Allen Bradley PLC 1734-IV4 / 1734IV4 supplier Allen Bradley PLC 1734-IV4 / 1734IV4 supplier Allen Bradley PLC 1734-IV4 / 1734IV4 supplier Allen Bradley PLC 1734-IV4 / 1734IV4 supplier Allen Bradley PLC 1734-IV4 / 1734IV4 supplier Allen Bradley PLC 1734-IV4 / 1734IV4 supplier Allen Bradley PLC 1734-IV4 / 1734IV4 supplier Allen Bradley PLC 1734-IV4 / 1734IV4 supplier Allen Bradley PLC 1734-IV4 / 1734IV4 supplier

Large Image :  Allen Bradley PLC 1734-IV4 / 1734IV4

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1734-IV4 / 1734IV4

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $29.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1734-IV4 technical data PDF download POINT I/O 1734-IV4 / 1734IV4 4-Channel 24V DC Sourcing Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O DC Input Module

The 1734-IV4 is the sourcing counterpart of the 1734-IB series: instead of sinking current from a powered sensor, it feeds the input circuit from field power and expects the sensor to pull that point low. 4 points on one slice, 24V DC nominal.

That direction matters at commissioning. A sourcing input is wired to a sinking sensor or a dry contact to common, and reversing the two is the single most common cause of a slice that reads all eight points ON.

1734-IV4 4 sourcing 24V DC inputs, 2...15 mA per point, 31.8 g IN STOCK
1734-IV8 8 sourcing 24V DC inputs, 1.2 W dissipation, 32.3 g IN STOCK
1734-IB4D 4 sinking 24V DC inputs with open-wire and short circuit diagnostics IN STOCK

Product Specifications 1734-IV4 (PDF)
 Number of inputs
 4 (1 group of 4), sourcing
 Voltage, on-state, nom
 24V DC
 Voltage, on-state range
 11...28.8V DC
 Voltage, off-state range
 -3...+5V DC
 Current, on-state range
 2...15 mA
 Current, off-state, max
 1.5 mA
 Input filter time
 0.5 ms hardware plus 0...65 ms selectable
 POINTBus current, max
 75 mA @ 5V DC
 Power dissipation, max
 1.0 W @ 28.8V DC
 Thermal dissipation, max
 3.4 BTU/hr @ 28.8V DC
 Isolation voltage
 50V (continuous), reinforced insulation, type tested at 2500V DC for 60 s, field side to system
 External DC power supply
 None required - the module sources its inputs from field power
 Terminal base
 1734-TB or 1734-TBS
 Keyswitch position
 1
 Dimensions, HxWxD
 56 x 12 x 75.5 mm
 Weight, approx
 31.75 g
 Temperature, operating
 -20...55 deg C (-4...131 deg F), T4A

Same-family catalog numbers: 1734-IV8. Each of those catalogue numbers has its own stock page on this store; this page covers what differs in the 1734 family.

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-SG001E-EN-P (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-IV4 original product photograph, wide view 1734-IV4 original product photograph, label view 1734-IV4 original product photograph, second unit

Sourcing is not a preference, it is a wiring direction

With a sourcing input the module supplies the wetting current and the field device sinks it. A PNP sensor drops straight in; an NPN sensor will not, and neither will a sinking-output photoeye. Decide the sensor family before ordering the slice, because the two directions are not field-convertible.

11V to 28.8V is the usable window

On-state starts at 11V DC, off-state is guaranteed between -3V and +5V DC. The upper bound is 28.8V, so a nominal 24V supply with normal tolerance is inside the window and a 30V rail is not. Reverse polarity on the field supply is handled by the module, but a sustained 30V still sits above the rating.

2 to 15 mA per point

On-state current range 2...15 mA, off-state leakage up to 1.5 mA. The 2 mA floor is what wets a dry contact; a sensor that only sources 500 uA may never cross it, which reads as a stuck-off point. Leakage above 1.5 mA from a failed sensor or a long shielded run reads as a stuck-on point.

