
0.95 kg (2.10 lb) |
Dimensions |
14.0 x 11.2 x 14.5 cm |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1756-TD003 (module specifications) and 1756-IN050 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
The input window is 90…143 V DC. A 125 V station battery floats near 135 V and drops towards 105 V during a discharge, both inside the window; the 90 V floor is what protects the chassis during a deep discharge test, and it is the number to check against the battery's duty curve rather than the nominal 125 V.
Feeding the controller from the station battery removes an AC-to-DC conversion stage that a substation would otherwise need, and it keeps the PLC alive on the same ride-through as the protection scheme. That is the practical reason the PH75 exists.
Output is 75 W total, with 13 A at 5.1 V and 2.8 A at 24 V shared against it. On a 125 V DC panel a common mistake is to expect the higher input voltage to deliver more backplane power — it does not; only the input side changes.
Hold-up is 50 ms at 90…143 V DC nominal input, published in milliseconds like the other DC units.
Isolation is 250 V continuous, reinforced, type tested at 3500 V DC for 60 seconds. On a station battery that is not bonded to earth at the panel, this is the barrier that keeps the backplane reference independent of the battery's ground-fault detection.
Inrush is 30 A maximum. The supply mounts at the left end of a 1756-A4, A7, A10, A13 or A17 chassis in series B or C, and takes 2.5 mm² (14 AWG) 90 °C wire at 0.565 N·m.
A power supply carries no diagnostic display of its own; the useful evidence is the input voltage under load, the total chassis wattage and the published hold-up at the site voltage.
| Indicator | State | Meaning and first action |
| Chassis browns out on a load step | Voltage dip | The 75 W output budget is shared by all rails; an added 24 V load can exhaust it before the 5.1 V current limit is reached. |
| Supply restarts on a short | Inrush | Inrush is 20 A on the AC unit and 30 A on the DC unit; confirm the upstream breaker tolerates repeated energisation. |
| Hold-up shorter than expected | — | Hold-up is published in cycles at a stated input and load, not as a fixed millisecond figure. |
Input, output and hold-up figures per Rockwell publication 1756-TD005-EN-E and 1756-IN050.
Read the battery voltage during a discharge test, not at float. A 125 V battery at 135 V float can fall under 100 V under load, and the margin to the 90 V floor is what matters.
Check the chassis series — the PH75 fits series B or C only.
Verify the input fusing and DC isolation on the panel before swapping a supply; on a station battery an unexpected second ground shows up as a supply fault.
What is the 1756-PH75?
A standard ControlLogix DC power supply for a 125 V DC nominal input, 75 W output.
What input voltage range does it accept?
90…143 V DC, nominal 125 V DC.
What current is available at 5.1 V DC?
13 A.
What is the total output power?
75 W at 0…60 °C.
What is the hold-up time?
50 ms at 90…143 V DC nominal input.
What is the maximum inrush current?
30 A.
Which chassis does it fit?
1756-A4, A7, A10, A13 and A17 in series B or C.
Is it suitable for a station battery?
Yes — the 90…143 V window covers a 125 V battery from float to deep discharge, and isolation is 250 V reinforced.
Data sources. Technical values on this page come from Rockwell publications 1756-TD005 (ControlLogix Power Supplies Specifications) - input, output, hold-up, isolation and environmental data for 1756-PH75; 1756-SG001 (ControlLogix System Selection Guide) - chassis and supply selection and the manufacturer's product page for 1756-PH75. Values re-checked 16 November 2026.