Allen Bradley PLC 1734-IM2 / 1734IM2

China Allen Bradley PLC 1734-IM2 / 1734IM2 supplier
Allen Bradley PLC 1734-IM2 / 1734IM2 supplier Allen Bradley PLC 1734-IM2 / 1734IM2 supplier Allen Bradley PLC 1734-IM2 / 1734IM2 supplier Allen Bradley PLC 1734-IM2 / 1734IM2 supplier Allen Bradley PLC 1734-IM2 / 1734IM2 supplier Allen Bradley PLC 1734-IM2 / 1734IM2 supplier Allen Bradley PLC 1734-IM2 / 1734IM2 supplier Allen Bradley PLC 1734-IM2 / 1734IM2 supplier Allen Bradley PLC 1734-IM2 / 1734IM2 supplier

Large Image :  Allen Bradley PLC 1734-IM2 / 1734IM2

Product Details:

Place of Origin: Made in SINGAPORE
Brand Name: PLC Module
Certification: All goods we supply are 100% original factory sealed with 1 year warranty!
Model Number: Allen Bradley PLC 1734-IM2 / 1734IM2

Payment & Shipping Terms:

Minimum Order Quantity: 1 /PCS
Price: $39.00 (USD/PCS)
Packaging Details: 100% original new
Delivery Time: IN STOCK; 4-6 weeks for ordering
Payment Terms: Paypal, T/T and Western Union.
Supply Ability: 5 PCS
Detailed Product Description

1734-IM2 technical data PDF download POINT I/O 1734-IM2 / 1734IM2 2-Channel AC Input Module

Category: PLCs, Power Supplies & I/Os
Manufacturer: Rockwell
Group: POINT I/O AC Input Module

The 1734-IM2 takes 2 nonisolated sinking AC inputs on one slice, 8.5 mA at 220V AC. No external relay or interface card is needed between a 120V or 220V field contact and the POINTBus.

Because the input is sinking and nonisolated, all points share one common and the field supply must come from a source that matches the module voltage class exactly: 159V AC...264V AC.

1734-IA2 2 sinking 120V AC inputs, 65...132V AC, 7.5 mA at 120V IN STOCK
1734-IA4 4 sinking 120V AC inputs, 65...132V AC, 30.9 g IN STOCK
1734-IM2 2 sinking 220V AC inputs, 159...264V AC, 8.5 mA at 220V IN STOCK
1734-IM4 4 sinking 220V AC inputs, 159...264V AC, 30.9 g IN STOCK

Product Specifications 1734-IM2 (PDF)
 Number of inputs
 2 (1 group of 2), nonisolated, sinking
 Voltage, on-state, nom
 220V AC
 Voltage, on-state range
 159V AC...264V AC
 Voltage, off-state, max
 43V AC
 Current, on-state, nom
 8.5 mA @ 220V AC, 60 Hz
 Current, on-state range
 6.2 mA @ 159V AC...10.2 mA @ 264V AC, 60 Hz
 Impedance, input, nom
 22.3 kOhm
 Input filter time
 20 ms hardware filter plus 1...65 ms digital filter, programmable in 1 ms steps
 POINTBus current, max
 75 mA @ 5V DC
 Power dissipation, max
 0.48 W @ 264V AC
 Thermal dissipation, max
 1.63 BTU/hr @ 264V AC
 Isolation voltage
 240V (continuous), type tested at 3250V DC for 60 s, field side to system
 External AC power supply
 220V AC @ 60 Hz, 159...264V AC, 47...63 Hz
 Terminal base
 1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS
 Wiring category
 1 - on signal ports
 Keyswitch position
 8
 Dimensions, HxWxD
 56.0 x 12.0 x 75.5 mm
 Weight, approx
 30.9 g
 Temperature, operating
 -20...55 deg C (-4...131 deg F), T4A

Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-SG001E-EN-P (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.

1734-IM2 original product photograph, wide view 1734-IM2 original product photograph, label view 1734-IM2 original product photograph, second angle

Voltage window and off-state guard

On-state range 159V AC...264V AC, off-state guaranteed below 43V AC. That gap is what keeps a 120V circuit from reading a stray 40V induced level as a valid ON, and it is the reason this module tolerates long field wiring runs next to contactor coils.

Input current sets the load on the field device

Nominal 8.5 mA @ 220V AC, 60 Hz, with a working range of 6.2 mA @ 159V AC...10.2 mA @ 264V AC, 60 Hz. A dry contact or a small pilot relay has to carry that current reliably at the low end of the range; a sealed reed rated for switching only 1 mA may not wet properly, so check the device's minimum load before dropping a 2-point slice into a panel full of low-current sensors.

Filter: 20 ms hardware plus a digital window

Every Series C AC input slice carries a 20 ms hardware filter, then a digital filter from 1 to 65 ms set in 1 ms steps. Twenty milliseconds is already longer than a half cycle at 60 Hz, so the hardware stage alone rejects most contact bounce; the digital stage is for a noisy bus, not for speed. Do not expect this slice to catch a 10 ms pulse.

Supply, isolation and base

External supply 220V AC @ 60 Hz, 159...264V AC, 47...63 Hz. Isolation is 240V continuous, type tested at 3250V DC for 60 s from field side to system - the highest test level in the POINT I/O digital family, which is what a 220V circuit demands. The slice fits a TB, TBS, TOP or TOPS base at keyswitch position 8 and dissipates 0.48 W @ 264V AC.

Cost per point versus a DC slice

A 2-point AC slice removes four or eight interposing relays, their DIN rail, and the wiring between relay coil and input. On a panel that switches 120V pushbuttons and level switches directly, the saving is real; on a panel already built around 24V DC, stay with a DC slice and keep one voltage class in the cabinet. The four AC input slices share one 30.9 g moulding and one keyswitch position, so keeping a single spare on the shelf covers 2 and 4 point duties in either voltage class.

FAQ — 1734-IM2

What is the difference between 1734-IM2 and 1734-IA2?

Voltage class only: IM2 is 220V AC nominal from 159V AC to 264V AC, IA2 is 120V AC nominal from 65V AC to 132V AC. Both are two-point nonisolated sinking slices with a 20 ms hardware filter.

Can 1734-IM2 be used on a 120V circuit?

No. 159V AC is the lowest on-state voltage; a 120V signal never guarantees an ON state.

What current does each point draw at 220V?

8.5 mA nominal, 6.2 mA at 159V AC and 10.2 mA at 264V AC.

What isolation does it provide?

240V continuous, type tested at 3250V DC for 60 s, field side to system; the two points are not isolated from each other.

Which base does it need?

1734-TB, 1734-TBS, 1734-TOP or 1734-TOPS at keyswitch position 8, with a 220V AC external supply.


Data sources. Technical values on this page come from Rockwell publication 1734-SG001E-EN-P (POINT I/O Modules Selection Guide) and 1734-UM001. Any attribute the publication does not print is marked Not published rather than taken from a distributor page. Catalog number, packaging and stock status are the stock record of this listing.