Filter and heat

0.5 ms hardware filter plus a 0...65 ms selectable digital window. The hardware stage is short enough for a counter-style signal at low speed; the digital stage is the debounce for mechanical contacts. Dissipation is 1.0 W @ 28.8V DC per slice at 28.8V DC - 3.4 BTU/hr @ 28.8V DC BTU/hr - and the slice draws 75 mA from the 5V POINTBus.

Where a sourcing slice earns its place

Panels that already run PNP sensors, or that feed inputs from a common positive rail, save the interposing relays and the extra terminal blocks when they use 1734-IV4 instead of a sinking slice. The isolation is 50V reinforced, type tested at 2500V DC for 60 s, the same envelope as the IB family, so replacing an IB slice with an IV slice does not change the panel's segregation plan.

FAQ — 1734-IV4

What is a sourcing input?

The module supplies the wetting current from field power and the field device sinks it to common. PNP sensors wire directly; NPN sensors do not.

What voltage range does 1734-IV4 accept?

24V DC nominal, on-state 11...28.8V DC, off-state guaranteed from -3V to +5V DC.

How much current does each point need?

Between 2 and 15 mA in the on state, with a maximum of 1.5 mA leakage in the off state.

Which base fits 1734-IV4?

1734-TB or 1734-TBS at keyswitch position 1, drawing 75 mA from the 5V POINTBus.

How does it differ from 1734-IB4?

Direction of current only: IB4 sinks, IV4 sources. Voltage window, filter time and the 50V reinforced isolation are the same family values.


Data sources. Technical values on this page come from Rockwell publication 1734-SG001E-EN-P (POINT I/O Modules Selection Guide) and 1734-UM001. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.

Related numbers

1734 1734-IV4: 4-point sink/source DC input

1734-IV4 is a 4-point sink/source DC input in the POINT I/O family. It mounts on a terminal base assembly that is ordered separately, connects to the POINTBus through the base, and presents its field wiring on the removable terminal block.

AttributeValue
Catalog number1734-IV4
Module type4-point sink/source DC input
POINTBus current requirement75 mA
Module width12.1 mm (0.48 in.) standard, 24.1 mm (0.94 in.) for safety modules
Terminal baseOrdered separately: 1734-TB/TBS (8 terminal) or 1734-TB3/TB3S (12 terminal)
Module dimensions77.5 x 12.1 x 56.6 mm (3.05 x 0.48 x 2.23 in.), weight approx. 31-36 g

POINTBus current is the budget that decides how many modules a slice can carry: most digital and analog modules draw 75 mA, the 1734-OW2 draws 80 mA, and 1734-IB4D draws 50 mA. The usable current of the adapter, plus that of any expansion power supply, divided by the per-module draw gives the maximum slice length, and that is a planning calculation rather than a rule of thumb.

Every POINT I/O module mounts in a terminal base that is ordered separately, and the number of field terminals on the base has to match the module: eight terminals for single-point-per-channel digital modules, twelve where the module needs a common or a shield return per channel group.

Sink/source and AC-input variants exist because the field device decides the wiring, not the module preference: a sinking input expects the field device to switch to the positive rail, a sourcing input expects it to switch to common, and an isolated AC input exists so that a shared common between channels does not create a path between two different field circuits.

Ordering discipline for this family is the practical point: the module alone does not make a working channel, because the terminal base assembly is a separate catalog number, the RTB is a separate replacement part, and the head unit sets how many modules the slice can carry.

Mechanically the system is width-driven: adapters occupy 56.1 mm, expansion power supplies and field power distributors 25.4 mm each, standard I/O modules 12.1 mm each, and safety I/O modules 24.1 mm each. Total panel width is the sum of those, and a layout that assumes a uniform module width is wrong on both the adapter and the safety side.

The Allen-Bradley POINT I/O 1734 modules category groups the other catalog numbers, options and spare parts in the same range.

Contact Details
PLC-VIP SHOP

Contact Person: Miss. linda

Tel: 00-852-65626925

Fax: 00-852-90164956

Send your inquiry directly to us (0 / 3000)