Product Details:
Payment & Shipping Terms:
|
The 1734-IB4 is the four-channel POINT I/O Series C sink input module. All four points sit in one common group on a single 12 mm slice, which is the usual choice for a station that needs a small cluster of sensors: four proximity switches on a transfer, four limit switches on a fixture, or the feedback set of a two-position valve.
It produces one byte of input data, consumes nothing, and shares the same electrical window as the other Series C sink inputs: 10...28.8V DC on-state, 5V DC maximum off-state, 4 mA typical on current.
| 1734-IB2 | 2 sinking 24V DC inputs, one group of 2, 30.9 g | IN STOCK |
| 1734-IB4 | 4 sinking 24V DC inputs, one group of 4, 31.8 g | IN STOCK |
| 1734-IB8 | 8 sinking 24V DC inputs, one group of 8, 32.3 g | IN STOCK |
On-state voltage, min |
10V DC |
On-state voltage, nominal |
24V DC |
On-state voltage, max |
28.8V DC |
On-state current, min |
2 mA |
On-state current, nominal |
4 mA @ 24V DC |
On-state current, max |
5 mA |
Off-state voltage, max |
5V DC |
Off-state current, min |
1.5 mA |
Input impedance, nominal |
3.6 kΩ |
Input impedance, max |
4.7 kΩ |
Input filter time |
0.5 ms hardware plus 0...63 ms, user-selectable, both directions |
POINTBus current, max |
75 mA @ 5V DC |
Isolation voltage |
50V (continuous), Reinforced Insulation, tested 2500V DC for 60 s, field side to system |
Field power supply, nominal |
24V DC |
Field power voltage range |
10...28.8V DC |
Dimensions, HxWxD |
56 x 12 x 75.5 mm |
Terminal base screw torque |
0.8 Nm (7 lb-in) |
Mounting base |
1734-TB or 1734-TBS wiring base assembly |
Keyswitch position |
1 |
Temperature code |
T4A (North American), T4 (IEC) |
Operating temperature |
-20...55 °C |
Enclosure |
None (open style) |
Inputs per module |
4 (1 group of 4), sinking |
Power dissipation, max @ 28.8V DC |
1.0 W @ 28.8V DC |
Thermal dissipation, max @ 28.8V DC |
3.4 BTU/hr @ 28.8V DC |
Input status indicators |
4, yellow, logic side |
Weight, approx |
31.8 g |
Attribute values above are reproduced from the manufacturer's product data. For the authoritative technical record see Rockwell publications 1734-IN051H-EN-E (module specifications) and 1734-UM001 (installation instructions). Certification details, with certificate and file numbers, are listed in the FAQ below.
A 1734-IB4 draws 75 mA at 5V DC from POINTBus and dissipates 1.0 W at 28.8V DC, or 3.4 BTU/hr. That is a third of the thermal load of an eight-point slice, so a cabinet that is already tight on adapter power budget can add two four-point modules for close to the heat of one eight-point module while keeping the point count the same.
Terminals 0 to 3 are inputs 0 to 3, terminal 4 and 5 are common, and terminals 6 and 7 are user supply. A 2-wire sinking sensor returns to the common terminal and a 3-wire sensor takes its supply from 6 or 7. Because the four points share one common group, keep the field devices on a common reference - a mixed-source cluster will defeat the shared common.
Both directions use 0.5 ms hardware filtering, and a per-module 0...63 ms software filter can be added. Sequence-of-events work benefits from leaving the software filter at zero and letting the controller timestamp the byte, while mechanical contacts benefit from 4 to 10 ms of software filtering to suppress bounce.
Four yellow indicators show each point, one module status LED and one network status LED report the slice. Flashing green means the module is online but not yet configured, solid green means the connection is established. Per-point diagnostics are not available on this module.
The three modules differ only in point count, POINTBus current is the same 75 mA, and the dissipation scales with the count. Choose the smallest module that covers the station so spare points do not consume adapter power and cabinet heat without being used.
Does the 1734-IB4 consume output data from the scanner?
No. The module produces one byte of input data (scanner Rx) and consumes no I/O data (scanner Tx), so the adapter's output image is not used by this module.
What is the input filter time and can it be changed?
0.5 ms of hardware filtering applies in both directions, plus a user-selectable 0...63 ms software filter. The default configuration uses the hardware filter only, so set the software value in the module's configuration when contact bounce or noise is present.
Which terminal base does the 1734-IB4 need?
It mounts on a 1734-TB or 1734-TBS wiring base assembly with a removable terminal block. Terminal base screw torque is 0.8 Nm (7 lb-in).
Can I use 2-wire and 3-wire proximity switches?
Yes. Sink inputs accept 2-wire and 3-wire sinking devices; on 3-wire switches connect the common to terminal 4 (1734-IB2/IB4) and take 12/24V DC from the internal power bus or from terminals 6/7.
What field voltage range can the inputs tolerate?
Field power is 24V DC nominal and the published range is 10...28.8V DC. On-state voltage is 10V DC minimum, 24V DC nominal and 28.8V DC maximum; off-state voltage must stay at or below 5V DC.
How much current does a 1734-IB4 draw from the adapter?
75 mA at 5V DC maximum on POINTBus. Dissipation is 1.0 W and 3.4 BTU/hr at 28.8V DC.
The table reproduces the sibling list this page publishes, with each catalog number put in the class of module it is; the paragraph after it places this part in that ladder, and the arithmetic at the end uses this page's own POINTBus figure against the 1.0 A budget the adapters print.
| Catalog number | What the published line says | Class of module |
| 1734-IB2 | 2 sinking 24V DC inputs, one group of 2, 30.9 g | Digital input |
| 1734-IB4 | 4 sinking 24V DC inputs, one group of 4, 31.8 g | Digital input |
| 1734-IB8 | 8 sinking 24V DC inputs, one group of 8, 32.3 g | Digital input |
1734-IB4 is the middle of the three sinking input modules, and the family axis is points per milliamp: all three print 75 mA on the POINTBus, so the 2-point 1734-IB2 costs 37.5 mA per point and the 8-point 1734-IB8 costs 9.4. The published input ladder - 10 V on, 5 V off, 4 mA at 24 V - is the same on all three.
At the 75 mA this module prints, the 1.0 A POINTBus carries 13 modules with nothing left over. A full 63-module rack of this module would be 4725 mA, 4.7 times the 1.0 A budget, so the 63-module figure is a slot count and the current is what decides how many expansion supplies go into the rack.
The class column is the useful filter: within one page the list holds modules that look alike in a catalog and behave completely differently on a backplane, and the printed one-line description is the only place the difference appears.
What the printed data does not carry: this page prints the sibling descriptions but not their POINTBus currents, so the 75 mA is the only draw in the table that can be used; and no page in this family states a maximum number of modules between two power supplies.
Source: Rockwell publication 1734-IN001 (POINT I/O module and adapter installation instructions) and the module specification tables published on these pages; the class column and the module count are read off the printed lines, not assumed.
Related models, options and spare parts for this range are listed in the Allen-Bradley POINT I/O 1734 modules category.